    User name sawatzky

    Log entry time 04:11:18 on May 12, 2006

    Entry number 173758

    keyword=Shift/Run summary (00:00 - 04:00)

    Shift Crew00:00 -- 04:00  B. Sawatzky, B. Craver, H. Yao


    Comments:

    Facility Development time used to test v767 TDCs with BigBite drift chambers under beam conditions.


    Events:
    00:30 Controlled Access to move front chamber to VME ROC20 (v767 TDCs)

    01:30 Requested Beam (1 uA on optics target for raster, BeO postion check)

    01:47 Target change to Hydrogen cell (136 psi) - request 1 uA

    02:30 Request 2 uA on Hydrogen cell (136 psi)

    02:50 Request 4 uA on Hydrogen cell (136 psi)

    03:30 Request 6 uA on Hydrogen cell (136 psi)

    04:00 Request 1 uA on Carbon Foils

    04:10 Hand off to Eugene for CSR/Moeller tests


    Run Summary:
    Beam Energy: 2.075 GeV (Set Value), 2.0780 GeV (Meas)
    Targets: Hydrogen reference cell (136 psi), Optics foils
      Raster: On (2.5mm x 2.5mm in MCC units)
      Neutron Arm Setting: 32 degrees
      BigBite Setting: 52 degrees, 710 A, 140cm from target (Transversity distance)


    4648  Optics: Carbon foils, 1 uA, short run for raster, beam position check.
    4649  Optics: Hydrogen ref. cell (136 psi), 1 uA, short run (beam tripped)
    4650  Optics: Hydrogen ref. cell (136 psi), 1 uA
    4651  Optics: Hydrogen ref. cell (136 psi), 2 uA, Brandon tuned MWDC HVs prior to starting run
    4652  Optics: Hydrogen ref. cell (136 psi), 4 uA, JUNK (beam tripped at start), Brandon tuned MWDC HVs prior to starting run
    4653  Optics: Hydrogen ref. cell (136 psi), 4 uA, (end of run failed)
    4654  JUNK -- Had to restart CODA, rebootede DAQ ROCs
    4655  Optics: Hydrogen ref. cell (136 psi), 6 uA, Brandon tuned MWDC HVs prior to starting run
    4656  Optics: Carbon Foils, 1 uA