This is about latest fits for momentum corrections and effect of Peter's Patch
Correction to correct specifically small angles. Since we did not have much
time in the meeting to look at these plots together, I created a small Readme
file that explains some details and includes links to relevant directories
with plots. The site is still being developed but it now has enough
information now for finding around your way with some effort.
So, please visit the site:
http://www.jlab.org/Hall-B/secure/eg1/EG2000/nevzat/MOMCORR/Readme.html
And I specifically want to draw your attention to a paragraph that says
following (This came up in the meeting and I tested it):
MoniData_NoPatch: I obtained the old parameters again just to see if I can
obtain a similar set of parameters as the ones that I already have. This is to
test if something changed in the fitting program or if there is and
mulfunction. Our main concern here is the source of the shift in calculated
beam energy after Patch correction applied. Both columns of plots in this case
represents the old (original with no patch correction) parameters. They should
look very similar. The left column is old parameters, the right column is with
newly obtained old parameters. These plots actually concludes that the shift
in the calculation of beam energy is not due to some fitting mulfunction but
it is real effect of Patch correction.