Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 20:12:53 on April 30, 2007
Entry number 200658
keyword=End_of_Run_3031
****************************
Run Number: 3031
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=4.057
beam_raster=on
leftarm_p=3.728
leftarm_theta=21.55
leftarm_colli=out
rightarm_p=.7272
rightarm_theta=68.30
rightarm_colli=out
comment_text=100uA
PRESCALE FACTORS:ps1=500 ps2=20000 ps3=2 ps4=100 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1252776 [+]: 615433 [-]: 615706
TIME [0]: 26.528 mins [+]: 13.037 mins [-]: 13.038 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 2.12674 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 95.01%
TRIGGER RATES: PRES/REAL
T1[0] :26.7/13336.9 Hz T2[0] : 9.8/196945.8 Hz T3[0] :743.2/1486.4 Hz T4[0] : 9.7/966.2 Hz
T5[0] : 7.3/7.3 Hz T6[0] :62.7/62.7 Hz T7[0] : 4.1/4.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :26.7/13340.0 Hz T2[+] : 9.8/196905.4 Hz T3[+] :742.7/1485.5 Hz T4[+] : 9.7/965.6 Hz
T5[+] : 7.3/7.3 Hz T6[+] :62.6/62.6 Hz T7[+] : 4.1/4.1 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :26.7/13330.4 Hz T2[-] : 9.8/196928.5 Hz T3[-] :743.2/1486.5 Hz T4[-] : 9.7/966.0 Hz
T5[-] : 7.3/7.3 Hz T6[-] :62.7/62.7 Hz T7[-] :787.1/787.1 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 42456/21228258 T2[0] : 15673/313476297 T3[0] :1182913/2365827 T4[0] : 15378/1537838
T5[0] : 11588/11588 T6[0] : 99782/99782 T7[0] : 6451/6451 T8[0] : 24/1629889
T1[+] : 20870/10435151 T2[+] : 7701/154028441 T3[+] : 580997/1161994 T4[+] : 7553/755326
T5[+] : 5674/5674 T6[+] : 48983/48983 T7[+] : 3236/3236 T8[+] : 12/801020
T1[-] : 20856/10428145 T2[-] : 7702/154053853 T3[-] : 581421/1162843 T4[-] : 7557/755700
T5[-] : 5715/5715 T6[-] : 49040/49040 T7[-] : 615706/615706 T8[-] : 12/801058
AVERAGE CURRENT
BCM x1 : 89.9304uA BCM x3 : 89.5868uA BCM x10: 49.2724uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 20.07 ppm BCM u3 : 19.48 ppm BCM u10: 21.18 ppm
BCM d1 : 19.62 ppm BCM d3 : 18.02 ppm BCM d10: 20.64 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1435 BCM u3 [0]:0.1433 BCM u10[0]:0.08119
BCM u1 [+]:0.07049 BCM u3 [+]:0.07038 BCM u10[+]:0.03988
BCM u1 [-]:0.07049 BCM u3 [-]:0.07038 BCM u10[-]:0.03988
BCM d1 [0]:0.1428 BCM d3 [0]:0.1419 BCM d10[0]:0.07567
BCM d1 [+]:0.07018 BCM d3 [+]:0.06974 BCM d10[+]:0.03718
BCM d1 [-]:0.07018 BCM d3 [-]:0.06974 BCM d10[-]:0.03718
Right S1 scintillators
S1R [0]:9.846E+05 S1R [1]:8.363E+06 S1R [2]:6.831E+06
S1R [3]:4.811E+06 S1R [4]:1.595E+07 S1R [5]:3.077E+06
Right S1 scintillators rates
S1L [0]:678.5 Hz S1L [1]:17797.0 Hz S1L [2]:4164.4 Hz
S1L [3]:3194.8 Hz S1L [4]:2560.3 Hz S1L [5]:6119.5 Hz
Right S1 scintillators normalized by charge
S1L [0]:7527655.800000 S1L [1]:197460380.000000 S1L [2]:46204999.000000
S1L [3]:35447052.000000 S1L [4]:28406716.000000 S1L [5]:67896395.000000
S1R [0]:6863259.000000 S1R [1]:58298167.000000 S1R [2]:47615196.000000
S1R [3]:33534805.000000 S1R [4]:111205040.000000 S1R [5]:21447074.000000
Right arm S2 scintillators
S2 [0]:1.025E+07 S2 [1]:1.15E+07 S2 [2]:1.56E+07 S2 [3]:2.399E+07
S2 [4]:3.07E+07 S2 [5]:3.287E+07 S2 [6]:3.04E+07 S2 [7]:3.281E+07
S2 [8]:3.128E+07 S2 [9]:2.952E+07 S2 [10]:3.033E+07 S2 [11]:3.035E+07
S2 [12]:4.162E+07 S2 [13]:2.614E+07 S2 [14]:1.843E+07 S2 [15]:1.399E+07
S2 [16]:1.011E+07 S2 [17]:1.363E+07 S2 [18]:1.993E+07 S2 [19]:2.407E+07
S2 [20]:3.1E+07 S2 [21]:3.287E+07 S2 [22]:3.136E+07 S2 [23]:3.388E+07
S2 [24]:3.036E+07 S2 [25]:3.08E+07 S2 [26]:2.791E+07 S2 [27]:2.768E+07
S2 [28]:2.504E+07 S2 [29]:2.214E+07 S2 [30]:2.132E+07 S2 [31]:1.285E+07
Right arm S2 scintillators rates
S2 [0]:6441.7 Hz S2 [1]:7224.0 Hz S2 [2]:9800.6 Hz S2 [3]:15069.1 Hz
S2 [4]:19285.6 Hz S2 [5]:20649.0 Hz S2 [6]:19099.9 Hz S2 [7]:20611.0 Hz
S2 [8]:19651.6 Hz S2 [9]:18547.5 Hz S2 [10]:19057.4 Hz S2 [11]:19068.5 Hz
S2 [12]:26148.0 Hz S2 [13]:16420.3 Hz S2 [14]:11577.3 Hz S2 [15]:8789.1 Hz
S2 [16]:6353.8 Hz S2 [17]:8563.9 Hz S2 [18]:12523.6 Hz S2 [19]:15119.6 Hz
S2 [20]:19476.0 Hz S2 [21]:20652.5 Hz S2 [22]:19699.7 Hz S2 [23]:21285.7 Hz
S2 [24]:19073.3 Hz S2 [25]:19351.4 Hz S2 [26]:17532.5 Hz S2 [27]:17387.3 Hz
S2 [28]:15732.9 Hz S2 [29]:13911.4 Hz S2 [30]:13392.3 Hz S2 [31]:8073.4 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:71471917.000000 S2 [ 1]:80151848.000000 S2 [ 2]:108738650.000000
S2 [ 3]:167194080.000000 S2 [ 4]:213977010.000000 S2 [ 5]:229103690.000000
S2 [ 6]:211916750.000000 S2 [ 7]:228681890.000000 S2 [ 8]:218037490.000000
S2 [ 9]:205787860.000000 S2 [10]:211444870.000000 S2 [11]:211568320.000000
S2 [12]:290115760.000000 S2 [13]:182186170.000000 S2 [14]:128452390.000000
S2 [15]:97516687.000000 S2 [16]:70496140.000000 S2 [17]:95017801.000000
S2 [18]:138951500.000000 S2 [19]:167754720.000000 S2 [20]:216088870.000000
S2 [21]:229143040.000000 S2 [22]:218570890.000000 S2 [23]:236168650.000000
S2 [24]:211621070.000000 S2 [25]:214706900.000000 S2 [26]:194525450.000000
S2 [27]:192914730.000000 S2 [28]:174559160.000000 S2 [29]:154348680.000000
S2 [30]:148589980.000000 S2 [31]:89576192.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 55158896.000000
Right arm S2m : 175293100.000000
Left arm S1 scintillators
S1R [0]:7.799E+06 S1R [1]:1.074E+07 S1R [2]:1.642E+07
S1R [3]:1.344E+07 S1R [4]:1.597E+07 S1R [5]:9.872E+06
S1L [0]:7.142E+06 S1L [1]:8.893E+06 S1L [2]:1.352E+07
S1L [3]:1.414E+07 S1L [4]:1.543E+07 S1L [5]:1.042E+07
Left arm S1 scintillators rates
S1R [0]:4899.8 Hz S1R [1]:6745.2 Hz S1R [2]:10314.3 Hz
S1R [3]:8444.5 Hz S1R [4]:10035.9 Hz S1R [5]:6202.1 Hz
S1L [0]:4487.2 Hz S1L [1]:5587.1 Hz S1L [2]:8495.7 Hz
S1L [3]:8882.6 Hz S1L [4]:9696.4 Hz S1L [5]:6543.6 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:54363899.0 S1R [1]:74838528.0 S1R [2]:114438820.0
S1R [3]:93692653.0 S1R [4]:111349450.0 S1R [5]:68813382.0
S1L [0]:49786516.0 S1L [1]:61989884.0 S1L [2]:94261043.0
S1L [3]:98553820.0 S1L [4]:107582820.0 S1L [5]:72601754.0
Left arm S2 scintillators
S2R [0]:2.102E+07 S2R [1]:2.094E+07 S2R [2]:3.018E+07
S2R [3]:4.804E+07 S2R [4]:4.775E+07 S2R [5]:3.419E+07
S2L [0]:3.983E+07 S2L [1]:2.414E+07 S2L [2]:4.007E+07
S2L [3]:3.354E+07 S2L [4]:3.268E+07 S2L [5]:3.868E+07
Left arm S2 scintillators rates
S2R [0]:13203.8 Hz S2R [1]:13154.9 Hz S2R [2]:18960.2 Hz
S2R [3]:30184.2 Hz S2R [4]:29998.1 Hz S2R [5]:21479.9 Hz
S2L [0]:25025.8 Hz S2L [1]:15167.6 Hz S2L [2]:25176.1 Hz
S2L [3]:21072.5 Hz S2L [4]:20531.5 Hz S2L [5]:24298.4 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:146497770.0 S2R [1]:145955260.0 S2R [2]:210366350.0
S2R [3]:334898540.0 S2R [4]:332833930.0 S2R [5]:238322630.0
S2L [0]:277664690.0 S2L [1]:168286750.0 S2L [2]:279333250.0
S2L [3]:233803040.0 S2L [4]:227800060.0 S2L [5]:269594300.0
Left arm Gas Cerenkov
GasC [0]:1.84E+07 GasC [1]:1.392E+07 GasC [2]:1.583E+07
GasC [3]:1.562E+07 GasC [4]:1.674E+07 GasC [5]:1.546E+07
GasC [6]:1.523E+07 GasC [7]:1.537E+07 GasC [8]:1.323E+07
GasC [9]:2.799E+07
Left arm Gas Cerenkov rates
GasC [0]:11563.2 Hz GasC [1]:8747.5 Hz GasC [2]:9946.0 Hz
GasC [3]:9811.8 Hz GasC [4]:10519.2 Hz GasC [5]:9715.6 Hz
GasC [6]:9566.7 Hz GasC [7]:9655.5 Hz GasC [8]:8311.2 Hz
GasC [9]:17586.4 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:128295160.0 GasC [1]:97054677.0 GasC [2]:110352460.0
GasC [3]:108863160.0 GasC [4]:116712500.0 GasC [5]:107796560.0
GasC [6]:106143630.0 GasC [7]:107128860.0 GasC [8]:92214282.0
GasC [9]:195123380.0
Average of detectors sum of detectors charge normalized
Left S1 : 83522717.000000
Left S2 : 238779720.000000
Gas Cerenkov : 116968470.000000
****************************
End-of-run EPICS data for Run Number 3031 at Mon Apr 30 20:12:51 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.72798
Left Arm arm angle : 21.5458
Right Arm D1 momentum : 0.7272
Right Arm arm angle : 68.3281
HALLA:p : 4051.27
HALLA:dpp : 0
Tiefenbach Hall A energy : 4051.27
Left Arm Top VDC Current : -3.41797
Left Arm Bottom VDC Current : -1.2207
Left Arm Q1 momentum : 3.72787
Left Arm Q1 power supply : 2804.59
Left Arm Q1 gauss meter : -0.23633
Left Arm Q2 gauss meter : 0.8443
Left Arm Q2 power supply current : 1605.14
Left Arm Q2 momentum : 3.72768
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1357.53
Left Arm D1 momentum : 3.72798
Left Arm D1 NMR : 1.38097
Left Arm Q3 gauss meter : -0.7407
Left Arm Q3 power supply current : 1484.05
Left Arm Q3 momentum : 3.72767
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.727302
Right Arm Q1 power supply : 546.883
Right Arm Q1 gauss meter : 0.013805
Right Arm Q2 power supply current : 312.924
Right Arm Q2 momentum : 0.727108
Right Arm Q2 gauss meter : -0.16541
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 249.979
Right Arm D1 momentum : 0.727201
Right Arm D1 NMR : 0.269855
Right Arm Q3 power supply current : 289.391
Right Arm Q3 momentum : 0.727279
Right Arm Q3 gauss meter : -0.1302
Right Arm Q3 power supply polarity : enabled