NEXT
User name a-onl
Log entry time 01:44:04 on May 12, 2006
Entry number 173727
keyword=End_of_Run_4648
****************************
Run Number: 4648
End of Run Comment:
Run_type=cosmics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 137 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
raster run
PRESCALE FACTORS:ps1=5000 ps2=10 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 10289 [+]: 4618 [-]: 4698
TIME [0]: 0.601 mins [+]: 0.288 mins [-]: 0.288 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 0.95538 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] :115.9/579829.2 Hz T2[0] :92.4/923.9 Hz T3[0] :126.2/126.2 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] :115.9/579332.8 Hz T2[+] :92.6/926.1 Hz T3[+] :124.0/124.0 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.3/8.3 Hz T8[+] : 0.0/105000.3 Hz T9[+] : 0.0/0.0 Hz
T1[-] :116.3/581431.1 Hz T2[-] :92.3/922.8 Hz T3[-] :127.6/127.6 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.8/8.8 Hz T8[-] : 0.0/104999.6 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 4178/20894559 T2[0] : 3329/33294 T3[0] : 4547/4547 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 309/309 T8[0] : 0/3783750 T9[0] : 1077/1077
T1[+] : 2000/10001376 T2[+] : 1598/15988 T3[+] : 2140/2140 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 144/144 T8[+] : 0/1812684 T9[+] : 0/0
T1[-] : 2007/10037987 T2[-] : 1593/15932 T3[-] : 2203/2203 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 152/152 T8[-] : 0/1812743 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 1.1079 uA BCM x3 : 0.9999 uA BCM x10: 0.9765 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -2010 ppm BCM u3 : -1762 ppm BCM u10: -1965 ppm
BCM d1 : -1726 ppm BCM d3 : -1952 ppm BCM d10: -1990 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:4.053E-05 BCM u3 [0]:3.646E-05 BCM u10[0]:3.498E-05
BCM u1 [+]:1.94E-05 BCM u3 [+]:1.746E-05 BCM u10[+]:1.674E-05
BCM u1 [-]:1.948E-05 BCM u3 [-]:1.752E-05 BCM u10[-]:1.681E-05
BCM d1 [0]:3.931E-05 BCM d3 [0]:3.56E-05 BCM d10[0]:3.54E-05
BCM d1 [+]:1.882E-05 BCM d3 [+]:1.704E-05 BCM d10[+]:1.694E-05
BCM d1 [-]:1.889E-05 BCM d3 [-]:1.71E-05 BCM d10[-]:1.701E-05
****************************