    keyword=End_of_Run_4644
    ****************************
     Run Number: 4644
     End of Run Comment:
    Run_type=other,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     
    
    
    PRESCALE FACTORS:ps1=100000   ps2=10   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 368176       [+]: 166639       [-]: 167957       
    TIME  [0]: 16.024 mins  [+]: 7.828 mins  [-]: 7.828 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         7.06347 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15.1/1509386.8 Hz   T2[0] :103.2/1031.7 Hz   T3[0] :296.8/296.8 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] :15.1/1506559.8 Hz   T2[+] :102.9/1029.5 Hz   T3[+] :294.7/294.7 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.4/8.4  Hz   T8[+] : 0.0/105000.0 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] :15.1/1511143.5 Hz   T2[-] :103.3/1032.7 Hz   T3[-] :298.7/298.7 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.7/8.7  Hz   T8[-] : 0.0/104999.9 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  14511/1451193754  T2[0] :  99188/991887   T3[0] : 285371/285371   T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :   8230/8230     T8[0] :      0/100951817  T9[0] :  28752/28752    
    T1[+] :   7075/707595143  T2[+] :  48352/483524   T3[+] : 138417/138417   T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   3962/3962     T8[+] :      0/49316000  T9[+] :      0/0        
    T1[-] :   7097/709748858  T2[-] :  48503/485033   T3[-] : 140284/140284   T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   4079/4079     T8[-] :      0/49316005  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 3.9710 uA  BCM x3 : 3.8646 uA  BCM x10: 3.8439 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1492 ppm     BCM u3 :    -1512 ppm     BCM u10:    -1540 ppm     
    BCM d1 :    -1539 ppm     BCM d3 :    -1518 ppm     BCM d10:    -1537 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.003809       BCM u3 [0]:0.0037         BCM u10[0]:0.003666       
    BCM u1 [+]:0.001857       BCM u3 [+]:0.001805       BCM u10[+]:0.001788       
    BCM u1 [-]:0.001863       BCM u3 [-]:0.00181        BCM u10[-]:0.001793       
    
    BCM d1 [0]:0.003827       BCM d3 [0]:0.003731       BCM d10[0]:0.003725       
    BCM d1 [+]:0.001866       BCM d3 [+]:0.00182        BCM d10[+]:0.001817       
    BCM d1 [-]:0.001872       BCM d3 [-]:0.001825       BCM d10[-]:0.001822       
    
    
    
    ****************************