User name a-onl
Log entry time 09:08:15 on April 30, 2007
Entry number 200613
keyword=End_of_Run_3016
****************************
Run Number: 3016
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=4.057
beam_raster=on
leftarm_p=3.728
leftarm_theta=21.55
leftarm_colli=out
rightarm_p=.7272
rightarm_theta=68.30
rightarm_colli=out
comment_text=100uA
PRESCALE FACTORS:ps1=500 ps2=20000 ps3=2 ps4=100 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1251862 [+]: 614966 [-]: 615551
TIME [0]: 26.748 mins [+]: 13.147 mins [-]: 13.146 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 2.07923 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 95.06%
TRIGGER RATES: PRES/REAL
T1[0] :26.2/13122.1 Hz T2[0] : 9.7/194626.1 Hz T3[0] :736.2/1472.4 Hz T4[0] : 9.6/959.7 Hz
T5[0] : 7.3/7.3 Hz T6[0] :62.3/62.3 Hz T7[0] : 4.0/4.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :26.2/13121.6 Hz T2[+] : 9.7/194586.8 Hz T3[+] :735.8/1471.7 Hz T4[+] : 9.6/960.6 Hz
T5[+] : 7.3/7.3 Hz T6[+] :62.2/62.2 Hz T7[+] : 4.0/4.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :26.2/13119.2 Hz T2[-] : 9.7/194595.1 Hz T3[-] :736.6/1473.1 Hz T4[-] : 9.6/958.5 Hz
T5[-] : 7.4/7.4 Hz T6[-] :62.3/62.3 Hz T7[-] :780.4/780.4 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 42119/21059518 T2[0] : 15617/312352860 T3[0] :1181557/2363114 T4[0] : 15401/1540154
T5[0] : 11780/11780 T6[0] : 99906/99906 T7[0] : 6448/6448 T8[0] : 25/1643404
T1[+] : 20701/10350579 T2[+] : 7674/153494385 T3[+] : 580446/1160892 T4[+] : 7577/757706
T5[+] : 5797/5797 T6[+] : 49061/49061 T7[+] : 3150/3150 T8[+] : 12/807754
T1[-] : 20695/10347712 T2[-] : 7674/153485736 T3[-] : 580950/1161901 T4[-] : 7560/756022
T5[-] : 5801/5801 T6[-] : 49129/49129 T7[-] : 615551/615551 T8[-] : 12/807674
AVERAGE CURRENT
BCM x1 : 88.6024uA BCM x3 : 88.4000uA BCM x10: -7.8155uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -59.77 ppm BCM u3 : -60.27 ppm BCM u10: -45.75 ppm
BCM d1 : -59.43 ppm BCM d3 : -60.29 ppm BCM d10: -48.73 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1427 BCM u3 [0]:0.1425 BCM u10[0]:-0.102
BCM u1 [+]:0.07013 BCM u3 [+]:0.07003 BCM u10[+]:0.04425
BCM u1 [-]:0.07014 BCM u3 [-]:0.07004 BCM u10[-]:0.04425
BCM d1 [0]:0.1417 BCM d3 [0]:0.1412 BCM d10[0]:0.07691
BCM d1 [+]:0.0696 BCM d3 [+]:0.06938 BCM d10[+]:0.03779
BCM d1 [-]:0.0696 BCM d3 [-]:0.06938 BCM d10[-]:0.03779
Right S1 scintillators
S1R [0]:9.803E+05 S1R [1]:8.291E+06 S1R [2]:6.782E+06
S1R [3]:4.772E+06 S1R [4]:1.591E+07 S1R [5]:3.053E+06
Right S1 scintillators rates
S1L [0]:668.5 Hz S1L [1]:17564.6 Hz S1L [2]:4099.1 Hz
S1L [3]:3141.7 Hz S1L [4]:2521.6 Hz S1L [5]:6179.3 Hz
Right S1 scintillators normalized by charge
S1L [0]:7515716.600000 S1L [1]:197484980.000000 S1L [2]:46088142.000000
S1L [3]:35322943.000000 S1L [4]:28350708.000000 S1L [5]:69476509.000000
S1R [0]:6867745.200000 S1R [1]:58084068.000000 S1R [2]:47514945.000000
S1R [3]:33428209.000000 S1R [4]:111490490.000000 S1R [5]:21390137.000000
Right arm S2 scintillators
S2 [0]:1.024E+07 S2 [1]:1.148E+07 S2 [2]:1.555E+07 S2 [3]:2.389E+07
S2 [4]:3.055E+07 S2 [5]:3.27E+07 S2 [6]:3.025E+07 S2 [7]:3.264E+07
S2 [8]:3.11E+07 S2 [9]:2.938E+07 S2 [10]:3.019E+07 S2 [11]:3.019E+07
S2 [12]:4.14E+07 S2 [13]:2.602E+07 S2 [14]:1.836E+07 S2 [15]:1.395E+07
S2 [16]:1.011E+07 S2 [17]:1.36E+07 S2 [18]:1.987E+07 S2 [19]:2.398E+07
S2 [20]:3.085E+07 S2 [21]:3.272E+07 S2 [22]:3.121E+07 S2 [23]:3.361E+07
S2 [24]:3.019E+07 S2 [25]:3.066E+07 S2 [26]:2.777E+07 S2 [27]:2.756E+07
S2 [28]:2.494E+07 S2 [29]:2.205E+07 S2 [30]:2.123E+07 S2 [31]:1.282E+07
Right arm S2 scintillators rates
S2 [0]:6383.2 Hz S2 [1]:7153.9 Hz S2 [2]:9687.5 Hz S2 [3]:14886.2 Hz
S2 [4]:19033.4 Hz S2 [5]:20372.3 Hz S2 [6]:18850.6 Hz S2 [7]:20339.0 Hz
S2 [8]:19376.9 Hz S2 [9]:18305.0 Hz S2 [10]:18808.4 Hz S2 [11]:18814.4 Hz
S2 [12]:25797.2 Hz S2 [13]:16210.7 Hz S2 [14]:11442.0 Hz S2 [15]:8692.6 Hz
S2 [16]:6298.8 Hz S2 [17]:8477.2 Hz S2 [18]:12379.3 Hz S2 [19]:14939.6 Hz
S2 [20]:19225.2 Hz S2 [21]:20390.2 Hz S2 [22]:19448.5 Hz S2 [23]:20943.8 Hz
S2 [24]:18811.4 Hz S2 [25]:19102.5 Hz S2 [26]:17303.7 Hz S2 [27]:17173.1 Hz
S2 [28]:15537.5 Hz S2 [29]:13739.0 Hz S2 [30]:13230.4 Hz S2 [31]:7986.6 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:71768228.000000 S2 [ 1]:80433643.000000 S2 [ 2]:108919510.000000
S2 [ 3]:167371080.000000 S2 [ 4]:213999710.000000 S2 [ 5]:229052580.000000
S2 [ 6]:211943590.000000 S2 [ 7]:228678190.000000 S2 [ 8]:217861540.000000
S2 [ 9]:205810120.000000 S2 [10]:211469400.000000 S2 [11]:211536710.000000
S2 [12]:290047220.000000 S2 [13]:182262600.000000 S2 [14]:128646800.000000
S2 [15]:97734454.000000 S2 [16]:70819649.000000 S2 [17]:95312107.000000
S2 [18]:139184650.000000 S2 [19]:167971570.000000 S2 [20]:216155280.000000
S2 [21]:229254810.000000 S2 [22]:218666990.000000 S2 [23]:235478290.000000
S2 [24]:211502990.000000 S2 [25]:214776660.000000 S2 [26]:194551970.000000
S2 [27]:193083570.000000 S2 [28]:174693170.000000 S2 [29]:154472210.000000
S2 [30]:148754260.000000 S2 [31]:89796042.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 55251217.000000
Right arm S2m : 175375300.000000
Left arm S1 scintillators
S1R [0]:7.871E+06 S1R [1]:1.081E+07 S1R [2]:1.647E+07
S1R [3]:1.345E+07 S1R [4]:1.619E+07 S1R [5]:9.897E+06
S1L [0]:7.201E+06 S1L [1]:8.942E+06 S1L [2]:1.354E+07
S1L [3]:1.414E+07 S1L [4]:1.545E+07 S1L [5]:1.043E+07
Left arm S1 scintillators rates
S1R [0]:4904.1 Hz S1R [1]:6735.8 Hz S1R [2]:10261.0 Hz
S1R [3]:8378.8 Hz S1R [4]:10088.8 Hz S1R [5]:6166.9 Hz
S1L [0]:4486.7 Hz S1L [1]:5571.4 Hz S1L [2]:8436.9 Hz
S1L [3]:8809.3 Hz S1L [4]:9624.8 Hz S1L [5]:6496.7 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:55138766.0 S1R [1]:75732593.0 S1R [2]:115368270.0
S1R [3]:94205717.0 S1R [4]:113432200.0 S1R [5]:69336171.0
S1L [0]:50445542.0 S1L [1]:62641620.0 S1L [2]:94859006.0
S1L [3]:99045669.0 S1L [4]:108215430.0 S1L [5]:73045171.0
Left arm S2 scintillators
S2R [0]:2.106E+07 S2R [1]:2.104E+07 S2R [2]:3.019E+07
S2R [3]:4.837E+07 S2R [4]:4.766E+07 S2R [5]:3.434E+07
S2L [0]:3.989E+07 S2L [1]:2.423E+07 S2L [2]:4.015E+07
S2L [3]:3.378E+07 S2L [4]:3.264E+07 S2L [5]:3.892E+07
Left arm S2 scintillators rates
S2R [0]:13120.7 Hz S2R [1]:13110.3 Hz S2R [2]:18809.9 Hz
S2R [3]:30137.5 Hz S2R [4]:29699.1 Hz S2R [5]:21395.1 Hz
S2L [0]:24857.0 Hz S2L [1]:15095.5 Hz S2L [2]:25016.0 Hz
S2L [3]:21049.3 Hz S2L [4]:20339.3 Hz S2L [5]:24251.0 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:147520920.0 S2R [1]:147403990.0 S2R [2]:211485920.0
S2R [3]:338846700.0 S2R [4]:333917480.0 S2R [5]:240552430.0
S2L [0]:279476230.0 S2L [1]:169724280.0 S2L [2]:281264370.0
S2L [3]:236665290.0 S2L [4]:228682540.0 S2L [5]:272663170.0
Left arm Gas Cerenkov
GasC [0]:1.836E+07 GasC [1]:1.389E+07 GasC [2]:1.579E+07
GasC [3]:1.554E+07 GasC [4]:1.669E+07 GasC [5]:1.541E+07
GasC [6]:1.522E+07 GasC [7]:1.531E+07 GasC [8]:1.32E+07
GasC [9]:3.28E+07
Left arm Gas Cerenkov rates
GasC [0]:11440.6 Hz GasC [1]:8655.0 Hz GasC [2]:9835.7 Hz
GasC [3]:9682.7 Hz GasC [4]:10400.9 Hz GasC [5]:9599.1 Hz
GasC [6]:9481.7 Hz GasC [7]:9541.0 Hz GasC [8]:8222.5 Hz
GasC [9]:20437.5 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:128630680.0 GasC [1]:97311261.0 GasC [2]:110586440.0
GasC [3]:108865890.0 GasC [4]:116941450.0 GasC [5]:107925940.0
GasC [6]:106606400.0 GasC [7]:107272370.0 GasC [8]:92448891.0
GasC [9]:229786100.0
Average of detectors sum of detectors charge normalized
Left S1 : 84288850.000000
Left S2 : 240683610.000000
Gas Cerenkov : 120637540.000000
****************************
End-of-run EPICS data for Run Number 3016 at Mon Apr 30 09:08:13 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.72809
Left Arm arm angle : 21.5458
Right Arm D1 momentum : 0.727199
Right Arm arm angle : 68.3281
HALLA:p : 4051.27
HALLA:dpp : 0
Tiefenbach Hall A energy : 4051.27
Left Arm Top VDC Current : 0.634766
Left Arm Bottom VDC Current : -1.75781
Left Arm Q1 momentum : 3.72808
Left Arm Q1 power supply : 2804.65
Left Arm Q1 gauss meter : -0.23636
Left Arm Q2 gauss meter : 0.8447
Left Arm Q2 power supply current : 1605.37
Left Arm Q2 momentum : 3.72822
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1357.54
Left Arm D1 momentum : 3.72809
Left Arm D1 NMR : 1.38101
Left Arm Q3 gauss meter : -0.7407
Left Arm Q3 power supply current : 1484
Left Arm Q3 momentum : 3.72753
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.727159
Right Arm Q1 power supply : 546.777
Right Arm Q1 gauss meter : 0.013811
Right Arm Q2 power supply current : 312.879
Right Arm Q2 momentum : 0.727004
Right Arm Q2 gauss meter : -0.16542
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 249.94
Right Arm D1 momentum : 0.727199
Right Arm D1 NMR : 0.269855
Right Arm Q3 power supply current : 289.363
Right Arm Q3 momentum : 0.727208
Right Arm Q3 gauss meter : -0.13025
Right Arm Q3 power supply polarity : enabled