    keyword=End_of_Run_4629
    ****************************
     Run Number: 4629
     End of Run Comment:
    Run_type=cosmics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=just turn on all HV,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=Edna,target_polarization=55.2,target_type=Empty
     
    
    PRESCALE FACTORS:ps1=1000   ps2=1   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 128915       [+]: 48236        [-]: 48244        
    TIME  [0]: 18.088 mins  [+]: 8.901 mins  [-]: 8.900 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         0.12133 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 2.3/2281.5 Hz   T2[0] :90.5/90.5 Hz   T3[0] : 8.7/8.7  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] : 2.3/2281.3 Hz   T2[+] :90.6/90.6 Hz   T3[+] : 8.6/8.6  Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.5/8.5  Hz   T8[+] : 0.0/105000.0 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] : 2.3/2281.3 Hz   T2[-] :90.5/90.5 Hz   T3[-] : 8.8/8.8  Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.6/8.6  Hz   T8[-] : 0.0/105000.0 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2476/2476103  T2[0] :  98265/98265    T3[0] :   9422/9422     T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :   9289/9289     T8[0] :      0/113953962  T9[0] :  32455/32455    
    T1[+] :   1218/1218312  T2[+] :  48395/48395    T3[+] :   4587/4587     T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   4515/4515     T8[+] :      0/56075176  T9[+] :      0/0        
    T1[-] :   1218/1218251  T2[-] :  48319/48319    T3[-] :   4677/4677     T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   4619/4619     T8[-] :      0/56071667  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.1312 uA  BCM x3 : 0.0196 uA  BCM x10: -0.0050uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    233.2 ppm     BCM u3 :    -1254 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    105.2 ppm     BCM d3 :-2.236E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.00017        BCM u3 [0]:4.215E-05      BCM u10[0]:-4.713E-06     
    BCM u1 [+]:8.369E-05      BCM u3 [+]:2.071E-05      BCM u10[+]:-2.316E-06     
    BCM u1 [-]:8.364E-05      BCM u3 [-]:2.076E-05      BCM u10[-]:-2.319E-06     
    
    BCM d1 [0]:0.0001147      BCM d3 [0]:3.598E-07      BCM d10[0]:-6.131E-06     
    BCM d1 [+]:5.645E-05      BCM d3 [+]:1.656E-07      BCM d10[+]:-3.02E-06      
    BCM d1 [-]:5.643E-05      BCM d3 [-]:1.732E-07      BCM d10[-]:-3.018E-06     
    
    
    
    ****************************