Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 23:48:04 on May 11, 2006

    Entry number 173712

    keyword=End_of_Run_4643
    ****************************
     Run Number: 4643
     End of Run Comment:
    Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     Ended with HV trip on N-arm
    
    PRESCALE FACTORS:ps1=100000   ps2=10   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 113617       [+]: 51308        [-]: 51574        
    TIME  [0]: 4.933 mins  [+]: 2.393 mins  [-]: 2.392 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         4.25330 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15.1/1507037.6 Hz   T2[0] :107.2/1071.8 Hz   T3[0] :299.5/299.5 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] :15.0/1503303.7 Hz   T2[+] :107.2/1072.3 Hz   T3[+] :298.3/298.3 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.5/8.5  Hz   T8[+] : 0.0/105000.1 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] :15.1/1507840.1 Hz   T2[-] :107.1/1071.1 Hz   T3[-] :300.2/300.2 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.6/8.6  Hz   T8[-] : 0.0/104999.9 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   4460/446030105  T2[0] :  31722/317223   T3[0] :  88653/88653    T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :   2534/2534     T8[0] :      0/31076305  T9[0] :   8851/8851     
    T1[+] :   2158/215836914  T2[+] :  15395/153957   T3[+] :  42827/42827    T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   1219/1219     T8[+] :      0/15075391  T9[+] :      0/0        
    T1[-] :   2164/216439244  T2[-] :  15375/153751   T3[-] :  43087/43087    T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   1236/1236     T8[-] :      0/15071960  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 4.1275 uA  BCM x3 : 4.0211 uA  BCM x10: 4.0006 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1434 ppm     BCM u3 :    -1462 ppm     BCM u10:    -1486 ppm     
    BCM d1 :    -1468 ppm     BCM d3 :    -1465 ppm     BCM d10:    -1486 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001218       BCM u3 [0]:0.001185       BCM u10[0]:0.001175       
    BCM u1 [+]:0.00059        BCM u3 [+]:0.0005738      BCM u10[+]:0.0005688      
    BCM u1 [-]:0.0005916      BCM u3 [-]:0.0005754      BCM u10[-]:0.0005704      
    
    BCM d1 [0]:0.001225       BCM d3 [0]:0.001195       BCM d10[0]:0.001194       
    BCM d1 [+]:0.0005932      BCM d3 [+]:0.0005789      BCM d10[+]:0.000578       
    BCM d1 [-]:0.0005948      BCM d3 [-]:0.0005805      BCM d10[-]:0.0005796      
    
    
    
    ****************************