So our strategy is to produce maximum reconstruction before
connection with other detectors and our output object is showers. The reason
for inner/outer energy separation in output bank is to have more info for
pion rejection etc. Of cource some showers can contains only one part.
New s/r ec_fill_bos will create ECRB bank with number zero. It following to
Kevin's ecfit_hits_showers algorithm so ECRB will contains showers with maximum
probability. It could be changed but main work for algorithm improvement should
be done on previous steps. 45-th variable containce sector number. Coordinate
errors not implemented yet.
I changed ecfit_hits_showers, ecfit_analyse and ec_evnt and removed ec_output
and ecdrv_results; ecrb.ddl changed also.
Serguei