Dose Calculation
From GlueXWiki
(Difference between revisions)
| Revision as of 20:22, 5 November 2009 Yvhaarle (Talk | contribs) ← Previous diff |
Revision as of 20:23, 5 November 2009 Yvhaarle (Talk | contribs) Next diff → |
||
| Line 19: | Line 19: | ||
| EM background: <math>40~kHz/straw</math>or <math>267~Hz/cm</math> | EM background: <math>40~kHz/straw</math>or <math>267~Hz/cm</math> | ||
| - | * 1 year of running (= 1/3 year beam on target) = <math>1.1\cdot 10^{7}s \times 267 s^{-1}\cdot cm^{-1} \times 1.60\cdot10^{-19} \times 2\cdot 10^{5} = 9.0 \cdot 10^{-5} C/cm</math> | + | * 1 year of running (= 1/3 year beam on target) = <math>1.1\cdot 10^{7}s \times 267 e/s\cdot cm \times 1.60\cdot10^{-19}C/e \times 2\cdot 10^{5} = 9.0 \cdot 10^{-5} C/cm</math> |
| * Irradiation dose = 44 years of running | * Irradiation dose = 44 years of running | ||
Revision as of 20:23, 5 November 2009
Dose (C/cm):
- Lamina 300 A:
- Lamina 12 μm:
- CMU mylar:
- CMU kapton:
EM background:
or
- 1 year of running (= 1/3 year beam on target) =
- Irradiation dose = 44 years of running