    keyword=End_of_Run_4653
    ****************************
     Run Number: 4653
     End of Run Comment:
    Run_type=optics,beam_energy=2.079,beam_polarization=%,beam_raster=on,comment_text=GeN_vme config, Reference cell hydrogen. 136 psi. 4.0uA beam. MCC2.5*2.5 raster,daq_mode=GeN,kin_name=,leftarm_p=1.8,leftarm_theta=35.1,rightarm_p=1.32,rightarm_theta=52.0,target_halfwaveplate=out,target_name=,target_polarization=55.2,target_type=Reference Cell H2
     
    
    PRESCALE FACTORS:ps1=9000   ps2=2   ps3=1   ps4=9999   ps5=9999   ps6=9999   ps7=1   ps8=0   
    
    EVENTS[0]: 1375719      [+]: 656660       [-]: 658239       
    TIME  [0]: 30.410 mins  [+]: 14.971 mins  [-]: 14.970 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -0.58586 seconds
     (Shouldnt be too big but is also recoverable offline.  See also halog 165401)
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :-91.3/-821487.6 Hz   T2[0] :506.5/1013.1 Hz   T3[0] :288.7/288.7 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.6/8.6  Hz   T8[0] : 0.0/105000.0 Hz   T9[0] :29.9/29.9 Hz   
    T1[+] :170.0/1529740.5 Hz   T2[+] :505.8/1011.6 Hz   T3[+] :287.4/287.4 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.7/8.7  Hz   T8[+] : 0.0/105000.0 Hz   T9[+] : 0.0/0.0  Hz   
    T1[-] :170.5/1534446.4 Hz   T2[-] :507.2/1014.5 Hz   T3[-] :289.9/289.9 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.4/8.4  Hz   T8[-] : 0.0/104999.9 Hz   T9[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :-166545/-1498903496  T2[0] : 924246/1848493  T3[0] : 526724/526724   T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :  15618/15618    T8[0] :      0/191585205  T9[0] :  54563/54563    
    T1[+] : 152676/1374088531  T2[+] : 454343/908687   T3[+] : 258121/258121   T4[+] :      0/0        T5[+] :      0/0        T6[+] :      0/0        T7[+] :   7798/7798     T8[+] :      0/94316171  T9[+] :      0/0        
    T1[-] : 153140/1378261261  T2[-] : 455610/911221   T3[-] : 260433/260433   T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :   7581/7581     T8[-] :      0/94312425  T9[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 4.0127 uA  BCM x3 : 3.9058 uA  BCM x10: 3.8848 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1490 ppm     BCM u3 :    -1515 ppm     BCM u10:    -1549 ppm     
    BCM d1 :    -1531 ppm     BCM d3 :    -1521 ppm     BCM d10:    -1545 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.007302       BCM u3 [0]:0.007096       BCM u10[0]:0.007031       
    BCM u1 [+]:0.003589       BCM u3 [+]:0.003488       BCM u10[+]:0.003456       
    BCM u1 [-]:0.0036         BCM u3 [-]:0.003498       BCM u10[-]:0.003466       
    
    BCM d1 [0]:0.007341       BCM d3 [0]:0.007157       BCM d10[0]:0.007146       
    BCM d1 [+]:0.003608       BCM d3 [+]:0.003518       BCM d10[+]:0.003512       
    BCM d1 [-]:0.003619       BCM d3 [-]:0.003529       BCM d10[-]:0.003523       
    
    
    
    ****************************