NEXT
User name a-onl
Log entry time 02:49:39 on May 12, 2006
Entry number 173741
keyword=End_of_Run_4651
****************************
Run Number: 4651
End of Run Comment:
Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 136 psi. 1.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
PRESCALE FACTORS:ps1=6000 ps2=2 ps3=1 ps4=9999 ps5=9999 ps6=9999 ps7=1 ps8=0
EVENTS[0]: 393358 [+]: 181219 [-]: 182225
TIME [0]: 15.588 mins [+]: 7.670 mins [-]: 7.669 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 0.18567 seconds
(Shouldnt be too big but is also recoverable offline. See also halog 165401)
TRIGGER RATES: PRES/REAL
T1[0] :132.4/794223.3 Hz T2[0] :233.2/466.4 Hz T3[0] :92.4/92.4 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 8.6/8.6 Hz T8[0] : 0.0/105000.0 Hz T9[0] :29.9/29.9 Hz
T1[+] :132.1/792601.8 Hz T2[+] :232.8/465.5 Hz T3[+] :91.8/91.8 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 8.5/8.5 Hz T8[+] : 0.0/105000.0 Hz T9[+] : 0.0/0.0 Hz
T1[-] :132.6/795650.9 Hz T2[-] :233.7/467.4 Hz T3[-] :93.1/93.1 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 8.6/8.6 Hz T8[-] : 0.0/104999.9 Hz T9[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 123802/742813453 T2[0] : 218104/436209 T3[0] : 86453/86453 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 8006/8006 T8[0] : 0/98203385 T9[0] : 27968/27968
T1[+] : 60792/364752294 T2[+] : 107116/214232 T3[+] : 42232/42232 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 3907/3907 T8[+] : 0/48320607 T9[+] : 0/0
T1[-] : 61021/366128908 T2[-] : 107550/215101 T3[-] : 42829/42829 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 3969/3969 T8[-] : 0/48317051 T9[-] : 0/0
AVERAGE CURRENT
BCM x1 : 2.0724 uA BCM x3 : 1.9647 uA BCM x10: 1.9419 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1748 ppm BCM u3 : -1788 ppm BCM u10: -1844 ppm
BCM d1 : -1757 ppm BCM d3 : -1806 ppm BCM d10: -1846 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001946 BCM u3 [0]:0.00184 BCM u10[0]:0.001803
BCM u1 [+]:0.0009556 BCM u3 [+]:0.0009037 BCM u10[+]:0.0008855
BCM u1 [-]:0.0009589 BCM u3 [-]:0.0009068 BCM u10[-]:0.0008887
BCM d1 [0]:0.001931 BCM d3 [0]:0.001835 BCM d10[0]:0.00183
BCM d1 [+]:0.0009486 BCM d3 [+]:0.0009014 BCM d10[+]:0.0008986
BCM d1 [-]:0.0009518 BCM d3 [-]:0.0009046 BCM d10[-]:0.0009019
****************************