    Log entry time 01:17:02 on May 12, 2006

    Entry number 173720

    keyword=End_of_Run_4645
    ****************************
     Run Number: 4645
     End of Run Comment:
    Run_type=cosmics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     
    
    PRESCALE FACTORS:ps1=100000   ps2=10   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 11357        [+]: 1281         [-]: 1241         
    TIME  [0]: 5.009 mins  [+]: 2.458 mins  [-]: 2.458 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         0.86673 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/860.1 Hz   T2[0] : 1.0/10.2 Hz   T3[0] : 8.6/8.6  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] : 0.0/863.2 Hz   T2[+] : 1.0/10.3 Hz   T3[+] : 8.7/8.7  Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.6/8.6  Hz   T8[+] : 0.0/105000.1 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] : 0.0/857.8 Hz   T2[-] : 1.0/10.1 Hz   T3[-] : 8.5/8.5  Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.5/8.5  Hz   T8[-] : 0.0/105000.0 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      2/258497   T2[0] :    306/3061     T3[0] :   2576/2576     T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :   2572/2572     T8[0] :      0/31557165  T9[0] :   8988/8988     
    T1[+] :      1/127316   T2[+] :    151/1519     T3[+] :   1276/1276     T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   1274/1274     T8[+] :      0/15487041  T9[+] :      0/0        
    T1[-] :      1/126490   T2[-] :    148/1486     T3[-] :   1252/1252     T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   1250/1250     T8[-] :      0/15483598  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.1323 uA  BCM x3 : 0.0192 uA  BCM x10: -0.0071uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -13.87 ppm     BCM u3 :    407.7 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -160.8 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:4.743E-05      BCM u3 [0]:1.183E-05      BCM u10[0]:-1.674E-06     
    BCM u1 [+]:2.328E-05      BCM u3 [+]:5.811E-06      BCM u10[+]:-8.231E-07     
    BCM u1 [-]:2.328E-05      BCM u3 [-]:5.805E-06      BCM u10[-]:-8.191E-07     
    
    BCM d1 [0]:3.212E-05      BCM d3 [0]:-2.803E-07     BCM d10[0]:-2.612E-06     
    BCM d1 [+]:1.576E-05      BCM d3 [+]:-1.391E-07     BCM d10[+]:-1.279E-06     
    BCM d1 [-]:1.576E-05      BCM d3 [-]:-1.366E-07     BCM d10[-]:-1.284E-06     
    
    
    
    ****************************