Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:07:37 on May 11, 2006

    Entry number 173681

    keyword=End_of_Run_4634
    ****************************
     Run Number: 4634
     End of Run Comment:
    Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Carbon foil run with 0.5 uA beam prescale is 100000:1:1 raster size 1.5x1.5 on MCC side,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=BeO Carbon foils
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 198708       [+]: 91846        [-]: 91931        
    TIME  [0]: 7.650 mins  [+]: 3.760 mins  [-]: 3.760 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         0.61598 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 2.6/260388.3 Hz   T2[0] :432.2/432.2 Hz   T3[0] :43.9/43.9 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] : 2.6/259819.4 Hz   T2[+] :431.9/431.9 Hz   T3[+] :44.4/44.4 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.8/8.8  Hz   T8[+] : 0.0/105000.1 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] : 2.6/260928.3 Hz   T2[-] :432.7/432.7 Hz   T3[-] :43.4/43.4 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.3/8.3  Hz   T8[-] : 0.0/105000.0 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1195/119524548  T2[0] : 198407/198407   T3[0] :  20141/20141    T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :   3928/3928     T8[0] :      0/48197543  T9[0] :  13727/13727    
    T1[+] :    586/58618081  T2[+] :  97433/97433    T3[+] :  10015/10015    T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   1985/1985     T8[+] :      0/23689163  T9[+] :      0/0        
    T1[-] :    588/58859756  T2[-] :  97611/97611    T3[-] :   9799/9799     T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   1878/1878     T8[-] :      0/23685731  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.5909 uA  BCM x3 : 0.4838 uA  BCM x10: 0.4605 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1589 ppm     BCM u3 :    -1916 ppm     BCM u10:    -2120 ppm     
    BCM d1 :    -1701 ppm     BCM d3 :    -2036 ppm     BCM d10:    -2135 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0002814      BCM u3 [0]:0.0002298      BCM u10[0]:0.0002108      
    BCM u1 [+]:0.0001381      BCM u3 [+]:0.0001128      BCM u10[+]:0.0001034      
    BCM u1 [-]:0.0001385      BCM u3 [-]:0.0001132      BCM u10[-]:0.0001038      
    
    BCM d1 [0]:0.0002611      BCM d3 [0]:0.0002143      BCM d10[0]:0.000212       
    BCM d1 [+]:0.0001281      BCM d3 [+]:0.0001051      BCM d10[+]:0.000104       
    BCM d1 [-]:0.0001285      BCM d3 [-]:0.0001055      BCM d10[-]:0.0001044      
    
    
    
    ****************************