NEXT
User name a-onl
Log entry time 23:40:39 on May 11, 2006
Entry number 173709
keyword=End_of_Run_4642
****************************
Run Number: 4642
End of Run Comment:
Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
PRESCALE FACTORS:ps1=100000 ps2=10 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 1087655 [+]: 498277 [-]: 499288
TIME [0]: 46.175 mins [+]: 22.737 mins [-]: 22.737 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.57826 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] :-0.0/-1934.9 Hz T2[0] :105.6/1056.4 Hz T3[0] :303.8/303.8 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] :15.5/1545609.4 Hz T2[+] :105.6/1056.0 Hz T3[+] :303.5/303.5 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.6/8.6 Hz T8[+] : 0.0/105000.0 Hz T9[+] : 0.0/0.0 Hz
T1[-] :15.5/1550355.0 Hz T2[-] :105.7/1056.7 Hz T3[-] :304.1/304.1 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.5/8.5 Hz T8[-] : 0.0/104999.9 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : -54/-5360532 T2[0] : 292685/2926856 T3[0] : 841789/841789 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 23715/23715 T8[0] : 0/290902411 T9[0] : 82850/82850
T1[+] : 21085/2108511436 T2[+] : 144057/1440576 T3[+] : 414036/414036 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 11710/11710 T8[+] : 0/143240348 T9[+] : 0/0
T1[-] : 21150/2115038325 T2[-] : 144160/1441600 T3[-] : 414883/414883 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 11640/11640 T8[-] : 0/143243884 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 4.0872 uA BCM x3 : 3.9808 uA BCM x10: 3.9601 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1470 ppm BCM u3 : -1483 ppm BCM u10: -1509 ppm
BCM d1 : -1506 ppm BCM d3 : -1482 ppm BCM d10: -1507 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.01129 BCM u3 [0]:0.01098 BCM u10[0]:0.01088
BCM u1 [+]:0.005553 BCM u3 [+]:0.0054 BCM u10[+]:0.005351
BCM u1 [-]:0.00557 BCM u3 [-]:0.005416 BCM u10[-]:0.005368
BCM d1 [0]:0.01135 BCM d3 [0]:0.01108 BCM d10[0]:0.01106
BCM d1 [+]:0.005581 BCM d3 [+]:0.005445 BCM d10[+]:0.005437
BCM d1 [-]:0.005598 BCM d3 [-]:0.005461 BCM d10[-]:0.005453
****************************