NEXT
User name a-onl
Log entry time 21:29:40 on May 11, 2006
Entry number 173691
keyword=End_of_Run_4637
****************************
Run Number: 4637
End of Run Comment:
Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC1.5*1.5 raster - ND cosmics,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
PRESCALE FACTORS:ps1=1 ps2=10 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 1407006 [+]: 670122 [-]: 671332
TIME [0]: 30.900 mins [+]: 15.212 mins [-]: 15.212 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -0.62400 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] :830.6/830.6 Hz T2[0] : 1.0/10.2 Hz T3[0] : 8.6/8.6 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] :829.7/829.7 Hz T2[+] : 1.0/10.3 Hz T3[+] : 8.6/8.6 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.6/8.6 Hz T8[+] : 0.0/105000.0 Hz T9[+] : 0.0/0.0 Hz
T1[-] :831.6/831.6 Hz T2[-] : 1.0/10.2 Hz T3[-] : 8.5/8.5 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.5/8.5 Hz T8[-] : 0.0/105000.0 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :1540028/1540028 T2[0] : 1894/18948 T3[0] : 15890/15890 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 15870/15870 T8[0] : 0/194671788 T9[0] : 55444/55444
T1[+] : 757302/757302 T2[+] : 939/9390 T3[+] : 7880/7880 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 7870/7870 T8[+] : 0/95835298 T9[+] : 0/0
T1[-] : 758998/758998 T2[-] : 927/9274 T3[-] : 7769/7769 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 7759/7759 T8[-] : 0/95835259 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 0.1311 uA BCM x3 : 0.0188 uA BCM x10: -0.0074uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 143.7 ppm BCM u3 : -468.1 ppm BCM u10: 1E+39 ppm
BCM d1 : -173.4 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0002906 BCM u3 [0]:7.171E-05 BCM u10[0]:-1.058E-05
BCM u1 [+]:0.0001431 BCM u3 [+]:3.53E-05 BCM u10[+]:-5.209E-06
BCM u1 [-]:0.000143 BCM u3 [-]:3.533E-05 BCM u10[-]:-5.204E-06
BCM d1 [0]:0.0001956 BCM d3 [0]:-1.903E-06 BCM d10[0]:-1.68E-05
BCM d1 [+]:9.628E-05 BCM d3 [+]:-9.334E-07 BCM d10[+]:-8.268E-06
BCM d1 [-]:9.632E-05 BCM d3 [-]:-9.503E-07 BCM d10[-]:-8.268E-06
****************************