Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 10:37:47 on April 30, 2007
Entry number 200621
keyword=End_of_Run_3020
****************************
Run Number: 3020
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=4.057
beam_raster=on
leftarm_p=3.728
leftarm_theta=21.55
leftarm_colli=out
rightarm_p=.7272
rightarm_theta=68.30
rightarm_colli=out
comment_text=100uA
PRESCALE FACTORS:ps1=500 ps2=20000 ps3=2 ps4=100 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1251587 [+]: 615613 [-]: 615351
TIME [0]: 31.093 mins [+]: 15.288 mins [-]: 15.285 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 1.84069 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 95.05%
TRIGGER RATES: PRES/REAL
T1[0] :22.7/11339.1 Hz T2[0] : 8.4/168701.6 Hz T3[0] :632.9/1265.9 Hz T4[0] : 8.2/822.3 Hz
T5[0] : 6.8/6.8 Hz T6[0] :53.8/53.8 Hz T7[0] : 3.3/3.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :22.7/11342.2 Hz T2[+] : 8.4/168712.3 Hz T3[+] :632.9/1265.7 Hz T4[+] : 8.2/822.8 Hz
T5[+] : 6.8/6.8 Hz T6[+] :54.0/54.0 Hz T7[+] : 3.3/3.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :22.7/11339.0 Hz T2[-] : 8.4/168703.3 Hz T3[-] :633.2/1266.5 Hz T4[-] : 8.2/822.4 Hz
T5[-] : 6.8/6.8 Hz T6[-] :53.7/53.7 Hz T7[-] :671.0/671.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 42307/21153762 T2[0] : 15736/314721573 T3[0] :1180793/2361587 T4[0] : 15340/1534038
T5[0] : 12652/12652 T6[0] : 100354/100354 T7[0] : 6183/6183 T8[0] : 29/1910325
T1[+] : 20807/10403635 T2[+] : 7737/154751671 T3[+] : 580490/1160981 T4[+] : 7546/754676
T5[+] : 6216/6216 T6[+] : 49512/49512 T7[+] : 3020/3020 T8[+] : 14/939266
T1[-] : 20798/10399136 T2[-] : 7735/154719387 T3[-] : 580745/1161490 T4[-] : 7542/754219
T5[-] : 6220/6220 T6[-] : 49286/49286 T7[-] : 615351/615351 T8[-] : 14/939120
AVERAGE CURRENT
BCM x1 : 76.5651uA BCM x3 : 76.3517uA BCM x10: 46.3662uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -101.8 ppm BCM u3 : -103.1 ppm BCM u10: -121.2 ppm
BCM d1 : -101.9 ppm BCM d3 : -105.5 ppm BCM d10: -120 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1433 BCM u3 [0]:0.1431 BCM u10[0]:0.09563
BCM u1 [+]:0.07044 BCM u3 [+]:0.07034 BCM u10[+]:0.04356
BCM u1 [-]:0.07045 BCM u3 [-]:0.07034 BCM u10[-]:0.04357
BCM d1 [0]:0.1424 BCM d3 [0]:0.1418 BCM d10[0]:0.07737
BCM d1 [+]:0.07 BCM d3 [+]:0.06971 BCM d10[+]:0.03802
BCM d1 [-]:0.07 BCM d3 [-]:0.06971 BCM d10[-]:0.03802
Right S1 scintillators
S1R [0]:9.86E+05 S1R [1]:8.315E+06 S1R [2]:6.833E+06
S1R [3]:4.798E+06 S1R [4]:1.604E+07 S1R [5]:3.059E+06
Right S1 scintillators rates
S1L [0]:578.1 Hz S1L [1]:15204.3 Hz S1L [2]:3542.6 Hz
S1L [3]:2717.1 Hz S1L [4]:2181.9 Hz S1L [5]:5316.0 Hz
Right S1 scintillators normalized by charge
S1L [0]:7526996.800000 S1L [1]:197953160.000000 S1L [2]:46123223.000000
S1L [3]:35374802.000000 S1L [4]:28407411.000000 S1L [5]:69211540.000000
S1R [0]:6881348.300000 S1R [1]:58028017.000000 S1R [2]:47688604.000000
S1R [3]:33485390.000000 S1R [4]:111936070.000000 S1R [5]:21349984.000000
Right arm S2 scintillators
S2 [0]:1.037E+07 S2 [1]:1.16E+07 S2 [2]:1.567E+07 S2 [3]:2.406E+07
S2 [4]:3.075E+07 S2 [5]:3.292E+07 S2 [6]:3.044E+07 S2 [7]:3.287E+07
S2 [8]:3.133E+07 S2 [9]:2.959E+07 S2 [10]:3.041E+07 S2 [11]:3.041E+07
S2 [12]:4.171E+07 S2 [13]:2.623E+07 S2 [14]:1.851E+07 S2 [15]:1.408E+07
S2 [16]:1.024E+07 S2 [17]:1.375E+07 S2 [18]:2.005E+07 S2 [19]:2.416E+07
S2 [20]:3.107E+07 S2 [21]:3.295E+07 S2 [22]:3.142E+07 S2 [23]:3.401E+07
S2 [24]:3.041E+07 S2 [25]:3.088E+07 S2 [26]:2.797E+07 S2 [27]:2.777E+07
S2 [28]:2.511E+07 S2 [29]:2.222E+07 S2 [30]:2.141E+07 S2 [31]:1.293E+07
Right arm S2 scintillators rates
S2 [0]:5561.3 Hz S2 [1]:6216.2 Hz S2 [2]:8401.2 Hz S2 [3]:12899.0 Hz
S2 [4]:16484.7 Hz S2 [5]:17646.5 Hz S2 [6]:16316.8 Hz S2 [7]:17617.2 Hz
S2 [8]:16792.3 Hz S2 [9]:15862.7 Hz S2 [10]:16299.5 Hz S2 [11]:16300.4 Hz
S2 [12]:22357.8 Hz S2 [13]:14059.7 Hz S2 [14]:9920.7 Hz S2 [15]:7546.2 Hz
S2 [16]:5489.9 Hz S2 [17]:7371.5 Hz S2 [18]:10747.6 Hz S2 [19]:12948.5 Hz
S2 [20]:16655.5 Hz S2 [21]:17662.4 Hz S2 [22]:16842.8 Hz S2 [23]:18232.4 Hz
S2 [24]:16303.3 Hz S2 [25]:16555.2 Hz S2 [26]:14994.2 Hz S2 [27]:14885.3 Hz
S2 [28]:13461.2 Hz S2 [29]:11909.5 Hz S2 [30]:11476.1 Hz S2 [31]:6930.1 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:72405404.000000 S2 [ 1]:80931860.000000 S2 [ 2]:109379890.000000
S2 [ 3]:167938860.000000 S2 [ 4]:214623880.000000 S2 [ 5]:229749440.000000
S2 [ 6]:212437740.000000 S2 [ 7]:229367620.000000 S2 [ 8]:218628190.000000
S2 [ 9]:206525210.000000 S2 [10]:212212170.000000 S2 [11]:212223770.000000
S2 [12]:291088500.000000 S2 [13]:183050750.000000 S2 [14]:129163030.000000
S2 [15]:98248568.000000 S2 [16]:71475922.000000 S2 [17]:95973961.000000
S2 [18]:139929030.000000 S2 [19]:168583020.000000 S2 [20]:216847500.000000
S2 [21]:229956120.000000 S2 [22]:219285220.000000 S2 [23]:237377540.000000
S2 [24]:212261880.000000 S2 [25]:215541630.000000 S2 [26]:195217470.000000
S2 [27]:193799560.000000 S2 [28]:175258890.000000 S2 [29]:155056100.000000
S2 [30]:149413650.000000 S2 [31]:90227401.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 55330546.000000
Right arm S2m : 176068120.000000
Left arm S1 scintillators
S1R [0]:7.974E+06 S1R [1]:1.091E+07 S1R [2]:1.658E+07
S1R [3]:1.355E+07 S1R [4]:1.626E+07 S1R [5]:9.963E+06
S1L [0]:7.297E+06 S1L [1]:9.035E+06 S1L [2]:1.366E+07
S1L [3]:1.426E+07 S1L [4]:1.555E+07 S1L [5]:1.051E+07
Left arm S1 scintillators rates
S1R [0]:4274.5 Hz S1R [1]:5847.3 Hz S1R [2]:8887.2 Hz
S1R [3]:7261.0 Hz S1R [4]:8713.8 Hz S1R [5]:5340.5 Hz
S1L [0]:3911.3 Hz S1L [1]:4843.1 Hz S1L [2]:7324.1 Hz
S1L [3]:7643.4 Hz S1L [4]:8334.3 Hz S1L [5]:5635.7 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:55652097.0 S1R [1]:76129688.0 S1R [2]:115707330.0
S1R [3]:94535430.0 S1R [4]:113449810.0 S1R [5]:69531475.0
S1L [0]:50922785.0 S1L [1]:63055504.0 S1L [2]:95356396.0
S1L [3]:99513227.0 S1L [4]:108508390.0 S1L [5]:73374086.0
Left arm S2 scintillators
S2R [0]:2.125E+07 S2R [1]:2.127E+07 S2R [2]:3.044E+07
S2R [3]:4.872E+07 S2R [4]:4.806E+07 S2R [5]:3.467E+07
S2L [0]:4.034E+07 S2L [1]:2.442E+07 S2L [2]:4.043E+07
S2L [3]:3.403E+07 S2L [4]:3.29E+07 S2L [5]:3.923E+07
Left arm S2 scintillators rates
S2R [0]:11391.3 Hz S2R [1]:11400.6 Hz S2R [2]:16317.1 Hz
S2R [3]:26114.4 Hz S2R [4]:25764.0 Hz S2R [5]:18582.9 Hz
S2L [0]:21622.9 Hz S2L [1]:13089.7 Hz S2L [2]:21671.3 Hz
S2L [3]:18240.2 Hz S2L [4]:17634.8 Hz S2L [5]:21026.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:148310010.0 S2R [1]:148430560.0 S2R [2]:212441060.0
S2R [3]:339997170.0 S2R [4]:335435450.0 S2R [5]:241940850.0
S2L [0]:281519910.0 S2L [1]:170421800.0 S2L [2]:282150130.0
S2L [3]:237479280.0 S2L [4]:229596530.0 S2L [5]:273749820.0
Left arm Gas Cerenkov
GasC [0]:1.886E+07 GasC [1]:1.423E+07 GasC [2]:1.615E+07
GasC [3]:1.595E+07 GasC [4]:1.717E+07 GasC [5]:1.582E+07
GasC [6]:1.563E+07 GasC [7]:1.576E+07 GasC [8]:1.358E+07
GasC [9]:3.594E+07
Left arm Gas Cerenkov rates
GasC [0]:10108.1 Hz GasC [1]:7628.1 Hz GasC [2]:8658.1 Hz
GasC [3]:8551.8 Hz GasC [4]:9205.6 Hz GasC [5]:8482.5 Hz
GasC [6]:8378.6 Hz GasC [7]:8446.2 Hz GasC [8]:7277.0 Hz
GasC [9]:19262.8 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:131603400.0 GasC [1]:99314858.0 GasC [2]:112724330.0
GasC [3]:111340560.0 GasC [4]:119852890.0 GasC [5]:110438270.0
GasC [6]:109085890.0 GasC [7]:109966110.0 GasC [8]:94742865.0
GasC [9]:250793330.0
Average of detectors sum of detectors charge normalized
Left S1 : 84644683.000000
Left S2 : 241789380.000000
Gas Cerenkov : 124986250.000000
****************************
End-of-run EPICS data for Run Number 3020 at Mon Apr 30 10:37:45 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.72808
Left Arm arm angle : 21.5458
Right Arm D1 momentum : 0.727197
Right Arm arm angle : 68.3281
HALLA:p : 4051.27
HALLA:dpp : 0
Tiefenbach Hall A energy : 4051.27
Left Arm Top VDC Current : 2.29492
Left Arm Bottom VDC Current : -1.95312
Left Arm Q1 momentum : 3.72808
Left Arm Q1 power supply : 2804.75
Left Arm Q1 gauss meter : -0.23634
Left Arm Q2 gauss meter : 0.8448
Left Arm Q2 power supply current : 1605.34
Left Arm Q2 momentum : 3.72815
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1357.55
Left Arm D1 momentum : 3.72808
Left Arm D1 NMR : 1.381
Left Arm Q3 gauss meter : -0.7406
Left Arm Q3 power supply current : 1484.14
Left Arm Q3 momentum : 3.72788
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.727088
Right Arm Q1 power supply : 546.723
Right Arm Q1 gauss meter : 0.013801
Right Arm Q2 power supply current : 312.965
Right Arm Q2 momentum : 0.727204
Right Arm Q2 gauss meter : -0.16541
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 249.932
Right Arm D1 momentum : 0.727197
Right Arm D1 NMR : 0.269854
Right Arm Q3 power supply current : 289.321
Right Arm Q3 momentum : 0.727104
Right Arm Q3 gauss meter : -0.13026
Right Arm Q3 power supply polarity : enabled