Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:10:04 on May 11, 2006

    Entry number 173682

    keyword=Start_Run_4635,Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Carbon foil run with 1.2 uA beam prescale is 100000:1:1 raster size 1.5x1.5 on MCC side,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 4635 at Thu May 11 20:09:55 EDT 2006
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = N-arm singles
    ; T2 = e-arm singles
    ; T3 = e-N coincidence
    ; T4 = empty
    ; T7 = ~10 Hz pulser
    ; WARNING T8 has ps8=210 hardcode in Trig.Super. at the moment.
    ;         Set prescale for T8 to 0 for correct datamon deadtime
    ; DO NOT touch the prescale for PS 8 (it should be 0)
    ;
    ps1=100000,ps2=1,ps3=1,ps4=9999,ps5=9999,ps6=9999,ps7=1,ps8=0
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.553
    -----
    Average current of the two cavities : 1.17165
    Current on Unser monitor : -4.87877
    Current on Upstream bcm : 1.19589
    Current on Downstream bcm : 1.1474
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 2079.9
    Tiefenbach Hall C energy : 686.406
    Delta(E)/E width (MV_AI_DXWID) : 1.09219
    HALLA:p : 2079.9
    HALLA:dpp : 0.000111052
    MBSY1c Hall A Beam energy : 2081.98
    MBSY3c Hall C Beam energy : 687.065
    MBSY1c magnet current (amp) : 86.6236
    MBSY1c Bdl : 519561
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    -----
    IPM1C12.XPOS : -0.331322
    IPM1C12.YPOS : 0.250207
    IPM1H04A.XPOS : -1.4146
    IPM1H04A.YPOS : -1.42005
    IPM1H04B.XPOS : -1.3401
    IPM1H04B.YPOS : -1.09114
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 57.2136
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 38.099
    Laser attenuation Hall A : 116
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 8000
    Beam Half-wave plate (off=out) : OUT
    -----
    Neutron arm threshold: -180
    BigBite Preshower threshold: -25
    BigBite TotalShower threshold: -110
    -----
    BigBite DC Voltage Ch1 Cathode Front : -1658
    BigBite DC Voltage Ch1 Cathode Back : -1661
    BigBite DC Voltage Ch1 Field : -1635
    BigBite DC Voltage Ch2 Cathode : -1870
    BigBite DC Voltage Ch2 Cathode : -1864
    BigBite DC Voltage Ch2 Field : -1800
    BigBite DC Voltage Ch3 Cathode Top Front : -1897
    BigBite DC Voltage Ch3 Cathode Bot. Front : -1899
    BigBite DC Voltage Ch3 Cathode Top Back : -1905
    BigBite DC Voltage Ch3 Cathode Bot. Back : -1906
    BigBite DC Voltage Ch3 Field : -1801
    -----
    BigBite DC Current Ch1 Cathode Front : -57
    BigBite DC Current Ch1 Cathode Back : -62
    BigBite DC Current Ch1 Field : -11
    BigBite DC Current Ch2 Cathode : -85
    BigBite DC Current Ch2 Cathode : -85
    BigBite DC Current Ch2 Field : -15
    BigBite DC Current Ch3 Cathode Top Front : -63
    BigBite DC Current Ch3 Cathode Bot. Front : -60
    BigBite DC Current Ch3 Cathode Top Back : -65
    BigBite DC Current Ch3 Cathode Bot. Back : -62
    BigBite DC Current Ch3 Field : -12
    -----
    HacAi_hpchan0: Temp at Target Cell: 168.896
    HacAi_hpchan1: Temp at Target Cell: 0
    HacAi_hpchan2: Temp at Target Cell: 0
    HacAi_hpchan3: Temp at Target Cell: 135.42
    HacAi_hpchan4: Temp at Target Cell: 0
    HacAi_hpchan5: Temp at Target Cell: 0
    HacAi_hpchan6: Temp at Target Cell: 0
    HacAi_hpchan7: Temp at Target Cell: 26.5527
    HacAi_hpchan8: Temp at Target Cell: 26.8359
    HacAi_hpchan9: Temp at Target Cell: 26.7676
    HacAi_hpchan60: Temp at Target Cell: -22.0197
    HacAi_hpchan61: Temp at Target Cell: 122.216
    HacAi_hpchan62: Temp at Target Cell: 404.15
    Target position: 31.582
    Oven Air Flow: 0
    Over Heater Temperature: 29
    -----
    HaGenTargBrake : On
    HaGenTargBrake : On
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : ?+9999.
    HacOMEGA_SP1 : 20
    HacOMEGA_PROP1 : 3200
    HacOMEGA_RST1 : 100
    HacOMEGA_RATE : 1
    pol3heSmallCoilCurrent : 0
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 15
    CLASER_TEMP : 8
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR CLASER2_TEMP : 35 11.7
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 35000
    CLASERAB_GETCUR : 35000
    CLASERAB_GETTEMP0 : 16.7
    CLASERAB_GETTEMP : 11.1
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 35
    CLASER3_TEMP : 16.1
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    CLASERAB2_STATE_M: Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR : 0
    CLASERAB2_GETTEMP : 0
    CLASERAB2_GETTEMP1 : 0
    ----