NEXT
User name a-onl
Log entry time 20:14:54 on May 11, 2006
Entry number 173685
keyword=End_of_Run_4635
****************************
Run Number: 4635
End of Run Comment:
Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Carbon foil run with 1.2 uA beam prescale is 100000:1:1 raster size 1.5x1.5 on MCC side,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=BeO Carbon foils
PRESCALE FACTORS:ps1=100000 ps2=1 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 229190 [+]: 108802 [-]: 109637
TIME [0]: 5.116 mins [+]: 2.509 mins [-]: 2.509 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 1.03394 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] : 4.7/471302.5 Hz T2[0] :848.5/848.5 Hz T3[0] :121.6/121.6 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] : 4.7/469710.5 Hz T2[+] :845.7/845.7 Hz T3[+] :120.4/120.4 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.2/8.2 Hz T8[+] : 0.0/105000.0 Hz T9[+] : 0.0/0.0 Hz
T1[-] : 4.7/471562.8 Hz T2[-] :849.4/849.4 Hz T3[-] :122.7/122.7 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.9/8.9 Hz T8[-] : 0.0/104999.8 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 1446/144663713 T2[0] : 260436/260436 T3[0] : 37328/37328 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 2628/2628 T8[0] : 0/32229170 T9[0] : 9179/9179
T1[+] : 707/70705650 T2[+] : 127301/127301 T3[+] : 18121/18121 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 1235/1235 T8[+] : 0/15805680 T9[+] : 0/0
T1[-] : 709/70999805 T2[-] : 127884/127884 T3[-] : 18468/18468 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 1344/1344 T8[-] : 0/15809068 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 1.0071 uA BCM x3 : 0.8990 uA BCM x10: 0.8756 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1492 ppm BCM u3 : -1589 ppm BCM u10: -1743 ppm
BCM d1 : -1759 ppm BCM d3 : -1659 ppm BCM d10: -1733 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0003146 BCM u3 [0]:0.0002796 BCM u10[0]:0.0002671
BCM u1 [+]:0.0001539 BCM u3 [+]:0.0001367 BCM u10[+]:0.0001306
BCM u1 [-]:0.0001544 BCM u3 [-]:0.0001372 BCM u10[-]:0.0001311
BCM d1 [0]:0.0003037 BCM d3 [0]:0.0002723 BCM d10[0]:0.0002704
BCM d1 [+]:0.0001485 BCM d3 [+]:0.0001331 BCM d10[+]:0.0001322
BCM d1 [-]:0.000149 BCM d3 [-]:0.0001336 BCM d10[-]:0.0001327
****************************