User name a-onl
Log entry time 17:48:08 on April 30, 2007
Entry number 200646
keyword=End_of_Run_3026
****************************
Run Number: 3026
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=4.057
beam_raster=on
leftarm_p=3.728
leftarm_theta=21.55
leftarm_colli=out
rightarm_p=.7272
rightarm_theta=68.30
rightarm_colli=out
comment_text=100uA
PRESCALE FACTORS:ps1=500 ps2=20000 ps3=2 ps4=100 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1252821 [+]: 615300 [-]: 616029
TIME [0]: 30.744 mins [+]: 15.115 mins [-]: 15.115 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 1.86933 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 95.18%
TRIGGER RATES: PRES/REAL
T1[0] :23.4/11685.9 Hz T2[0] : 8.6/172367.5 Hz T3[0] :639.7/1279.4 Hz T4[0] : 8.3/829.1 Hz
T5[0] : 6.7/6.7 Hz T6[0] :53.6/53.6 Hz T7[0] : 3.4/3.4 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :23.4/11678.6 Hz T2[+] : 8.6/172283.8 Hz T3[+] :639.0/1278.1 Hz T4[+] : 8.3/829.6 Hz
T5[+] : 6.8/6.8 Hz T6[+] :53.5/53.5 Hz T7[+] : 3.3/3.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :23.4/11682.7 Hz T2[-] : 8.6/172307.8 Hz T3[-] :639.9/1279.9 Hz T4[-] : 8.3/827.8 Hz
T5[-] : 6.7/6.7 Hz T6[-] :53.7/53.7 Hz T7[-] :679.3/679.3 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 43112/21556382 T2[0] : 15897/317958737 T3[0] :1180043/2360086 T4[0] : 15293/1529380
T5[0] : 12448/12448 T6[0] : 98890/98890 T7[0] : 6263/6263 T8[0] : 28/1888928
T1[+] : 21182/10591060 T2[+] : 7812/156240403 T3[+] : 579531/1159062 T4[+] : 7523/752312
T5[+] : 6150/6150 T6[+] : 48508/48508 T7[+] : 3034/3034 T8[+] : 14/928643
T1[-] : 21189/10594898 T2[-] : 7813/156263984 T3[-] : 580352/1160705 T4[-] : 7506/750684
T5[-] : 6085/6085 T6[-] : 48686/48686 T7[-] : 616029/616029 T8[-] : 14/928654
AVERAGE CURRENT
BCM x1 : 78.6016uA BCM x3 : 78.3937uA BCM x10: 44.4712uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 9.213 ppm BCM u3 : 8.939 ppm BCM u10: 6.286 ppm
BCM d1 : 10.34 ppm BCM d3 : 8.525 ppm BCM d10: 6.343 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1454 BCM u3 [0]:0.1452 BCM u10[0]:0.08479
BCM u1 [+]:0.07147 BCM u3 [+]:0.07137 BCM u10[+]:0.04141
BCM u1 [-]:0.07147 BCM u3 [-]:0.07137 BCM u10[-]:0.04141
BCM d1 [0]:0.1445 BCM d3 [0]:0.144 BCM d10[0]:0.07928
BCM d1 [+]:0.07102 BCM d3 [+]:0.07074 BCM d10[+]:0.03896
BCM d1 [-]:0.07102 BCM d3 [-]:0.07074 BCM d10[-]:0.03896
Right S1 scintillators
S1R [0]:9.959E+05 S1R [1]:8.537E+06 S1R [2]:6.839E+06
S1R [3]:4.864E+06 S1R [4]:1.62E+07 S1R [5]:3.138E+06
Right S1 scintillators rates
S1L [0]:596.8 Hz S1L [1]:15450.6 Hz S1L [2]:3651.0 Hz
S1L [3]:2797.0 Hz S1L [4]:2240.1 Hz S1L [5]:5504.3 Hz
Right S1 scintillators normalized by charge
S1L [0]:7569275.900000 S1L [1]:195954240.000000 S1L [2]:46303693.000000
S1L [3]:35473348.000000 S1L [4]:28409773.000000 S1L [5]:69808872.000000
S1R [0]:6847325.800000 S1R [1]:58692013.000000 S1R [2]:47021394.000000
S1R [3]:33439525.000000 S1R [4]:111404000.000000 S1R [5]:21576892.000000
Right arm S2 scintillators
S2 [0]:1.034E+07 S2 [1]:1.163E+07 S2 [2]:1.579E+07 S2 [3]:2.43E+07
S2 [4]:3.115E+07 S2 [5]:3.337E+07 S2 [6]:3.084E+07 S2 [7]:3.332E+07
S2 [8]:3.173E+07 S2 [9]:2.995E+07 S2 [10]:3.077E+07 S2 [11]:3.085E+07
S2 [12]:4.23E+07 S2 [13]:2.649E+07 S2 [14]:1.867E+07 S2 [15]:1.415E+07
S2 [16]:1.019E+07 S2 [17]:1.38E+07 S2 [18]:2.019E+07 S2 [19]:2.438E+07
S2 [20]:3.143E+07 S2 [21]:3.334E+07 S2 [22]:3.18E+07 S2 [23]:3.468E+07
S2 [24]:3.079E+07 S2 [25]:3.123E+07 S2 [26]:2.829E+07 S2 [27]:2.806E+07
S2 [28]:2.541E+07 S2 [29]:2.244E+07 S2 [30]:2.163E+07 S2 [31]:1.302E+07
Right arm S2 scintillators rates
S2 [0]:5606.7 Hz S2 [1]:6307.0 Hz S2 [2]:8562.3 Hz S2 [3]:13173.3 Hz
S2 [4]:16884.1 Hz S2 [5]:18092.3 Hz S2 [6]:16719.5 Hz S2 [7]:18061.8 Hz
S2 [8]:17198.5 Hz S2 [9]:16236.9 Hz S2 [10]:16680.6 Hz S2 [11]:16725.2 Hz
S2 [12]:22930.8 Hz S2 [13]:14363.1 Hz S2 [14]:10121.9 Hz S2 [15]:7672.9 Hz
S2 [16]:5525.1 Hz S2 [17]:7479.4 Hz S2 [18]:10942.9 Hz S2 [19]:13218.4 Hz
S2 [20]:17040.9 Hz S2 [21]:18075.8 Hz S2 [22]:17238.1 Hz S2 [23]:18799.1 Hz
S2 [24]:16689.9 Hz S2 [25]:16932.0 Hz S2 [26]:15334.6 Hz S2 [27]:15210.4 Hz
S2 [28]:13772.6 Hz S2 [29]:12163.1 Hz S2 [30]:11727.8 Hz S2 [31]:7056.2 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:71107352.000000 S2 [ 1]:79988818.000000 S2 [ 2]:108592630.000000
S2 [ 3]:167072120.000000 S2 [ 4]:214134340.000000 S2 [ 5]:229457070.000000
S2 [ 6]:212047380.000000 S2 [ 7]:229070250.000000 S2 [ 8]:218121990.000000
S2 [ 9]:205926380.000000 S2 [10]:211553990.000000 S2 [11]:212119270.000000
S2 [12]:290822580.000000 S2 [13]:182161560.000000 S2 [14]:128371910.000000
S2 [15]:97312856.000000 S2 [16]:70072286.000000 S2 [17]:94858490.000000
S2 [18]:138785040.000000 S2 [19]:167643960.000000 S2 [20]:216123440.000000
S2 [21]:229248480.000000 S2 [22]:218623870.000000 S2 [23]:238421510.000000
S2 [24]:211671970.000000 S2 [25]:214741370.000000 S2 [26]:194482850.000000
S2 [27]:192907280.000000 S2 [28]:174672170.000000 S2 [29]:154259630.000000
S2 [30]:148739670.000000 S2 [31]:89490857.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 55208362.000000
Right arm S2m : 175393870.000000
Left arm S1 scintillators
S1R [0]:7.896E+06 S1R [1]:1.083E+07 S1R [2]:1.659E+07
S1R [3]:1.364E+07 S1R [4]:1.62E+07 S1R [5]:9.976E+06
S1L [0]:7.226E+06 S1L [1]:9.019E+06 S1L [2]:1.368E+07
S1L [3]:1.434E+07 S1L [4]:1.563E+07 S1L [5]:1.055E+07
Left arm S1 scintillators rates
S1R [0]:4280.4 Hz S1R [1]:5870.4 Hz S1R [2]:8991.6 Hz
S1R [3]:7394.9 Hz S1R [4]:8784.6 Hz S1R [5]:5408.1 Hz
S1L [0]:3917.1 Hz S1L [1]:4889.1 Hz S1L [2]:7417.4 Hz
S1L [3]:7772.8 Hz S1L [4]:8472.3 Hz S1L [5]:5718.0 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:54286863.0 S1R [1]:74452568.0 S1R [2]:114036790.0
S1R [3]:93786166.0 S1R [4]:111411060.0 S1R [5]:68588166.0
S1L [0]:49679593.0 S1L [1]:62006000.0 S1L [2]:94072537.0
S1L [3]:98579943.0 S1L [4]:107451340.0 S1L [5]:72519757.0
Left arm S2 scintillators
S2R [0]:2.112E+07 S2R [1]:2.113E+07 S2R [2]:3.061E+07
S2R [3]:4.9E+07 S2R [4]:4.838E+07 S2R [5]:3.462E+07
S2L [0]:4.037E+07 S2L [1]:2.441E+07 S2L [2]:4.045E+07
S2L [3]:3.361E+07 S2L [4]:3.312E+07 S2L [5]:3.918E+07
Left arm S2 scintillators rates
S2R [0]:11449.0 Hz S2R [1]:11455.2 Hz S2R [2]:16593.9 Hz
S2R [3]:26565.4 Hz S2R [4]:26224.8 Hz S2R [5]:18767.7 Hz
S2L [0]:21883.5 Hz S2L [1]:13233.7 Hz S2L [2]:21929.7 Hz
S2L [3]:18220.4 Hz S2L [4]:17955.2 Hz S2L [5]:21239.4 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:145203440.0 S2R [1]:145281920.0 S2R [2]:210454320.0
S2R [3]:336918280.0 S2R [4]:332598180.0 S2R [5]:238022820.0
S2L [0]:277540420.0 S2L [1]:167838240.0 S2L [2]:278125260.0
S2L [3]:231082440.0 S2L [4]:227718470.0 S2L [5]:269370800.0
Left arm Gas Cerenkov
GasC [0]:1.9E+07 GasC [1]:1.435E+07 GasC [2]:1.629E+07
GasC [3]:1.609E+07 GasC [4]:1.731E+07 GasC [5]:1.594E+07
GasC [6]:1.576E+07 GasC [7]:1.59E+07 GasC [8]:1.369E+07
GasC [9]:4.173E+07
Left arm Gas Cerenkov rates
GasC [0]:10299.6 Hz GasC [1]:7778.2 Hz GasC [2]:8828.6 Hz
GasC [3]:8721.7 Hz GasC [4]:9382.8 Hz GasC [5]:8643.4 Hz
GasC [6]:8544.7 Hz GasC [7]:8621.0 Hz GasC [8]:7420.4 Hz
GasC [9]:22621.4 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:130625700.0 GasC [1]:98648105.0 GasC [2]:111969640.0
GasC [3]:110614420.0 GasC [4]:118998330.0 GasC [5]:109620230.0
GasC [6]:108369530.0 GasC [7]:109336450.0 GasC [8]:94110544.0
GasC [9]:286898290.0
Average of detectors sum of detectors charge normalized
Left S1 : 83405900.000000
Left S2 : 238346210.000000
Gas Cerenkov : 127919120.000000
****************************
End-of-run EPICS data for Run Number 3026 at Mon Apr 30 17:48:06 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.72799
Left Arm arm angle : 21.5458
Right Arm D1 momentum : 0.7272
Right Arm arm angle : 68.3281
HALLA:p : 4051.27
HALLA:dpp : 0
Tiefenbach Hall A energy : 4051.27
Left Arm Top VDC Current : 3.41797
Left Arm Bottom VDC Current : 0.0488281
Left Arm Q1 momentum : 3.72787
Left Arm Q1 power supply : 2804.59
Left Arm Q1 gauss meter : -0.23635
Left Arm Q2 gauss meter : 0.8443
Left Arm Q2 power supply current : 1604.96
Left Arm Q2 momentum : 3.72726
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1357.54
Left Arm D1 momentum : 3.72799
Left Arm D1 NMR : 1.38097
Left Arm Q3 gauss meter : -0.7408
Left Arm Q3 power supply current : 1484.23
Left Arm Q3 momentum : 3.72811
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.727302
Right Arm Q1 power supply : 546.937
Right Arm Q1 gauss meter : 0.013798
Right Arm Q2 power supply current : 313.057
Right Arm Q2 momentum : 0.727417
Right Arm Q2 gauss meter : -0.16545
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 249.978
Right Arm D1 momentum : 0.7272
Right Arm D1 NMR : 0.269855
Right Arm Q3 power supply current : 289.364
Right Arm Q3 momentum : 0.727211
Right Arm Q3 gauss meter : -0.13025
Right Arm Q3 power supply polarity : enabled