Specification for tagging magnetic spectrometer
From GlueXWiki
Contents |
[edit]
Global Tagging Spectrometer Specification
| Main beam momentum | 12 GeV/c |
| Momenum range of analyzed electrons | 0.5 to 9 GeV/c |
| Main beam radius | 26.685 m |
| Main beam bending angle | 13.4° |
| Entrance face angle for the first magnet | 5.9° |
| Magnetic field (full excitation) | 15.0000 kG |
| Pole gap | 30 mm |
[edit]
Tagger Dipoles
| Length | 3.09 m |
| Width | 1.09 m |
| Height | 1.41 m |
| Weight | 38 Mg |
| Separation between magnets | 40 cm |
| Angle between magnets | 0.892° |
[edit]
Tagger Dipole Coils
| Total number of ampere turns for each magnet | 61560 |
| Copper conductor dimensions | 11 x 11 mm2 |
| Copper conductor hollow core | 7 mm diameter channel |
| Conductor configuration of each coil | 7 x 12 |
| Current density at nominal field | 4.44 A/mm2 |
| Electrical resistance of each coil | 0.124 |
| Current in conductor | 366.43 A |
| Voltage drop across 4 coils connected in series | 181.7 V |
| Total power consumption | 67 kW |
| Cooling circuits per coil | 7 |
| Total flow rate for 20◦C rise | 80 l/min |
| Water supply pressure drop | 2.0 atm |
| Outside dimension of each coil | 92 x 152 mm2 |
| Coil treatment | should be vacuum impregnated |
[edit]
Tagger Quadrupole Magnet
| Aperture diameter | 30 mm |
| Magnetic length | 400 mm |
| Max magnetic field gradient | 20 T/m |
| Alignment of magnetic and geometric axes | ±0.05 mm |
[edit]
Tagger Magnet Power Supply
| Power output | 80 kW |
| Lead voltage | 200 V |
| Current | 400 A |
| Current stability | few parts per million over 48 hours |
| Options | zero field using a feed-back loop |