Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:55:59 on May 12, 2006

    Entry number 173744

    keyword=End_of_Run_4652
    ****************************
     Run Number: 4652
     End of Run Comment:
    Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 136 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2 -- JUNK
     
    
    PRESCALE FACTORS:ps1=9000   ps2=2   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 3745         [+]: 456          [-]: 443          
    TIME  [0]: 1.675 mins  [+]: 0.816 mins  [-]: 0.815 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         1.07395 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.1/852.5 Hz   T2[0] : 5.3/10.5 Hz   T3[0] : 8.6/8.6  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] : 0.1/855.2 Hz   T2[+] : 5.4/10.7 Hz   T3[+] : 8.6/8.6  Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.6/8.6  Hz   T8[+] : 0.0/105000.1 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] : 0.1/850.2 Hz   T2[-] : 5.2/10.4 Hz   T3[-] : 8.5/8.5  Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.5/8.5  Hz   T8[-] : 0.0/104999.7 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      9/85698    T2[0] :    529/1059     T3[0] :    860/860      T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :    860/860      T8[0] :      0/10555039  T9[0] :   3006/3006     
    T1[+] :      4/41870    T2[+] :    263/526      T3[+] :    422/422      T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :    422/422      T8[+] :      0/5140624  T9[+] :      0/0        
    T1[-] :      4/41596    T2[-] :    254/509      T3[-] :    415/415      T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :    415/415      T8[-] :      0/5137195  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.1320 uA  BCM x3 : 0.0192 uA  BCM x10: -0.0071uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    402.5 ppm     BCM u3 :     3978 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :     1010 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:1.583E-05      BCM u3 [0]:3.941E-06      BCM u10[0]:-5.597E-07     
    BCM u1 [+]:7.705E-06      BCM u3 [+]:1.927E-06      BCM u10[+]:-2.706E-07     
    BCM u1 [-]:7.694E-06      BCM u3 [-]:1.911E-06      BCM u10[-]:-2.725E-07     
    
    BCM d1 [0]:1.071E-05      BCM d3 [0]:-8.874E-08     BCM d10[0]:-8.707E-07     
    BCM d1 [+]:5.21E-06       BCM d3 [+]:-4.26E-08      BCM d10[+]:-4.207E-07     
    BCM d1 [-]:5.196E-06      BCM d3 [-]:-4.39E-08      BCM d10[-]:-4.232E-07     
    
    
    
    ****************************