Here are the signals that have been physically
plugged in the TRGS Bank:
(but the new BOS bank definition hasn't been commited in
recsis yet)
(Scaler 1)
1 CLOCK_UG I 0 9999999 ! Ungated Clock
2 FCUP_UG I 0 9999999 ! FCUP UNGATED
3 NotUsed3 I 0 9999999 ! Currently not used
4 NotUsed4 I 0 9999999 ! Currently not used
5 MOR_ST I 0 9999999 ! MOR.ST
6 MOR_PC I 0 9999999 ! MOR.PC
7 MOR_PS I 0 9999999 ! MOR.PS
8 MOR_TAC I 0 9999999 ! MOR.TAC
9 MOR I 0 9999999 ! Master OR
10 PC I 0 9999999 ! Pair Counter
11 PS I 0 9999999 ! Pair Spectrometer
12 TAC I 0 9999999 ! Total Absorption Counter
13 ST I 0 9999999 ! ST
14 NotUsed14 I 0 9999999 ! Currently not used
15 clock_ug_2 I 0 9999999 ! Currently not used
16 fcup_ug_2 I 0 9999999 ! Currently not used
(scaler 2)
17 CLOCK_G1 I 0 9999999 ! Clock with run gate
18 FCUP_G1 I 0 9999999 ! FCUP with Run Gate
19 NotUsed19 I 0 9999999 ! Currently not used
20 NotUsed20 I 0 9999999 ! Currently not used
21 MOR_ST_rg I 0 9999999 ! MOR.ST with run gate
22 MOR_PC_rg I 0 9999999 ! MOR.PC with run gate
23 MOR_PS_rg I 0 9999999 ! MOR.PS with run gate
24 MOR_TAC_rg I 0 9999999 ! MOR.TAC with run gate
25 MOR_rg I 0 9999999 ! MASTER_OR with run gate
26 PC_rg I 0 9999999 ! PC with run gate
27 PS_rg I 0 9999999 ! PS with run gate
28 TAC_rg I 0 9999999 ! TAC with run gate
29 ST_rg I 0 9999999 ! ST with run gate
30 NotUsed30 I 0 9999999 ! Currently not used
31 clock_g1_2 I 0 9999999 ! Currently not used
32 fcup_g1_2 I 0 9999999 ! Currently not used
(Scaler 3)
33 CLOCK_G2 I 0 9999999 ! CLOCK with Live gate
34 FCUP_G2 I 0 9999999 ! FCUP with Live gate
35 NotUsed35 I 0 9999999 ! Currently not used
36 NotUsed36 I 0 9999999 ! Currently not used
37 NotUsed37 I 0 9999999 ! Currently not used
38 NotUsed38 I 0 9999999 ! Currently not used
39 NotUsed39 I 0 9999999 ! Currently not used
40 NotUsed40 I 0 9999999 ! Currently not used
41 MOR_lg I 0 9999999 ! MASTER_OR with Live gate
42 NotUsed42 I 0 9999999 ! Currently not used
43 NotUsed43 I 0 9999999 ! Currently not used
44 NotUsed44 I 0 9999999 ! Currently not used
45 NotUsed45 I 0 9999999 ! Currently not used
46 NotUsed46 I 0 9999999 ! Currently not used
47 clock_g2_2 I 0 9999999 ! Currently not used
48 fcup_g2_2 I 0 9999999 ! Currently not used
(scaler 4)
49 trig1_ug I 0 9999999 ! Trigger 1 ungated, prescaled
50 trig2_ug I 0 9999999 ! Trigger 2 ungated, prescaled
51 trig3_ug I 0 9999999 ! Trigger 3 ungated, prescaled
52 trig4_ug I 0 9999999 ! Trigger 4 ungated, prescaled
53 trig5_ug I 0 9999999 ! Trigger 5 ungated, prescaled
54 trig6_ug I 0 9999999 ! Trigger 6 ungated, prescaled
55 trig7_ug I 0 9999999 ! Trigger 7 ungated, prescaled
56 trig8_ug I 0 9999999 ! Trigger 8 ungated, prescaled
57 trig9_ug I 0 9999999 ! Trigger 9 ungated, prescaled
58 trig10_ug I 0 9999999 ! Trigger 10 ungated, prescaled
59 trig11_ug I 0 9999999 ! Trigger 11 ungated, prescaled
60 trig12_ug I 0 9999999 ! Trigger 12 ungated, prescaled
61 trig_or_ug I 0 9999999 ! Trigger OR of 1-12 ungated,
prescaled
62 notused62 I 0 9999999 ! Currently not used
63 notused63 I 0 9999999 ! Currently not used
64 notused64 I 0 9999999 ! Currently not used
IN addition to this, channels 62, 63, 64 of the raw T scalers are
fed with the following signals:
62 PC
63 PS
64 TAC
Some signals are also brought upstairs in the couting room]
(for timing check):
Trigger:
PC before the coincidence module
TAC before the coincidence module
ST before the coincidence module
MOR before the coincidence module
WARNING : DANGER : THOSE SIGNAL ARE TAKEN FROM THE ECL/NIM/ECL
TRANSLATOR THAT GOES TO THE TRGS SCALERS, IF THERE ARE NOT USED
AND NOT TERMINATED IN THE COUNTING ROOM, THERE WILL BE
A REFLECTION BACK TO THIS (WEAK) MODULE AND THERE WILL
BE DOUBLE PULSING IN THE SCALER.
SO: WHEN NOT USING THE SIGNAL IN THE COUNTING ROOM, TERMINATE
THEM WITH 50 OHMS !!!!
scalers:
one T as it enters the DSD.T discriminator
PC as it enters the DSD.T discriminator (minus a few ns of ecl ribbon)
PS as it enters the DSD.T discriminator (minus a few ns of ecl ribbon)
TAC as it enters the DSD.T discriminator (minus a few ns of ecl ribbon)
Others:
Busy signal from trigger
analog signal of the TAC sum
let's have a wonderfull commissioning
eric
--