TOF Backgrounds

From GlueXWiki

Jump to: navigation, search

Back to Background Rate Studies


Detector Configuration

  • Geometry as of January 15, 2007
  • Double-Hit Resolution: 25 ns
  • Threshold: 0.8 MeV
  • Maximum Number of Hits: 100

Items for Discussion

  • There seem to be no hits for bars 41-44. Software bug?

Yes, it was a mismatch between the names used in the hdds geometry document and those expected in the simulation hits package. This bug was fixed by RTJ on 16-Jan.

Plots

The characteristic background rate per PMT per bar in the TOF.
The characteristic background rate per PMT per bar in the TOF.
The energy deposition in the TOF for background hits.  There are no surprises here -- log( 2.54 cm * 0.002 GeV / cm ) = -2.3
The energy deposition in the TOF for background hits. There are no surprises here -- log( 2.54 cm * 0.002 GeV / cm ) = -2.3
Personal tools