> Hello TOF,
>
> I just checked the current contends of the MAP, and I have to admit I am a
> little confused with the increase in items. Mostly, could somebody explain
> the following arrays:
>
> TSIG0
This the measured resolution of each time-of-flight counter (correct me if
I'm wrong, Elton).
> TSIG1
This the second moment of the above.
> T_LR0
This is a left-right time offset parameter for time-matching within a
paddle.
> T_c2c ( My guess: a time offset derived from counter to counter
> calibrations.)
>
That is correct.
> M0 and M0u
M0 is the energy calibration value, being the position in ADC channels at
which normally incident minimum-ionizing particles show up. M0u is the
uncertainty in this number.
> STATUS ( Some error status, I'd like to know what goes in and whether
> pedestals or TDCcal should update it. )
>
I believe this has yet to be decided.
> lambda
This is the attenuation length of the paddle.
> veff
>
This is the effective speed of light in the plastic.
> Thanks a lot,
>
> Maurik
>
>
You're welcome.
Simon.