     Run Number: 4631
     End of Run Comment:
    Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Carbon foil run with 0.2 uA beam prescale is 100000:1:1,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=Edna,target_polarization=55.2,target_type=BeO Carbon foils
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 54299        [+]: 24032        [-]: 24011        
    TIME  [0]: 3.374 mins  [+]: 1.653 mins  [-]: 1.652 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         0.98371 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 1.6/163302.4 Hz   T2[0] :253.9/253.9 Hz   T3[0] :26.9/26.9 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] : 1.6/163053.1 Hz   T2[+] :254.3/254.3 Hz   T3[+] :27.2/27.2 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.4/8.4  Hz   T8[+] : 0.0/104999.9 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] : 1.6/163698.3 Hz   T2[-] :253.9/253.9 Hz   T3[-] :26.8/26.8 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.7/8.7  Hz   T8[-] : 0.0/105000.1 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    330/33061054  T2[0] :  51409/51409    T3[0] :   5449/5449     T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :   1733/1733     T8[0] :      0/21257565  T9[0] :   6054/6054     
    T1[+] :    161/16169095  T2[+] :  25221/25221    T3[+] :   2693/2693     T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :    836/836      T8[+] :      0/10412270  T9[+] :      0/0        
    T1[-] :    162/16227725  T2[-] :  25165/25165    T3[-] :   2654/2654     T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :    863/863      T8[-] :      0/10408859  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.4093 uA  BCM x3 : 0.3018 uA  BCM x10: 0.2784 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1180 ppm     BCM u3 :    -1711 ppm     BCM u10:    -2127 ppm     
    BCM d1 :    -1684 ppm     BCM d3 :    -1737 ppm     BCM d10:    -2054 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:8.768E-05      BCM u3 [0]:6.49E-05       BCM u10[0]:5.642E-05      
    BCM u1 [+]:4.293E-05      BCM u3 [+]:3.175E-05      BCM u10[+]:2.759E-05      
    BCM u1 [-]:4.302E-05      BCM u3 [-]:3.185E-05      BCM u10[-]:2.77E-05       
    
    BCM d1 [0]:7.805E-05      BCM d3 [0]:5.728E-05      BCM d10[0]:5.63E-05       
    BCM d1 [+]:3.819E-05      BCM d3 [+]:2.803E-05      BCM d10[+]:2.754E-05      
    BCM d1 [-]:3.831E-05      BCM d3 [-]:2.812E-05      BCM d10[-]:2.765E-05      
    
    
    
    ****************************