Regards, Reinhard.
***Wire Map Analysis for Region One***
_____________________________________________________________
Layer 01
Average Log # hits/channel = 1.41
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
38 8 40 0 6
39 8 44 0 6
Possible cable pull-out
_____________________________________________________________
Layer 02
Average Log # hits/channel = 1.39
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
20 8 21 1 6
37 8 41 0 6
38 8 45 0 6
51 8 73 1 6
78 9 37 0 6
109 9 89 0 6
_____________________________________________________________
Layer 03
Average Log # hits/channel = 1.39
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
37 8 42 0 6
38 8 46 0 6
Possible cable pull-out
56 8 94 1 6
72 9 14 1 6
78 9 38 0 6
_____________________________________________________________
Layer 04
Average Log # hits/channel = 1.41
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
15 8 7 1 6
20 8 3 0 6
36 8 43 0 6
37 8 47 0 6
Possible cable pull-out
49 8 71 0 6
58 8 83 1 6
77 9 39 0 6
_____________________________________________________________
Layer 05
Empty Layer
_____________________________________________________________
Layer 06
Empty Layer
_____________________________________________________________
Layer 07
Average Log # hits/channel = 1.37
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
70 6 12 0 6
109 7 30 1 6
_____________________________________________________________
Layer 08
Average Log # hits/channel = 1.40
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
68 6 11 0 6
78 6 47 1 6
82 6 47 0 6
116 7 59 0 6
_____________________________________________________________
Layer 09
Average Log # hits/channel = 1.36
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
69 6 13 0 6
88 6 55 0 6
_____________________________________________________________
Layer 10
Average Log # hits/channel = 1.39
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
26 4 76 1 6
67 6 10 0 6
_____________________________________________________________
Layer 11
Average Log # hits/channel = 1.40
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
29 4 92 1 6
57 5 68 0 6
67 6 8 0 6
68 6 14 0 6
_____________________________________________________________
Layer 12
Average Log # hits/channel = 1.39
Missing Hot Weak TDC TDC Mux ROC
Wire Wire Wire Slot Chan case
9 4 27 1 6
10 4 33 0 6
11 4 39 0 6
12 4 45 1 6
Possible cable pull-out
13 4 27 0 6
14 4 33 1 6
15 4 39 1 6
16 4 45 0 6
Possible cable pull-out
17 4 51 1 6
18 4 57 0 6
19 4 63 0 6
Possible cable pull-out
22 4 57 1 6
23 4 63 1 6
24 4 69 0 6
Possible cable pull-out
66 6 9 0 6
67 6 15 0 6
Possible cable pull-out