    User name a-onl

    Log entry time 01:29:07 on May 12, 2006

    Entry number 173724

    keyword=End_of_Run_4647
    ****************************
     Run Number: 4647
     End of Run Comment:
    Run_type=cosmics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     
    
    PRESCALE FACTORS:ps1=100000   ps2=10   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 1400         [+]: 161          [-]: 150          
    TIME  [0]: 0.694 mins  [+]: 0.333 mins  [-]: 0.333 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         1.02983 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/860.3 Hz   T2[0] : 1.0/10.1 Hz   T3[0] : 8.5/8.5  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.5/8.5  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] : 0.0/861.9 Hz   T2[+] : 1.1/10.7 Hz   T3[+] : 9.0/9.0  Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 9.0/9.0  Hz   T8[+] : 0.0/104999.8 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] : 0.0/856.4 Hz   T2[-] : 1.0/9.5  Hz   T3[-] : 8.1/8.1  Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.1/8.1  Hz   T8[-] : 0.0/105000.4 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/35818    T2[0] :     42/421      T3[0] :    355/355      T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :    355/355      T8[0] :      0/4371392  T9[0] :   1244/1244     
    T1[+] :      0/17236    T2[+] :     21/213      T3[+] :    180/180      T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :    180/180      T8[+] :      0/2099811  T9[+] :      0/0        
    T1[-] :      0/17098    T2[-] :     19/190      T3[-] :    162/162      T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :    162/162      T8[-] :      0/2096314  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.1324 uA  BCM x3 : 0.0193 uA  BCM x10: -0.0072uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    936.9 ppm     BCM u3 :    -1220 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    523.2 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:6.573E-06      BCM u3 [0]:1.644E-06      BCM u10[0]:-2.322E-07     
    BCM u1 [+]:3.163E-06      BCM u3 [+]:7.882E-07      BCM u10[+]:-1.106E-07     
    BCM u1 [-]:3.151E-06      BCM u3 [-]:7.888E-07      BCM u10[-]:-1.119E-07     
    
    BCM d1 [0]:4.452E-06      BCM d3 [0]:-3.499E-08     BCM d10[0]:-3.689E-07     
    BCM d1 [+]:2.136E-06      BCM d3 [+]:-1.524E-08     BCM d10[+]:-1.78E-07      
    BCM d1 [-]:2.13E-06       BCM d3 [-]:-1.722E-08     BCM d10[-]:-1.761E-07     
    
    
    
    ****************************