The Two-Photon Mass Resolution Measured by RadPhi

R.T. Jones
University of Connecticut, Storrs, CT
and
Jefferson Lab, Newport News, VA.

June 20, 1997

Abstract

The translation from shower position and energy resolution in a calorimeter to the resolution in terms of two-cluster invariant mass depends upon the energy distribution of the photons and the target-detector geometry. Starting from the single-shower resolutions obtained with a similar calorimeter in the E852 experiment at Brookhaven, I estimate the width of the 0 mass peak that is expected for the RadPhi experiment. In the analysis I distinguish between position-resolution and energy-resolution contributions to the mass width, and show under what circumstances each may be seen to dominate the error.