NEXT
User name a-onl
Log entry time 20:59:40 on May 11, 2006
Entry number 173689
keyword=Start_Run_4637,Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC1.5*1.5 raster - ND cosmics,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
Beginning-of-run EPICS data for Run Number 4637 at Thu May 11 20:59:33 EDT 2006
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = N-arm singles
; T2 = e-arm singles
; T3 = e-N coincidence
; T4 = empty
; T7 = ~10 Hz pulser
; WARNING T8 has ps8=210 hardcode in Trig.Super. at the moment.
; Set prescale for T8 to 0 for correct datamon deadtime
; DO NOT touch the prescale for PS 8 (it should be 0)
;
ps1=1,ps2=10,ps3=1,ps4=9999,ps5=9999,ps6=9999,ps7=1,ps8=0
-----
BigBite magnet current setpoint : 710
BigBite magnet current readback : 706.553
-----
Average current of the two cavities : 0.0333916
Current on Unser monitor : -5.71968
Current on Upstream bcm : 0.0499017
Current on Downstream bcm : 0.0168814
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 2079.67
Tiefenbach Hall C energy : 686.406
Delta(E)/E width (MV_AI_DXWID) : 1.18752
HALLA:p : 2079.67
HALLA:dpp : 0
MBSY1c Hall A Beam energy : 2081.98
MBSY3c Hall C Beam energy : 687.065
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 519561
Arc1 dp/p : 0
Arc2 dp/p : 0
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 57.2136
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 38.099
Laser attenuation Hall A : 191
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 8000
Beam Half-wave plate (off=out) : OUT
-----
Neutron arm threshold: -180
BigBite Preshower threshold: -25
BigBite TotalShower threshold: -110
-----
BigBite DC Voltage Ch1 Cathode Front : -1653
BigBite DC Voltage Ch1 Cathode Back : -1656
BigBite DC Voltage Ch1 Field : -1636
BigBite DC Voltage Ch2 Cathode : -1838
BigBite DC Voltage Ch2 Cathode : -1838
BigBite DC Voltage Ch2 Field : -1789
BigBite DC Voltage Ch3 Cathode Top Front : -1842
BigBite DC Voltage Ch3 Cathode Bot. Front : -1847
BigBite DC Voltage Ch3 Cathode Top Back : -1843
BigBite DC Voltage Ch3 Cathode Bot. Back : -1852
BigBite DC Voltage Ch3 Field : -1794
-----
BigBite DC Current Ch1 Cathode Front : -0
BigBite DC Current Ch1 Cathode Back : -0
BigBite DC Current Ch1 Field : -0
BigBite DC Current Ch2 Cathode : -0
BigBite DC Current Ch2 Cathode : -0
BigBite DC Current Ch2 Field : -0
BigBite DC Current Ch3 Cathode Top Front : -0
BigBite DC Current Ch3 Cathode Bot. Front : -0
BigBite DC Current Ch3 Cathode Top Back : -0
BigBite DC Current Ch3 Cathode Bot. Back : -0
BigBite DC Current Ch3 Field : -0
-----
HacAi_hpchan0: Temp at Target Cell: 168.945
HacAi_hpchan1: Temp at Target Cell: 0
HacAi_hpchan2: Temp at Target Cell: 0
HacAi_hpchan3: Temp at Target Cell: 135.039
HacAi_hpchan4: Temp at Target Cell: 0
HacAi_hpchan5: Temp at Target Cell: 0
HacAi_hpchan6: Temp at Target Cell: 0
HacAi_hpchan7: Temp at Target Cell: 26.5234
HacAi_hpchan8: Temp at Target Cell: 27.0508
HacAi_hpchan9: Temp at Target Cell: 26.7969
HacAi_hpchan60: Temp at Target Cell: -34.5914
HacAi_hpchan61: Temp at Target Cell: 129.039
HacAi_hpchan62: Temp at Target Cell: 404.407
Target position: 26.686
Oven Air Flow: 0
Over Heater Temperature: 29.1
-----
HaGenTargBrake : On
HaGenTargBrake : On
HacOMEGA_AL1 : 0
HacOMEGA_READ : ?+9999.
HacOMEGA_SP1 : 20
HacOMEGA_PROP1 : 3200
HacOMEGA_RST1 : 100
HacOMEGA_RATE : 1
pol3heSmallCoilCurrent : 0
CLASER_STATE_MB : Disabled
CLASER_RDCUR : 15
CLASER_TEMP : 8
CLASER2_STATE_MB : Disabled
CLASER2_RDCUR CLASER2_TEMP : 35 11.7
CLASERAB_STATE_MB : Disabled
CLASERAB_GETCUR0 : 35000
CLASERAB_GETCUR : 35000
CLASERAB_GETTEMP0 : 16.7
CLASERAB_GETTEMP : 11.1
CLASER3_STATE_MB : Disabled
CLASER3_RDCUR : 35
CLASER3_TEMP : 16.1
CLASER4_STATE_MB : Disabled
CLASER4_RDCUR : 0
CLASER4_TEMP : 0
CLASERAB2_STATE_M: Disabled
CLASERAB2_GETCUR0 : 0
CLASERAB2_GETCUR : 0
CLASERAB2_GETTEMP : 0
CLASERAB2_GETTEMP1 : 0
----