keyword=End_of_Run_3025
****************************
Run Number: 3025
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=4.057
beam_raster=on
leftarm_p=3.728
leftarm_theta=21.55
leftarm_colli=out
rightarm_p=.7272
rightarm_theta=68.30
rightarm_colli=out
comment_text=100uA
PRESCALE FACTORS:ps1=500 ps2=20000 ps3=2 ps4=100 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1250526 [+]: 612630 [-]: 613390
TIME [0]: 26.455 mins [+]: 12.973 mins [-]: 12.973 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 5.58644 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 95.12%
TRIGGER RATES: PRES/REAL
T1[0] :27.3/13642.4 Hz T2[0] :10.0/199624.6 Hz T3[0] :742.3/1484.5 Hz T4[0] : 9.6/963.0 Hz
T5[0] : 7.4/7.4 Hz T6[0] :62.9/62.9 Hz T7[0] : 4.0/4.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :27.3/13641.1 Hz T2[+] :10.0/199571.2 Hz T3[+] :741.6/1483.3 Hz T4[+] : 9.6/962.8 Hz
T5[+] : 7.3/7.3 Hz T6[+] :62.7/62.7 Hz T7[+] : 4.0/4.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :27.3/13636.2 Hz T2[-] :10.0/199576.6 Hz T3[-] :742.4/1484.7 Hz T4[-] : 9.6/962.3 Hz
T5[-] : 7.5/7.5 Hz T6[-] :63.1/63.1 Hz T7[-] :788.0/788.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 43308/21654457 T2[0] : 15843/316861792 T3[0] :1178178/2356356 T4[0] : 15285/1528516
T5[0] : 11730/11730 T6[0] : 99839/99839 T7[0] : 6331/6331 T8[0] : 24/1625383
T1[+] : 21236/10618056 T2[+] : 7767/155343740 T3[+] : 577272/1154545 T4[+] : 7494/749451
T5[+] : 5712/5712 T6[+] : 48778/48778 T7[+] : 3133/3133 T8[+] : 12/797069
T1[-] : 21228/10614458 T2[-] : 7767/155351511 T3[-] : 577850/1155701 T4[-] : 7490/749086
T5[-] : 5801/5801 T6[-] : 49106/49106 T7[-] : 613390/613390 T8[-] : 12/797087
AVERAGE CURRENT
BCM x1 : 91.7159uA BCM x3 : 91.4628uA BCM x10: 50.7300uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 6.458 ppm BCM u3 : 6.62 ppm BCM u10: -10.15 ppm
BCM d1 : 6.971 ppm BCM d3 : 7.307 ppm BCM d10: 10.2 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.146 BCM u3 [0]:0.1458 BCM u10[0]:0.08342
BCM u1 [+]:0.07159 BCM u3 [+]:0.07149 BCM u10[+]:0.04067
BCM u1 [-]:0.07159 BCM u3 [-]:0.07149 BCM u10[-]:0.04067
BCM d1 [0]:0.1451 BCM d3 [0]:0.1445 BCM d10[0]:0.07763
BCM d1 [+]:0.07113 BCM d3 [+]:0.07084 BCM d10[+]:0.03806
BCM d1 [-]:0.07113 BCM d3 [-]:0.07084 BCM d10[-]:0.03806
Right S1 scintillators
S1R [0]:9.864E+05 S1R [1]:8.651E+06 S1R [2]:6.831E+06
S1R [3]:4.868E+06 S1R [4]:1.632E+07 S1R [5]:3.155E+06
Right S1 scintillators rates
S1L [0]:699.2 Hz S1L [1]:17769.0 Hz S1L [2]:4272.9 Hz
S1L [3]:3269.0 Hz S1L [4]:2602.6 Hz S1L [5]:6475.4 Hz
Right S1 scintillators normalized by charge
S1L [0]:7599012.200000 S1L [1]:193116410.000000 S1L [2]:46438286.000000
S1L [3]:35528057.000000 S1L [4]:28285582.000000 S1L [5]:70375709.000000
S1R [0]:6753820.100000 S1R [1]:59232717.000000 S1R [2]:46770037.000000
S1R [3]:33329154.000000 S1R [4]:111716910.000000 S1R [5]:21601183.000000
Right arm S2 scintillators
S2 [0]:1.027E+07 S2 [1]:1.157E+07 S2 [2]:1.577E+07 S2 [3]:2.424E+07
S2 [4]:3.112E+07 S2 [5]:3.335E+07 S2 [6]:3.08E+07 S2 [7]:3.328E+07
S2 [8]:3.167E+07 S2 [9]:2.99E+07 S2 [10]:3.07E+07 S2 [11]:3.083E+07
S2 [12]:4.225E+07 S2 [13]:2.64E+07 S2 [14]:1.86E+07 S2 [15]:1.408E+07
S2 [16]:1.012E+07 S2 [17]:1.37E+07 S2 [18]:2.009E+07 S2 [19]:2.431E+07
S2 [20]:3.139E+07 S2 [21]:3.327E+07 S2 [22]:3.171E+07 S2 [23]:3.458E+07
S2 [24]:3.072E+07 S2 [25]:3.116E+07 S2 [26]:2.823E+07 S2 [27]:2.799E+07
S2 [28]:2.536E+07 S2 [29]:2.237E+07 S2 [30]:2.156E+07 S2 [31]:1.297E+07
Right arm S2 scintillators rates
S2 [0]:6470.7 Hz S2 [1]:7290.9 Hz S2 [2]:9933.1 Hz S2 [3]:15271.2 Hz
S2 [4]:19608.4 Hz S2 [5]:21010.9 Hz S2 [6]:19401.1 Hz S2 [7]:20965.3 Hz
S2 [8]:19951.9 Hz S2 [9]:18839.4 Hz S2 [10]:19342.9 Hz S2 [11]:19420.2 Hz
S2 [12]:26619.9 Hz S2 [13]:16631.2 Hz S2 [14]:11720.4 Hz S2 [15]:8872.7 Hz
S2 [16]:6378.2 Hz S2 [17]:8633.0 Hz S2 [18]:12656.0 Hz S2 [19]:15313.6 Hz
S2 [20]:19777.8 Hz S2 [21]:20960.1 Hz S2 [22]:19978.7 Hz S2 [23]:21783.0 Hz
S2 [24]:19351.8 Hz S2 [25]:19632.3 Hz S2 [26]:17782.1 Hz S2 [27]:17634.8 Hz
S2 [28]:15976.5 Hz S2 [29]:14094.0 Hz S2 [30]:13584.5 Hz S2 [31]:8170.1 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:70324781.000000 S2 [ 1]:79238922.000000 S2 [ 2]:107953880.000000
S2 [ 3]:165969590.000000 S2 [ 4]:213106340.000000 S2 [ 5]:228349830.000000
S2 [ 6]:210853540.000000 S2 [ 7]:227853410.000000 S2 [ 8]:216839820.000000
S2 [ 9]:204749170.000000 S2 [10]:210221050.000000 S2 [11]:211061180.000000
S2 [12]:289308820.000000 S2 [13]:180750130.000000 S2 [14]:127379460.000000
S2 [15]:96429365.000000 S2 [16]:69319568.000000 S2 [17]:93824497.000000
S2 [18]:137547280.000000 S2 [19]:166430260.000000 S2 [20]:214948040.000000
S2 [21]:227797340.000000 S2 [22]:217131670.000000 S2 [23]:236740600.000000
S2 [24]:210318470.000000 S2 [25]:213366930.000000 S2 [26]:193258530.000000
S2 [27]:191658000.000000 S2 [28]:173634810.000000 S2 [29]:153175910.000000
S2 [30]:147637850.000000 S2 [31]:88794050.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 55062240.000000
Right arm S2m : 174249160.000000
Left arm S1 scintillators
S1R [0]:7.635E+06 S1R [1]:1.057E+07 S1R [2]:1.631E+07
S1R [3]:1.346E+07 S1R [4]:1.601E+07 S1R [5]:9.82E+06
S1L [0]:6.991E+06 S1L [1]:8.809E+06 S1L [2]:1.349E+07
S1L [3]:1.415E+07 S1L [4]:1.547E+07 S1L [5]:1.041E+07
Left arm S1 scintillators rates
S1R [0]:4810.0 Hz S1R [1]:6661.1 Hz S1R [2]:10274.3 Hz
S1R [3]:8478.9 Hz S1R [4]:10086.7 Hz S1R [5]:6186.6 Hz
S1L [0]:4404.2 Hz S1L [1]:5549.5 Hz S1L [2]:8499.1 Hz
S1L [3]:8915.0 Hz S1L [4]:9748.3 Hz S1L [5]:6558.7 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:52275706.0 S1R [1]:72393681.0 S1R [2]:111662320.0
S1R [3]:92150381.0 S1R [4]:109623630.0 S1R [5]:67237201.0
S1L [0]:47865979.0 S1L [1]:60312624.0 S1L [2]:92369005.0
S1L [3]:96889489.0 S1L [4]:105945920.0 S1L [5]:71280395.0
Left arm S2 scintillators
S2R [0]:2.064E+07 S2R [1]:2.07E+07 S2R [2]:3.026E+07
S2R [3]:4.752E+07 S2R [4]:4.793E+07 S2R [5]:3.41E+07
S2L [0]:3.972E+07 S2L [1]:2.401E+07 S2L [2]:3.997E+07
S2L [3]:3.308E+07 S2L [4]:3.269E+07 S2L [5]:3.88E+07
Left arm S2 scintillators rates
S2R [0]:13004.1 Hz S2R [1]:13039.9 Hz S2R [2]:19065.3 Hz
S2R [3]:29935.6 Hz S2R [4]:30198.9 Hz S2R [5]:21483.2 Hz
S2L [0]:25022.0 Hz S2L [1]:15126.6 Hz S2L [2]:25178.8 Hz
S2L [3]:20843.1 Hz S2L [4]:20595.7 Hz S2L [5]:24446.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:141330630.0 S2R [1]:141719320.0 S2R [2]:207204800.0
S2R [3]:325344570.0 S2R [4]:328206260.0 S2R [5]:233481990.0
S2L [0]:271942180.0 S2L [1]:164397970.0 S2L [2]:273646730.0
S2L [3]:226525990.0 S2L [4]:223837310.0 S2L [5]:265683870.0
Left arm Gas Cerenkov
GasC [0]:1.86E+07 GasC [1]:1.409E+07 GasC [2]:1.599E+07
GasC [3]:1.577E+07 GasC [4]:1.693E+07 GasC [5]:1.562E+07
GasC [6]:1.541E+07 GasC [7]:1.555E+07 GasC [8]:1.337E+07
GasC [9]:3.296E+07
Left arm Gas Cerenkov rates
GasC [0]:11720.9 Hz GasC [1]:8873.9 Hz GasC [2]:10071.8 Hz
GasC [3]:9935.0 Hz GasC [4]:10666.2 Hz GasC [5]:9842.0 Hz
GasC [6]:9708.8 Hz GasC [7]:9794.5 Hz GasC [8]:8423.1 Hz
GasC [9]:20765.4 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:127384290.0 GasC [1]:96443264.0 GasC [2]:109461430.0
GasC [3]:107974660.0 GasC [4]:115921560.0 GasC [5]:106964770.0
GasC [6]:105516210.0 GasC [7]:106447530.0 GasC [8]:91542985.0
GasC [9]:225681400.0
Average of detectors sum of detectors charge normalized
Left S1 : 81667195.000000
Left S2 : 233610150.000000
Gas Cerenkov : 119333810.000000
****************************
End-of-run EPICS data for Run Number 3025 at Mon Apr 30 17:16:20 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.728
Left Arm arm angle : 21.5458
Right Arm D1 momentum : 0.727197
Right Arm arm angle : 68.3281
HALLA:p : 4051.27
HALLA:dpp : 0
Tiefenbach Hall A energy : 4051.27
Left Arm Top VDC Current : 3.32031
Left Arm Bottom VDC Current : 2.88086
Left Arm Q1 momentum : 3.72794
Left Arm Q1 power supply : 2804.59
Left Arm Q1 gauss meter : -0.23634
Left Arm Q2 gauss meter : 0.8445
Left Arm Q2 power supply current : 1605.15
Left Arm Q2 momentum : 3.7277
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1357.54
Left Arm D1 momentum : 3.728
Left Arm D1 NMR : 1.38097
Left Arm Q3 gauss meter : -0.7408
Left Arm Q3 power supply current : 1484.13
Left Arm Q3 momentum : 3.72785
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.727302
Right Arm Q1 power supply : 546.883
Right Arm Q1 gauss meter : 0.013795
Right Arm Q2 power supply current : 313.052
Right Arm Q2 momentum : 0.727406
Right Arm Q2 gauss meter : -0.16543
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 249.971
Right Arm D1 momentum : 0.727197
Right Arm D1 NMR : 0.269854
Right Arm Q3 power supply current : 289.242
Right Arm Q3 momentum : 0.726905
Right Arm Q3 gauss meter : -0.13028
Right Arm Q3 power supply polarity : enabled