    keyword=End_of_Run_4640
    ****************************
     Run Number: 4640
     End of Run Comment:
    Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC1.5*1.5 raster ,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     
    
    PRESCALE FACTORS:ps1=100000   ps2=10   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 528140       [+]: 240284       [-]: 241404       
    TIME  [0]: 23.234 mins  [+]: 11.408 mins  [-]: 11.409 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         3.13794 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15.1/1510719.1 Hz   T2[0] :101.9/1018.8 Hz   T3[0] :292.1/292.1 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] :15.1/1507773.1 Hz   T2[+] :101.8/1017.7 Hz   T3[+] :291.4/291.4 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.6/8.6  Hz   T8[+] : 0.0/105000.0 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] :15.1/1512624.8 Hz   T2[-] :102.0/1019.7 Hz   T3[-] :292.5/292.5 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.5/8.5  Hz   T8[-] : 0.0/105000.0 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  21060/2106013481  T2[0] : 142019/1420194  T3[0] : 407213/407213   T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :  11932/11932    T8[0] :      0/146374938  T9[0] :  41688/41688    
    T1[+] :  10320/1032049639  T2[+] :  69658/696586   T3[+] : 199435/199435   T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   5874/5874     T8[+] :      0/71871043  T9[+] :      0/0        
    T1[-] :  10354/1035420329  T2[-] :  69803/698031   T3[-] : 200217/200217   T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   5847/5847     T8[-] :      0/71874469  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 4.0176 uA  BCM x3 : 3.9111 uA  BCM x10: 3.8904 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1502 ppm     BCM u3 :    -1528 ppm     BCM u10:    -1553 ppm     
    BCM d1 :    -1548 ppm     BCM d3 :    -1524 ppm     BCM d10:    -1548 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005587       BCM u3 [0]:0.00543        BCM u10[0]:0.005381       
    BCM u1 [+]:0.002739       BCM u3 [+]:0.002662       BCM u10[+]:0.002637       
    BCM u1 [-]:0.002747       BCM u3 [-]:0.00267        BCM u10[-]:0.002646       
    
    BCM d1 [0]:0.005614       BCM d3 [0]:0.005475       BCM d10[0]:0.005466       
    BCM d1 [+]:0.002752       BCM d3 [+]:0.002683       BCM d10[+]:0.002679       
    BCM d1 [-]:0.002761       BCM d3 [-]:0.002692       BCM d10[-]:0.002688       
    
    
    
    ****************************