Dose Calculation

From GlueXWiki

(Difference between revisions)
Jump to: navigation, search
Revision as of 20:18, 5 November 2009
Yvhaarle (Talk | contribs)

← Previous diff
Revision as of 20:19, 5 November 2009
Yvhaarle (Talk | contribs)

Next diff →
Line 20: Line 20:
* 1 year of running (= 1/3 year beam on target) = <math>1.1\cdot 10^{7}s \times 267 e/s\cdot cm \times 2\cdot 10^{5} = 9.0 \cdot 10^{-5} C/cm</math> * 1 year of running (= 1/3 year beam on target) = <math>1.1\cdot 10^{7}s \times 267 e/s\cdot cm \times 2\cdot 10^{5} = 9.0 \cdot 10^{-5} C/cm</math>
 +
 +* Irradiation dose = 44 years of running

Revision as of 20:19, 5 November 2009

Dose (C/cm):

\frac{\#e}{1cm} \cdot 1.60 \cdot 10^{-19} C/e \cdot gas gain


  • Lamina 300 A:

3.6\cdot10^{11}\times1.6\cdot10^{-19}\times2\cdot10^{5} = 0.01~C/cm

  • Lamina 12 μm:

1.2\cdot10^{11}\times1.6\cdot10^{-19}\times2\cdot10^{5} = 0.004~C/cm

  • CMU mylar:

1.4\cdot10^{11}\times1.6\cdot10^{-19}\times2\cdot10^{5} = 0.004~C/cm

  • CMU kapton:

2.9\cdot10^{11}\times1.6\cdot10^{-19}\times2\cdot10^{5} = 0.009~C/cm


EM background: 40~kHz/straw or 267~Hz/cm

  • 1 year of running (= 1/3 year beam on target) = 1.1\cdot 10^{7}s \times 267 e/s\cdot cm \times 2\cdot 10^{5} = 9.0 \cdot 10^{-5} C/cm
  • Irradiation dose = 44 years of running