    keyword=End_of_Run_3015
    ****************************
     Run Number: 3015
     End of Run Comment:
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=4.057
    beam_raster=on
    leftarm_p=3.728
    leftarm_theta=21.55
    leftarm_colli=out
    rightarm_p=.7272
    rightarm_theta=68.30
    rightarm_colli=out
    comment_text=100uA
     
    
    PRESCALE FACTORS:ps1=500   ps2=20000   ps3=2   ps4=100   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1251890      [+]: 614503       [-]: 612816       
    TIME  [0]: 25.282 mins  [+]: 12.395 mins  [-]: 12.397 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         5.54589 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  94.96%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :27.8/13895.7 Hz   T2[0] :10.3/205467.7 Hz   T3[0] :779.6/1559.3 Hz   T4[0] :10.2/1017.0 Hz   
    T5[0] : 7.5/7.5  Hz   T6[0] :66.4/66.4 Hz   T7[0] : 4.3/4.3  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :27.8/13898.1 Hz   T2[+] :10.3/205473.7 Hz   T3[+] :780.5/1561.0 Hz   T4[+] :10.2/1017.3 Hz   
    T5[+] : 7.4/7.4  Hz   T6[+] :66.1/66.1 Hz   T7[+] : 4.3/4.3  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :27.8/13889.2 Hz   T2[-] :10.3/205385.6 Hz   T3[-] :778.2/1556.4 Hz   T4[-] :10.2/1016.2 Hz   
    T5[-] : 7.6/7.6  Hz   T6[-] :66.6/66.6 Hz   T7[-] :823.9/823.9 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42156/21078345  T2[0] :  15583/311673182  T3[0] :1182611/2365223  T4[0] :  15427/1542753  
    T5[0] :  11399/11399    T6[0] : 100684/100684   T7[0] :   6565/6565     T8[0] :     23/1553302  
    
    T1[+] :  20672/10336157  T2[+] :   7640/152813029  T3[+] : 580459/1160919  T4[+] :   7566/756606   
    T5[+] :   5523/5523     T6[+] :  49172/49172    T7[+] :   3182/3182     T8[+] :     11/761560   
    
    T1[-] :  20662/10331333  T2[-] :   7638/152773792  T3[-] : 578864/1157729  T4[-] :   7559/755920   
    T5[-] :   5658/5658     T6[-] :  49511/49511    T7[-] : 612816/612816   T8[-] :     11/761691   
    
    
    AVERAGE CURRENT
    BCM x1 : 93.8905uA  BCM x3 : 93.6524uA  BCM x10: 57.1908uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    166.6 ppm     BCM u3 :    165.4 ppm     BCM u10:    155.4 ppm     
    BCM d1 :    166.2 ppm     BCM d3 :    164.1 ppm     BCM d10:    160.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1429         BCM u3 [0]:0.1427         BCM u10[0]:0.09793        
    BCM u1 [+]:0.07007        BCM u3 [+]:0.06997        BCM u10[+]:0.0422         
    BCM u1 [-]:0.07006        BCM u3 [-]:0.06996        BCM u10[-]:0.04219        
    
    BCM d1 [0]:0.1419         BCM d3 [0]:0.1414         BCM d10[0]:0.07557        
    BCM d1 [+]:0.06956        BCM d3 [+]:0.06931        BCM d10[+]:0.03705        
    BCM d1 [-]:0.06955        BCM d3 [-]:0.0693         BCM d10[-]:0.03704        
    
    
    
    
    Right S1 scintillators
    S1R [0]:9.696E+05      S1R [1]:8.306E+06      S1R [2]:6.763E+06      
    S1R [3]:4.775E+06      S1R [4]:1.591E+07      S1R [5]:3.064E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:707.3 Hz   S1L [1]:18528.4 Hz   S1L [2]:4344.3 Hz   
    S1L [3]:3326.5 Hz   S1L [4]:2668.1 Hz   S1L [5]:6520.3 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:7505673.000000   S1L [1]:196625690.000000   S1L [2]:46101778.000000   
    S1L [3]:35301414.000000   S1L [4]:28314349.000000   S1L [5]:69193666.000000   
    S1R [0]:6783441.300000   S1R [1]:58107449.000000   S1R [2]:47312052.000000   
    S1R [3]:33402292.000000   S1R [4]:111302240.000000   S1R [5]:21432622.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.021E+07      S2  [1]:1.145E+07      S2  [2]:1.553E+07      S2  [3]:2.386E+07      
    S2  [4]:3.052E+07      S2  [5]:3.265E+07      S2  [6]:3.023E+07      S2  [7]:3.26E+07       
    S2  [8]:3.106E+07      S2  [9]:2.935E+07      S2  [10]:3.014E+07      S2  [11]:3.015E+07      
    S2  [12]:4.136E+07      S2  [13]:2.597E+07      S2  [14]:1.833E+07      S2  [15]:1.392E+07      
    S2  [16]:1.008E+07      S2  [17]:1.357E+07      S2  [18]:1.982E+07      S2  [19]:2.394E+07      
    S2  [20]:3.082E+07      S2  [21]:3.267E+07      S2  [22]:3.118E+07      S2  [23]:3.356E+07      
    S2  [24]:3.015E+07      S2  [25]:3.062E+07      S2  [26]:2.773E+07      S2  [27]:2.751E+07      
    S2  [28]:2.49E+07       S2  [29]:2.202E+07      S2  [30]:2.12E+07       S2  [31]:1.279E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:6730.4 Hz   S2  [1]:7551.3 Hz   S2  [2]:10237.8 Hz   S2  [3]:15729.4 Hz   
    S2  [4]:20117.3 Hz   S2  [5]:21526.3 Hz   S2  [6]:19929.6 Hz   S2  [7]:21490.0 Hz   
    S2  [8]:20476.4 Hz   S2  [9]:19349.4 Hz   S2  [10]:19872.2 Hz   S2  [11]:19876.7 Hz   
    S2  [12]:27264.8 Hz   S2  [13]:17120.1 Hz   S2  [14]:12085.7 Hz   S2  [15]:9175.0 Hz   
    S2  [16]:6642.1 Hz   S2  [17]:8944.8 Hz   S2  [18]:13068.6 Hz   S2  [19]:15783.9 Hz   
    S2  [20]:20314.6 Hz   S2  [21]:21536.2 Hz   S2  [22]:20553.2 Hz   S2  [23]:22122.5 Hz   
    S2  [24]:19876.9 Hz   S2  [25]:20187.4 Hz   S2  [26]:18283.8 Hz   S2  [27]:18136.2 Hz   
    S2  [28]:16417.8 Hz   S2  [29]:14515.4 Hz   S2  [30]:13974.3 Hz   S2  [31]:8432.3 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:71423590.000000   S2  [ 1]:80134788.000000   S2  [ 2]:108644830.000000   
    S2  [ 3]:166921910.000000   S2  [ 4]:213486940.000000   S2  [ 5]:228439160.000000   
    S2  [ 6]:211495230.000000   S2  [ 7]:228054000.000000   S2  [ 8]:217298000.000000   
    S2  [ 9]:205337380.000000   S2  [10]:210885650.000000   S2  [11]:210934010.000000   
    S2  [12]:289337250.000000   S2  [13]:181679710.000000   S2  [14]:128254860.000000   
    S2  [15]:97365690.000000   S2  [16]:70486626.000000   S2  [17]:94922712.000000   
    S2  [18]:138685440.000000   S2  [19]:167500570.000000   S2  [20]:215581030.000000   
    S2  [21]:228544130.000000   S2  [22]:218112430.000000   S2  [23]:234766440.000000   
    S2  [24]:210935750.000000   S2  [25]:214231100.000000   S2  [26]:194029270.000000   
    S2  [27]:192463660.000000   S2  [28]:174227520.000000   S2  [29]:154038800.000000   
    S2  [30]:148296310.000000   S2  [31]:89483916.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 55115222.000000   
    Right arm S2m  : 174874950.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:7.757E+06      S1R [1]:1.071E+07      S1R [2]:1.637E+07      
    S1R [3]:1.338E+07      S1R [4]:1.61E+07       S1R [5]:9.835E+06      
    S1L [0]:7.104E+06      S1L [1]:8.85E+06       S1L [2]:1.345E+07      
    S1L [3]:1.406E+07      S1L [4]:1.537E+07      S1L [5]:1.036E+07      
    
    
    Left arm S1 scintillators rates
    S1R [0]:5114.0 Hz   S1R [1]:7060.3 Hz   S1R [2]:10794.0 Hz   
    S1R [3]:8820.6 Hz   S1R [4]:10612.1 Hz   S1R [5]:6483.9 Hz   
    S1L [0]:4683.2 Hz   S1L [1]:5834.2 Hz   S1L [2]:8868.4 Hz   
    S1L [3]:9268.6 Hz   S1L [4]:10134.6 Hz   S1L [5]:6832.3 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:54270021.0    S1R [1]:74924465.0    S1R [2]:114546510.0    
    S1R [3]:93604567.0    S1R [4]:112616390.0    S1R [5]:68807372.0    
    S1L [0]:49698440.0    S1L [1]:61912709.0    S1L [2]:94112108.0    
    S1L [3]:98359112.0    S1L [4]:107549780.0    S1L [5]:72504916.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.087E+07      S2R [1]:2.086E+07      S2R [2]:3.003E+07      
    S2R [3]:4.806E+07      S2R [4]:4.747E+07      S2R [5]:3.412E+07      
    S2L [0]:3.962E+07      S2L [1]:2.408E+07      S2L [2]:3.998E+07      
    S2L [3]:3.359E+07      S2L [4]:3.25E+07       S2L [5]:3.871E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:13759.1 Hz   S2R [1]:13752.7 Hz   S2R [2]:19795.1 Hz   
    S2R [3]:31685.2 Hz   S2R [4]:31292.7 Hz   S2R [5]:22490.5 Hz   
    S2L [0]:26121.7 Hz   S2L [1]:15873.9 Hz   S2L [2]:26357.0 Hz   
    S2L [3]:22145.5 Hz   S2L [4]:21424.6 Hz   S2L [5]:25520.7 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:146012610.0    S2R [1]:145944760.0    S2R [2]:210067620.0    
    S2R [3]:336246560.0    S2R [4]:332081590.0    S2R [5]:238671860.0    
    S2L [0]:277206330.0    S2L [1]:168455890.0    S2L [2]:279702600.0    
    S2L [3]:235010230.0    S2L [4]:227359780.0    S2L [5]:270828320.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.818E+07      GasC  [1]:1.377E+07      GasC  [2]:1.566E+07      
    GasC  [3]:1.544E+07      GasC  [4]:1.655E+07      GasC  [5]:1.528E+07      
    GasC  [6]:1.508E+07      GasC  [7]:1.52E+07       GasC  [8]:1.306E+07      
    GasC  [9]:3.189E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:11984.6 Hz   GasC  [1]:9076.5 Hz   GasC  [2]:10322.4 Hz   
    GasC  [3]:10181.9 Hz   GasC  [4]:10910.5 Hz   GasC  [5]:10072.5 Hz   
    GasC  [6]:9944.4 Hz   GasC  [7]:10020.7 Hz   GasC  [8]:8607.7 Hz   
    GasC  [9]:21024.1 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:127181970.0 GasC  [1]:96320666.0 GasC  [2]:109542190.0 
    GasC  [3]:108051400.0 GasC  [4]:115783120.0 GasC  [5]:106889950.0 
    GasC  [6]:105531460.0 GasC  [7]:106340860.0 GasC  [8]:91345456.0 
    GasC  [9]:223109520.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  83575533.000000   
    Left S2 :   238965680.000000   
    Gas Cerenkov :  119009660.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3015 at Mon Apr 30 08:40:57 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.72809
    Left Arm arm angle : 21.5458
    Right Arm D1 momentum : 0.7272
    Right Arm arm angle : 68.3281
    HALLA:p : 4051.27
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 4051.27
    Left Arm Top VDC Current : -3.27148
    Left Arm Bottom VDC Current : 2.73438
    Left Arm Q1 momentum : 3.72808
    Left Arm Q1 power supply : 2804.75
    Left Arm Q1 gauss meter : -0.23636
    Left Arm Q2 gauss meter : 0.8447
    Left Arm Q2 power supply current : 1605.2
    Left Arm Q2 momentum : 3.72783
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1357.54
    Left Arm D1 momentum : 3.72809
    Left Arm D1 NMR : 1.38101
    Left Arm Q3 gauss meter : -0.7407
    Left Arm Q3 power supply current : 1484.01
    Left Arm Q3 momentum : 3.72755
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.727159
    Right Arm Q1 power supply : 546.723
    Right Arm Q1 gauss meter : 0.013807
    Right Arm Q2 power supply current : 313.033
    Right Arm Q2 momentum : 0.727363
    Right Arm Q2 gauss meter : -0.16543
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 249.94
    Right Arm D1 momentum : 0.727201
    Right Arm D1 NMR : 0.269855
    Right Arm Q3 power supply current : 289.422
    Right Arm Q3 momentum : 0.727357
    Right Arm Q3 gauss meter : -0.13026
    Right Arm Q3 power supply polarity : enabled