Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:26:24 on May 11, 2006

    Entry number 173699

    keyword=End_of_Run_4639
    ****************************
     Run Number: 4639
     End of Run Comment:
    Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC1.5*1.5 raster - ND cosmics,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     good run
    
    PRESCALE FACTORS:ps1=100000   ps2=10   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 1003918      [+]: 457945       [-]: 458525       
    TIME  [0]: 45.160 mins  [+]: 22.237 mins  [-]: 22.237 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.54679 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :-0.8/-75588.1 Hz   T2[0] :98.7/986.9 Hz   T3[0] :284.1/284.1 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] :15.1/1506863.0 Hz   T2[+] :98.7/987.0 Hz   T3[+] :283.8/283.8 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.5/8.5  Hz   T8[+] : 0.0/105000.1 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] :15.1/1511510.8 Hz   T2[-] :98.7/986.9 Hz   T3[-] :284.5/284.5 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.6/8.6  Hz   T8[-] : 0.0/104999.9 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  -2049/-204811894  T2[0] : 267418/2674182  T3[0] : 769841/769841   T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :  23194/23194    T8[0] :      0/284505799  T9[0] :  81029/81029    
    T1[+] :  20104/2010455360  T2[+] : 131687/1316873  T3[+] : 378692/378692   T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :  11319/11319    T8[+] :      0/140091017  T9[+] :      0/0        
    T1[-] :  20167/2016705678  T2[-] : 131677/1316776  T3[-] : 379560/379560   T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :  11531/11531    T8[-] :      0/140094228  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 3.9969 uA  BCM x3 : 3.8902 uA  BCM x10: 3.8694 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1481 ppm     BCM u3 :    -1508 ppm     BCM u10:    -1532 ppm     
    BCM d1 :    -1516 ppm     BCM d3 :    -1503 ppm     BCM d10:    -1526 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0108         BCM u3 [0]:0.0105         BCM u10[0]:0.0104         
    BCM u1 [+]:0.005312       BCM u3 [+]:0.005161       BCM u10[+]:0.005114       
    BCM u1 [-]:0.005328       BCM u3 [-]:0.005177       BCM u10[-]:0.005129       
    
    BCM d1 [0]:0.01086        BCM d3 [0]:0.01058        BCM d10[0]:0.01057        
    BCM d1 [+]:0.005338       BCM d3 [+]:0.005204       BCM d10[+]:0.005196       
    BCM d1 [-]:0.005354       BCM d3 [-]:0.00522        BCM d10[-]:0.005212       
    
    
    
    ****************************