Run Number: 4643
End of Run Comment:
Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
Ended with HV trip on N-arm
PRESCALE FACTORS:ps1=100000 ps2=10 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 113617 [+]: 51308 [-]: 51574
TIME [0]: 4.933 mins [+]: 2.393 mins [-]: 2.392 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 4.25330 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] :15.1/1507037.6 Hz T2[0] :107.2/1071.8 Hz T3[0] :299.5/299.5 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] :15.0/1503303.7 Hz T2[+] :107.2/1072.3 Hz T3[+] :298.3/298.3 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.5/8.5 Hz T8[+] : 0.0/105000.1 Hz T9[+] : 0.0/0.0 Hz
T1[-] :15.1/1507840.1 Hz T2[-] :107.1/1071.1 Hz T3[-] :300.2/300.2 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.6/8.6 Hz T8[-] : 0.0/104999.9 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 4460/446030105 T2[0] : 31722/317223 T3[0] : 88653/88653 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 2534/2534 T8[0] : 0/31076305 T9[0] : 8851/8851
T1[+] : 2158/215836914 T2[+] : 15395/153957 T3[+] : 42827/42827 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 1219/1219 T8[+] : 0/15075391 T9[+] : 0/0
T1[-] : 2164/216439244 T2[-] : 15375/153751 T3[-] : 43087/43087 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 1236/1236 T8[-] : 0/15071960 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 4.1275 uA BCM x3 : 4.0211 uA BCM x10: 4.0006 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1434 ppm BCM u3 : -1462 ppm BCM u10: -1486 ppm
BCM d1 : -1468 ppm BCM d3 : -1465 ppm BCM d10: -1486 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001218 BCM u3 [0]:0.001185 BCM u10[0]:0.001175
BCM u1 [+]:0.00059 BCM u3 [+]:0.0005738 BCM u10[+]:0.0005688
BCM u1 [-]:0.0005916 BCM u3 [-]:0.0005754 BCM u10[-]:0.0005704
BCM d1 [0]:0.001225 BCM d3 [0]:0.001195 BCM d10[0]:0.001194
BCM d1 [+]:0.0005932 BCM d3 [+]:0.0005789 BCM d10[+]:0.000578
BCM d1 [-]:0.0005948 BCM d3 [-]:0.0005805 BCM d10[-]:0.0005796
****************************