General Setup:
Tagger Magnet ON (Current setting for 4 GeV = ...)
Radiator IN (10**-6)
Target IN (Saclay H target)
Readout: TOF and Tagger crates required. (Note: Including ADCs with beamline devices).
Readout: Other CLAS systems desirable.
0. Tune photon beam with 4 GeV electrons.
1. Look at the four E-counter pmt signals (available in counting house) and do gain
matching "by eye" on the scope.
Vary HV to understand voltage dependence of signal.
Question: Can we bring up a T-counter signal with corresponding E counter to check E-T timing?
2. Check Timing in the data.
Setup Trigger using Steve's configuration file (before PRESTART)
A) Trigger (Trigger Supervisor Input=1) : Level 1 (File = MinDEDX_TOF_ECALlow_Sect123456.trg)
B) Trigger (Trigger Supervisor Input=1) : Tagger (asynch input)
* Level 1 (Trigger file = MinDEDX_TOF_ECALlow_Asynch_Sect123456.trg)
C) Trigger (Trigger Supervisor Input=8, Low intensity, Prescale factor as required) :
Tagger only