NEXT
User name a-onl
Log entry time 02:30:52 on May 12, 2006
Entry number 173738
keyword=End_of_Run_4650
****************************
Run Number: 4650
End of Run Comment:
Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 136 psi. 1.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
PRESCALE FACTORS:ps1=5000 ps2=1 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 552523 [+]: 248440 [-]: 249115
TIME [0]: 28.997 mins [+]: 14.275 mins [-]: 14.275 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -0.59724 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] :80.4/401974.3 Hz T2[0] :220.6/220.6 Hz T3[0] :37.3/37.3 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] :80.2/401072.3 Hz T2[+] :220.4/220.4 Hz T3[+] :37.3/37.3 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.6/8.6 Hz T8[+] : 0.0/104999.9 Hz T9[+] : 0.0/0.0 Hz
T1[-] :80.5/402723.7 Hz T2[-] :220.8/220.8 Hz T3[-] :37.3/37.3 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.5/8.5 Hz T8[-] : 0.0/105000.0 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 139872/699361642 T2[0] : 383748/383748 T3[0] : 64934/64934 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 14893/14893 T8[0] : 0/182680746 T9[0] : 52027/52027
T1[+] : 68703/343519582 T2[+] : 188750/188750 T3[+] : 31972/31972 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 7358/7358 T8[+] : 0/89932744 T9[+] : 0/0
T1[-] : 68986/344934050 T2[-] : 189125/189125 T3[-] : 31963/31963 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 7293/7293 T8[-] : 0/89932789 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 1.0849 uA BCM x3 : 0.9770 uA BCM x10: 0.9536 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1759 ppm BCM u3 : -1884 ppm BCM u10: -1967 ppm
BCM d1 : -1813 ppm BCM d3 : -1933 ppm BCM d10: -1978 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001917 BCM u3 [0]:0.001721 BCM u10[0]:0.001649
BCM u1 [+]:0.0009423 BCM u3 [+]:0.0008456 BCM u10[+]:0.0008102
BCM u1 [-]:0.0009456 BCM u3 [-]:0.0008488 BCM u10[-]:0.0008134
BCM d1 [0]:0.001858 BCM d3 [0]:0.001679 BCM d10[0]:0.001669
BCM d1 [+]:0.0009128 BCM d3 [+]:0.0008247 BCM d10[+]:0.0008199
BCM d1 [-]:0.0009161 BCM d3 [-]:0.0008279 BCM d10[-]:0.0008232
****************************