     Run Number: 3013
     End of Run Comment:
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=4.057
    beam_raster=on
    leftarm_p=3.728
    leftarm_theta=21.55
    leftarm_colli=out
    rightarm_p=.7272
    rightarm_theta=68.30
    rightarm_colli=out
    comment_text=100uA
     
    
    PRESCALE FACTORS:ps1=500   ps2=20000   ps3=2   ps4=100   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1251435      [+]: 614843       [-]: 615144       
    TIME  [0]: 25.282 mins  [+]: 12.424 mins  [-]: 12.423 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         2.22107 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  94.97%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :27.8/13905.4 Hz   T2[0] :10.3/205432.1 Hz   T3[0] :779.4/1558.9 Hz   T4[0] :10.2/1018.8 Hz   
    T5[0] : 7.5/7.5  Hz   T6[0] :66.0/66.0 Hz   T7[0] : 4.2/4.2  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :27.8/13906.7 Hz   T2[+] :10.3/205423.9 Hz   T3[+] :779.0/1558.1 Hz   T4[+] :10.2/1017.2 Hz   
    T5[+] : 7.6/7.6  Hz   T6[+] :66.2/66.2 Hz   T7[+] : 4.2/4.2  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :27.8/13904.5 Hz   T2[-] :10.3/205420.4 Hz   T3[-] :779.8/1559.6 Hz   T4[-] :10.2/1020.5 Hz   
    T5[-] : 7.6/7.6  Hz   T6[-] :65.9/65.9 Hz   T7[-] :825.3/825.3 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42186/21093060  T2[0] :  15580/311619094  T3[0] :1182343/2364686  T4[0] :  15454/1545454  
    T5[0] :  11441/11441    T6[0] : 100168/100168   T7[0] :   6384/6384     T8[0] :     23/1553301  
    
    T1[+] :  20732/10366411  T2[+] :   7656/153128468  T3[+] : 580708/1161417  T4[+] :   7582/758221   
    T5[+] :   5631/5631     T6[+] :  49353/49353    T7[+] :   3143/3143     T8[+] :     11/763317   
    
    T1[-] :  20728/10364309  T2[-] :   7655/153119261  T3[-] : 581261/1162522  T4[-] :   7606/760674   
    T5[-] :   5629/5629     T6[-] :  49136/49136    T7[-] : 615144/615144   T8[-] :     11/763284   
    
    
    AVERAGE CURRENT
    BCM x1 : 94.0086uA  BCM x3 : 93.7939uA  BCM x10: 54.5703uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -14.48 ppm     BCM u3 :   -14.17 ppm     BCM u10:    14.42 ppm     
    BCM d1 :   -15.36 ppm     BCM d3 :   -15.49 ppm     BCM d10:    -4.15 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1432         BCM u3 [0]:0.143          BCM u10[0]:0.0897         
    BCM u1 [+]:0.07035        BCM u3 [+]:0.07024        BCM u10[+]:0.04113        
    BCM u1 [-]:0.07035        BCM u3 [-]:0.07024        BCM u10[-]:0.04113        
    
    BCM d1 [0]:0.142          BCM d3 [0]:0.1416         BCM d10[0]:0.07586        
    BCM d1 [+]:0.06978        BCM d3 [+]:0.06957        BCM d10[+]:0.03727        
    BCM d1 [-]:0.06978        BCM d3 [-]:0.06957        BCM d10[-]:0.03727        
    
    
    
    
    Right S1 scintillators
    S1R [0]:9.69E+05       S1R [1]:8.332E+06      S1R [2]:6.714E+06      
    S1R [3]:4.773E+06      S1R [4]:1.593E+07      S1R [5]:3.077E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:711.6 Hz   S1L [1]:18415.6 Hz   S1L [2]:4342.0 Hz   
    S1L [3]:3332.1 Hz   S1L [4]:2665.2 Hz   S1L [5]:6529.2 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:7538842.200000   S1L [1]:195098490.000000   S1L [2]:46000106.000000   
    S1L [3]:35301414.000000   S1L [4]:28236124.000000   S1L [5]:69172129.000000   
    S1R [0]:6767843.400000   S1R [1]:58191460.000000   S1R [2]:46890939.000000   
    S1R [3]:33335040.000000   S1R [4]:111261200.000000   S1R [5]:21492382.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.019E+07      S2  [1]:1.145E+07      S2  [2]:1.552E+07      S2  [3]:2.385E+07      
    S2  [4]:3.052E+07      S2  [5]:3.267E+07      S2  [6]:3.023E+07      S2  [7]:3.26E+07       
    S2  [8]:3.108E+07      S2  [9]:2.935E+07      S2  [10]:3.014E+07      S2  [11]:3.017E+07      
    S2  [12]:4.137E+07      S2  [13]:2.596E+07      S2  [14]:1.832E+07      S2  [15]:1.391E+07      
    S2  [16]:1.005E+07      S2  [17]:1.355E+07      S2  [18]:1.98E+07       S2  [19]:2.393E+07      
    S2  [20]:3.081E+07      S2  [21]:3.268E+07      S2  [22]:3.117E+07      S2  [23]:3.359E+07      
    S2  [24]:3.017E+07      S2  [25]:3.062E+07      S2  [26]:2.774E+07      S2  [27]:2.751E+07      
    S2  [28]:2.491E+07      S2  [29]:2.201E+07      S2  [30]:2.119E+07      S2  [31]:1.279E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:6718.4 Hz   S2  [1]:7546.8 Hz   S2  [2]:10233.7 Hz   S2  [3]:15723.4 Hz   
    S2  [4]:20118.0 Hz   S2  [5]:21538.8 Hz   S2  [6]:19931.6 Hz   S2  [7]:21490.7 Hz   
    S2  [8]:20489.0 Hz   S2  [9]:19350.0 Hz   S2  [10]:19872.2 Hz   S2  [11]:19892.4 Hz   
    S2  [12]:27273.3 Hz   S2  [13]:17112.2 Hz   S2  [14]:12079.2 Hz   S2  [15]:9168.0 Hz   
    S2  [16]:6628.4 Hz   S2  [17]:8932.4 Hz   S2  [18]:13052.6 Hz   S2  [19]:15774.6 Hz   
    S2  [20]:20308.1 Hz   S2  [21]:21542.4 Hz   S2  [22]:20546.6 Hz   S2  [23]:22142.7 Hz   
    S2  [24]:19888.2 Hz   S2  [25]:20183.8 Hz   S2  [26]:18284.7 Hz   S2  [27]:18136.7 Hz   
    S2  [28]:16420.2 Hz   S2  [29]:14510.2 Hz   S2  [30]:13967.6 Hz   S2  [31]:8429.3 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:71176148.000000   S2  [ 1]:79952480.000000   S2  [ 2]:108417510.000000   
    S2  [ 3]:166576760.000000   S2  [ 4]:213134400.000000   S2  [ 5]:228186000.000000   
    S2  [ 6]:211159520.000000   S2  [ 7]:227676730.000000   S2  [ 8]:217063890.000000   
    S2  [ 9]:204998060.000000   S2  [10]:210529490.000000   S2  [11]:210744130.000000   
    S2  [12]:288938460.000000   S2  [13]:181289740.000000   S2  [14]:127969590.000000   
    S2  [15]:97127854.000000   S2  [16]:70222451.000000   S2  [17]:94631175.000000   
    S2  [18]:138281410.000000   S2  [19]:167119630.000000   S2  [20]:215147990.000000   
    S2  [21]:228224100.000000   S2  [22]:217674110.000000   S2  [23]:234584360.000000   
    S2  [24]:210699470.000000   S2  [25]:213831390.000000   S2  [26]:193711370.000000   
    S2  [27]:192144020.000000   S2  [28]:173958440.000000   S2  [29]:153723850.000000   
    S2  [30]:147974980.000000   S2  [31]:89301357.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 54940497.000000   
    Right arm S2m  : 174567840.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:7.746E+06      S1R [1]:1.069E+07      S1R [2]:1.636E+07      
    S1R [3]:1.339E+07      S1R [4]:1.603E+07      S1R [5]:9.832E+06      
    S1L [0]:7.09E+06       S1L [1]:8.844E+06      S1L [2]:1.344E+07      
    S1L [3]:1.406E+07      S1L [4]:1.537E+07      S1L [5]:1.036E+07      
    
    
    Left arm S1 scintillators rates
    S1R [0]:5106.7 Hz   S1R [1]:7047.3 Hz   S1R [2]:10784.2 Hz   
    S1R [3]:8824.3 Hz   S1R [4]:10567.5 Hz   S1R [5]:6481.6 Hz   
    S1L [0]:4674.0 Hz   S1L [1]:5830.2 Hz   S1L [2]:8860.5 Hz   
    S1L [3]:9269.0 Hz   S1L [4]:10135.2 Hz   S1L [5]:6831.8 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:54101115.0    S1R [1]:74660774.0    S1R [2]:114249590.0    
    S1R [3]:93486260.0    S1R [4]:111954080.0    S1R [5]:68667345.0    
    S1L [0]:49517732.0    S1L [1]:61765818.0    S1L [2]:93869444.0    
    S1L [3]:98198011.0    S1L [4]:107374150.0    S1L [5]:72377914.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.082E+07      S2R [1]:2.083E+07      S2R [2]:3.003E+07      
    S2R [3]:4.792E+07      S2R [4]:4.745E+07      S2R [5]:3.407E+07      
    S2L [0]:3.96E+07       S2L [1]:2.407E+07      S2L [2]:3.995E+07      
    S2L [3]:3.352E+07      S2L [4]:3.249E+07      S2L [5]:3.879E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:13723.5 Hz   S2R [1]:13728.9 Hz   S2R [2]:19796.0 Hz   
    S2R [3]:31589.1 Hz   S2R [4]:31281.6 Hz   S2R [5]:22461.5 Hz   
    S2L [0]:26104.4 Hz   S2L [1]:15865.8 Hz   S2L [2]:26337.8 Hz   
    S2L [3]:22100.3 Hz   S2L [4]:21419.4 Hz   S2L [5]:25569.7 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:145388930.0    S2R [1]:145446400.0    S2R [2]:209722660.0    
    S2R [3]:334660500.0    S2R [4]:331402910.0    S2R [5]:237961920.0    
    S2L [0]:276555550.0    S2L [1]:168085520.0    S2L [2]:279028090.0    
    S2L [3]:234134400.0    S2L [4]:226921460.0    S2L [5]:270890490.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.821E+07      GasC  [1]:1.378E+07      GasC  [2]:1.564E+07      
    GasC  [3]:1.543E+07      GasC  [4]:1.656E+07      GasC  [5]:1.527E+07      
    GasC  [6]:1.508E+07      GasC  [7]:1.52E+07       GasC  [8]:1.306E+07      
    GasC  [9]:3.645E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:12004.5 Hz   GasC  [1]:9082.7 Hz   GasC  [2]:10307.7 Hz   
    GasC  [3]:10171.9 Hz   GasC  [4]:10915.7 Hz   GasC  [5]:10067.2 Hz   
    GasC  [6]:9942.0 Hz   GasC  [7]:10021.3 Hz   GasC  [8]:8606.6 Hz   
    GasC  [9]:24032.5 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:127178510.0 GasC  [1]:96223347.0 GasC  [2]:109201710.0 
    GasC  [3]:107762690.0 GasC  [4]:115643260.0 GasC  [5]:106653680.0 
    GasC  [6]:105327670.0 GasC  [7]:106168000.0 GasC  [8]:91179808.0 
    GasC  [9]:254604590.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  83351850.000000   
    Left S2 :   238349900.000000   
    Gas Cerenkov :  121994330.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3013 at Mon Apr 30 07:44:42 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.72809
    Left Arm arm angle : 21.5458
    Right Arm D1 momentum : 0.7272
    Right Arm arm angle : 68.3281
    HALLA:p : 4051.27
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 4051.27
    Left Arm Top VDC Current : -2.63672
    Left Arm Bottom VDC Current : 3.02734
    Left Arm Q1 momentum : 3.72808
    Left Arm Q1 power supply : 2804.75
    Left Arm Q1 gauss meter : -0.23635
    Left Arm Q2 gauss meter : 0.8447
    Left Arm Q2 power supply current : 1605.37
    Left Arm Q2 momentum : 3.72822
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1357.55
    Left Arm D1 momentum : 3.72809
    Left Arm D1 NMR : 1.38101
    Left Arm Q3 gauss meter : -0.7407
    Left Arm Q3 power supply current : 1484.16
    Left Arm Q3 momentum : 3.72793
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.727159
    Right Arm Q1 power supply : 546.777
    Right Arm Q1 gauss meter : 0.013804
    Right Arm Q2 power supply current : 312.958
    Right Arm Q2 momentum : 0.727189
    Right Arm Q2 gauss meter : -0.16544
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 249.94
    Right Arm D1 momentum : 0.7272
    Right Arm D1 NMR : 0.269855
    Right Arm Q3 power supply current : 289.369
    Right Arm Q3 momentum : 0.727226
    Right Arm Q3 gauss meter : -0.13027
    Right Arm Q3 power supply polarity : enabled