Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 08:15:01 on April 30, 2007

    Entry number 200609

    keyword=End_of_Run_3014
    ****************************
     Run Number: 3014
     End of Run Comment:
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=4.057
    beam_raster=on
    leftarm_p=3.728
    leftarm_theta=21.55
    leftarm_colli=out
    rightarm_p=.7272
    rightarm_theta=68.30
    rightarm_colli=out
    comment_text=100uA
     
    
    PRESCALE FACTORS:ps1=500   ps2=20000   ps3=2   ps4=100   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1251975      [+]: 612034       [-]: 612417       
    TIME  [0]: 29.608 mins  [+]: 14.497 mins  [-]: 14.501 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         8.74790 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  95.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :23.8/11903.9 Hz   T2[0] : 8.8/176776.1 Hz   T3[0] :664.9/1329.8 Hz   T4[0] : 8.7/868.2 Hz   
    T5[0] : 7.0/7.0  Hz   T6[0] :56.5/56.5 Hz   T7[0] : 3.6/3.6  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :23.8/11887.7 Hz   T2[+] : 8.8/176570.5 Hz   T3[+] :663.8/1327.5 Hz   T4[+] : 8.7/865.6 Hz   
    T5[+] : 6.9/6.9  Hz   T6[+] :56.4/56.4 Hz   T7[+] : 3.7/3.7  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :23.8/11892.7 Hz   T2[-] : 8.8/176563.3 Hz   T3[-] :664.1/1328.2 Hz   T4[-] : 8.7/868.4 Hz   
    T5[-] : 7.0/7.0  Hz   T6[-] :56.5/56.5 Hz   T7[-] :703.9/703.9 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42293/21146859  T2[0] :  15701/314035797  T3[0] :1181151/2362302  T4[0] :  15422/1542275  
    T5[0] :  12347/12347    T6[0] : 100427/100427   T7[0] :   6467/6467     T8[0] :     27/1819096  
    
    T1[+] :  20680/10340301  T2[+] :   7679/153587159  T3[+] : 577374/1154749  T4[+] :   7529/752919   
    T5[+] :   6019/6019     T6[+] :  49024/49024    T7[+] :   3190/3190     T8[+] :     13/890711   
    
    T1[-] :  20694/10347162  T2[-] :   7680/153617164  T3[-] : 577804/1155609  T4[-] :   7555/755570   
    T5[-] :   6069/6069     T6[-] :  49186/49186    T7[-] : 612417/612417   T8[-] :     13/890921   
    
    
    AVERAGE CURRENT
    BCM x1 : 80.3729uA  BCM x3 : 80.1993uA  BCM x10: 50.1652uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    86.92 ppm     BCM u3 :    86.52 ppm     BCM u10:     94.3 ppm     
    BCM d1 :    87.17 ppm     BCM d3 :    86.18 ppm     BCM d10:    88.99 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1434         BCM u3 [0]:0.1432         BCM u10[0]:0.1001         
    BCM u1 [+]:0.07011        BCM u3 [+]:0.07001        BCM u10[+]:0.04426        
    BCM u1 [-]:0.07011        BCM u3 [-]:0.07001        BCM u10[-]:0.04427        
    
    BCM d1 [0]:0.1422         BCM d3 [0]:0.1418         BCM d10[0]:0.07809        
    BCM d1 [+]:0.06954        BCM d3 [+]:0.06934        BCM d10[+]:0.0382         
    BCM d1 [-]:0.06954        BCM d3 [-]:0.06934        BCM d10[-]:0.0382         
    
    
    
    
    Right S1 scintillators
    S1R [0]:9.758E+05      S1R [1]:8.333E+06      S1R [2]:6.77E+06       
    S1R [3]:4.789E+06      S1R [4]:1.599E+07      S1R [5]:3.07E+06       
    
    
    Right S1 scintillators rates 
    S1L [0]:607.4 Hz   S1L [1]:15906.9 Hz   S1L [2]:3719.9 Hz   
    S1L [3]:2852.6 Hz   S1L [4]:2287.8 Hz   S1L [5]:5574.8 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:7526370.300000   S1L [1]:197107860.000000   S1L [2]:46094676.000000   
    S1L [3]:35347366.000000   S1L [4]:28348914.000000   S1L [5]:69079219.000000   
    S1R [0]:6806792.000000   S1R [1]:58125663.000000   S1R [2]:47225476.000000   
    S1R [3]:33404481.000000   S1R [4]:111556580.000000   S1R [5]:21414844.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.031E+07      S2  [1]:1.155E+07      S2  [2]:1.564E+07      S2  [3]:2.402E+07      
    S2  [4]:3.071E+07      S2  [5]:3.287E+07      S2  [6]:3.041E+07      S2  [7]:3.283E+07      
    S2  [8]:3.128E+07      S2  [9]:2.955E+07      S2  [10]:3.035E+07      S2  [11]:3.038E+07      
    S2  [12]:4.164E+07      S2  [13]:2.617E+07      S2  [14]:1.848E+07      S2  [15]:1.403E+07      
    S2  [16]:1.017E+07      S2  [17]:1.369E+07      S2  [18]:1.999E+07      S2  [19]:2.41E+07       
    S2  [20]:3.102E+07      S2  [21]:3.289E+07      S2  [22]:3.137E+07      S2  [23]:3.393E+07      
    S2  [24]:3.037E+07      S2  [25]:3.083E+07      S2  [26]:2.792E+07      S2  [27]:2.771E+07      
    S2  [28]:2.507E+07      S2  [29]:2.218E+07      S2  [30]:2.137E+07      S2  [31]:1.29E+07       
    
    Right arm S2 scintillators rates
    S2  [0]:5805.0 Hz   S2  [1]:6501.5 Hz   S2  [2]:8801.9 Hz   S2  [3]:13519.6 Hz   
    S2  [4]:17290.0 Hz   S2  [5]:18503.2 Hz   S2  [6]:17117.9 Hz   S2  [7]:18480.3 Hz   
    S2  [8]:17610.4 Hz   S2  [9]:16634.3 Hz   S2  [10]:17086.1 Hz   S2  [11]:17099.0 Hz   
    S2  [12]:23442.4 Hz   S2  [13]:14732.9 Hz   S2  [14]:10400.2 Hz   S2  [15]:7899.9 Hz   
    S2  [16]:5727.5 Hz   S2  [17]:7706.5 Hz   S2  [18]:11252.9 Hz   S2  [19]:13568.1 Hz   
    S2  [20]:17461.5 Hz   S2  [21]:18516.0 Hz   S2  [22]:17660.2 Hz   S2  [23]:19098.4 Hz   
    S2  [24]:17094.9 Hz   S2  [25]:17356.1 Hz   S2  [26]:15717.7 Hz   S2  [27]:15597.1 Hz   
    S2  [28]:14113.4 Hz   S2  [29]:12483.0 Hz   S2  [30]:12032.1 Hz   S2  [31]:7259.6 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:71931354.000000   S2  [ 1]:80561801.000000   S2  [ 2]:109067180.000000   
    S2  [ 3]:167526130.000000   S2  [ 4]:214245780.000000   S2  [ 5]:229278880.000000   
    S2  [ 6]:212114240.000000   S2  [ 7]:228996180.000000   S2  [ 8]:218216790.000000   
    S2  [ 9]:206121280.000000   S2  [10]:211719170.000000   S2  [11]:211879460.000000   
    S2  [12]:290482150.000000   S2  [13]:182559970.000000   S2  [14]:128872070.000000   
    S2  [15]:97890190.000000   S2  [16]:70971637.000000   S2  [17]:95493827.000000   
    S2  [18]:139438660.000000   S2  [19]:168127310.000000   S2  [20]:216370970.000000   
    S2  [21]:229437900.000000   S2  [22]:218833630.000000   S2  [23]:236654840.000000   
    S2  [24]:211829210.000000   S2  [25]:215065780.000000   S2  [26]:194763670.000000   
    S2  [27]:193268350.000000   S2  [28]:174883440.000000   S2  [29]:154680910.000000   
    S2  [30]:149093410.000000   S2  [31]:89956002.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 55169854.000000   
    Right arm S2m  : 175635380.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:7.981E+06      S1R [1]:1.091E+07      S1R [2]:1.66E+07       
    S1R [3]:1.358E+07      S1R [4]:1.624E+07      S1R [5]:9.958E+06      
    S1L [0]:7.307E+06      S1L [1]:9.046E+06      S1L [2]:1.367E+07      
    S1L [3]:1.428E+07      S1L [4]:1.556E+07      S1L [5]:1.051E+07      
    
    
    Left arm S1 scintillators rates
    S1R [0]:4492.4 Hz   S1R [1]:6142.3 Hz   S1R [2]:9342.0 Hz   
    S1R [3]:7641.7 Hz   S1R [4]:9142.7 Hz   S1R [5]:5605.4 Hz   
    S1L [0]:4113.5 Hz   S1L [1]:5092.3 Hz   S1L [2]:7692.4 Hz   
    S1L [3]:8036.0 Hz   S1L [4]:8759.7 Hz   S1L [5]:5917.2 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:55666363.0    S1R [1]:76111550.0    S1R [2]:115760430.0    
    S1R [3]:94690846.0    S1R [4]:113290610.0    S1R [5]:69459016.0    
    S1L [0]:50971348.0    S1L [1]:63101022.0    S1L [2]:95319647.0    
    S1L [3]:99576188.0    S1L [4]:108544930.0    S1L [5]:73322158.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.123E+07      S2R [1]:2.123E+07      S2R [2]:3.048E+07      
    S2R [3]:4.856E+07      S2R [4]:4.808E+07      S2R [5]:3.466E+07      
    S2L [0]:4.033E+07      S2L [1]:2.443E+07      S2L [2]:4.045E+07      
    S2L [3]:3.399E+07      S2L [4]:3.293E+07      S2L [5]:3.935E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:11951.2 Hz   S2R [1]:11953.1 Hz   S2R [2]:17155.2 Hz   
    S2R [3]:27337.7 Hz   S2R [4]:27065.5 Hz   S2R [5]:19512.1 Hz   
    S2L [0]:22699.8 Hz   S2L [1]:13752.7 Hz   S2L [2]:22771.1 Hz   
    S2L [3]:19131.2 Hz   S2L [4]:18538.4 Hz   S2L [5]:22148.0 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:148091890.0    S2R [1]:148114840.0    S2R [2]:212576230.0    
    S2R [3]:338751240.0    S2R [4]:335377600.0    S2R [5]:241781450.0    
    S2L [0]:281281480.0    S2L [1]:170413760.0    S2L [2]:282164280.0    
    S2L [3]:237061100.0    S2L [4]:229715980.0    S2L [5]:274443180.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.871E+07      GasC  [1]:1.413E+07      GasC  [2]:1.606E+07      
    GasC  [3]:1.583E+07      GasC  [4]:1.702E+07      GasC  [5]:1.57E+07       
    GasC  [6]:1.551E+07      GasC  [7]:1.562E+07      GasC  [8]:1.346E+07      
    GasC  [9]:3.479E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:10530.8 Hz   GasC  [1]:7953.4 Hz   GasC  [2]:9039.1 Hz   
    GasC  [3]:8912.0 Hz   GasC  [4]:9582.4 Hz   GasC  [5]:8836.2 Hz   
    GasC  [6]:8728.9 Hz   GasC  [7]:8795.5 Hz   GasC  [8]:7577.6 Hz   
    GasC  [9]:19582.5 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:130490510.0 GasC  [1]:98553373.0 GasC  [2]:112006830.0 
    GasC  [3]:110431230.0 GasC  [4]:118738970.0 GasC  [5]:109492130.0 
    GasC  [6]:108163280.0 GasC  [7]:108987740.0 GasC  [8]:93896764.0 
    GasC  [9]:242653120.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  84651175.000000   
    Left S2 :   241647750.000000   
    Gas Cerenkov :  123341390.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3014 at Mon Apr 30 08:14:59 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.72808
    Left Arm arm angle : 21.5458
    Right Arm D1 momentum : 0.7272
    Right Arm arm angle : 68.3281
    HALLA:p : 4051.27
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 4051.27
    Left Arm Top VDC Current : 3.75977
    Left Arm Bottom VDC Current : 3.07617
    Left Arm Q1 momentum : 3.72808
    Left Arm Q1 power supply : 2804.75
    Left Arm Q1 gauss meter : -0.23635
    Left Arm Q2 gauss meter : 0.8447
    Left Arm Q2 power supply current : 1605.38
    Left Arm Q2 momentum : 3.72823
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1357.54
    Left Arm D1 momentum : 3.72808
    Left Arm D1 NMR : 1.38101
    Left Arm Q3 gauss meter : -0.7406
    Left Arm Q3 power supply current : 1484.14
    Left Arm Q3 momentum : 3.72789
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.727159
    Right Arm Q1 power supply : 546.777
    Right Arm Q1 gauss meter : 0.013801
    Right Arm Q2 power supply current : 312.954
    Right Arm Q2 momentum : 0.727179
    Right Arm Q2 gauss meter : -0.16543
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 249.94
    Right Arm D1 momentum : 0.7272
    Right Arm D1 NMR : 0.269855
    Right Arm Q3 power supply current : 289.391
    Right Arm Q3 momentum : 0.727279
    Right Arm Q3 gauss meter : -0.13024
    Right Arm Q3 power supply polarity : enabled