NEXT
User name a-onl
Log entry time 20:13:49 on April 30, 2007
Entry number 200659
keyword=Start_Run_3032,Run_type=4He Production,target_type=4He 20cm,target_colli=out,beam_e0=4.057,beam_raster=on,leftarm_p=3.728,leftarm_theta=21.55,leftarm_colli=out,rightarm_p=.7272,rightarm_theta=68.30,rightarm_colli=out,comment_text=100uA
Run Timestamp: Mon Apr 30 20:13:18 EDT 2007
Beginning-of-run EPICS data for Run Number 3032 at Mon Apr 30 20:13:36 EDT 2007
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=4.057
beam_raster=on
leftarm_p=3.728
leftarm_theta=21.55
leftarm_colli=out
rightarm_p=.7272
rightarm_theta=68.30
rightarm_colli=out
comment_text=100uA
; Spectrometer DAQ on adaql2/a-onl account
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = Right arm trigger
; T2 = Right arm efficiency trigger
; T3 = Left arm trigger.
; T4 = Left arm efficiency trigger
; T5 = T1.and.T3 (main coincidence trigger)
; T6 = T3.and.R-arm-retiming
; T7 = T1.and.T4
; T8 = 1024 Hz pulser
; String should be one line, no spaces, ending in carriage return.
ps1=500,ps2=20000,ps3=2,ps4=100,ps5=1,ps6=1,ps7=1,ps8=65535
Left Arm Q1 momentum : 3.72794
Left Arm Q1 power supply : 2804.65
Left Arm Q1 gauss meter : -0.23634
Left Arm Q2 power supply current : 1605.01
Left Arm Q2 momentum : 3.72738
Left Arm Q2 gauss meter : 0.8443
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1357.53
Left Arm D1 momentum : 3.72799
Left Arm D1 NMR : 1.38097
Left Arm Q3 power supply current : 1484.17
Left Arm Q3 momentum : 3.72796
Left Arm Q3 gauss meter : -0.7408
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -1.3387
Right Arm Q1 momentum : 0.727302
Right Arm Q1 power supply : 546.883
Right Arm Q1 gauss meter : 0.013803
Right Arm Q2 power supply current : 312.82
Right Arm Q2 momentum : 0.726866
Right Arm Q2 gauss meter : -0.16541
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 249.979
Right Arm D1 momentum : 0.7272
Right Arm D1 NMR : 0.269855
Right Arm Q3 power supply current : 289.222
Right Arm Q3 momentum : 0.726854
Right Arm Q3 gauss meter : -0.13023
Right Arm Q3 power supply polarity : enabled
Right Arm B Field Hall Probe (D-G) : 0.267
Left Arm Top VDC Current : 3.56445
Left Arm Bottom VDC Current : -2.05078
Left Arm Top VDC voltage : 3.99902
Left Arm Bottom VDC voltage : 4.00244
Right Arm Top VDC voltage : 3.64111
Right Arm Bottom VDC voltage : 3.65234
-----
Average current of the two cavities : 100.724
Current on Unser monitor : 95.9004
Current on Upstream bcm : 101.727
Current on Downstream bcm : 99.722
Upstream Cavity Coefficient : 43.47
Downstream Cavity Coefficient : 42.89
Current on IBC0L02 (source) : 100.578
Hall C Current : 0.064755
Hall A momentum (Tiefenbach) (HALLA:p) : 4051.27
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 4056.9
Hall A energy (halla_MeV) : 4051.27
Hall C energy (hallc_MeV) : 5060.55
Delta(E)/E width (MV_AI_DXWID) : 0.854714
MBSY1c magnet current (amp) : 169.173
MBSY1c Bdl : 1.01294e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.871533
HacL_HPE1313A:0_Ch58 : -0.144043
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.143555
Left Arm Angle Floor Angle : 21.5
Left Arm Angle Vernier : 39
Left Arm Scattering Angle : 21.5458
Right Arm Arm Collimator : 0.862988
HacR_HPE1313A:0_Ch58 : -0.557617
HacR_HPE1313A:0_Ch55 : 21.6309
HacR_HPE1313A:0_Ch54 : -0.869629
Right Arm Angle Floor Angle : 68.5
Right Arm Angle Vernier : -64
Right Arm Scattering Angle : 68.3281
-----
IPM1C12.XPOS : 0.0148393
IPM1C12.YPOS : -0.173022
IPM1H04A.XPOS : -2.32436
IPM1H04A.YPOS : 1.00318
IPM1H04B.XPOS : -2.25013
IPM1H04B.YPOS : 1.00423
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 0.195965
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 0
Laser attenuation Hall A : 197
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 8500
Beam Half-wave plate (off=out) : OUT
Arc OTR x-position : -1.32257
Arc OTR y-position : 0.411166
Arc OTR x-width : 1.79387
Arc OTR y-width : 1.19989
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----
Target : Loop1 20cm
fan frequency loop 1 : 60
fan frequency loop 2 : 180
Encoder position : 3.30505e+07
Target type : 3.30505e+07
temperature loop 1(1) : 8.54
temperature loop 1(2) : 8.51
temperature loop 1(3) : 8.88
Heat exchange He : 9.6
temperature loop 3(1) : 99.99
temperature loop 3(2) : 120.47
temperature loop 3(3) : 99.99
Heat exchange H2 : 253.6
pressure loop He : 206.574
pressure loop H2 before : 22.9648
pressure loop H2 return : 23.4577
HPH He loop : 53.9071
Fan speed He loop : 60
HPH H2 loop : 0.00634721
Fan speed H2 loop : 0
SLI data valid? : Yes
SLI horiz size mm : 0.285955
SLI Energy spread *10^5 : 5.29547
SLI x position : 1.25217
SLI vert. size mm : 0.133342
SLI y position : 1.4723
MF7b1461_0ch0property.F : -2341.2
MF7b1461_0ch1property.F : -2131.9
MF7b1461_0ch2property.F : -2224.2
MF7b1461_0ch3property.F : -2180.4
MF7b1461_0ch4property.F : -2400
MF7b1461_0ch5property.F : -2096.7
MF7b1461_0ch6property.F : -1907.1
MF7b1461_0ch7property.F : -1836.9
MF7b1461_0ch8property.F : -2003.2
MF7b1461_0ch9property.F : -1910.1
MF7b1461_0ch10property.F : -2086.2
MF7b1461_0ch11property.F : -1887
MF7b1461_1ch0property.F : -1718.6
MF7b1461_1ch1property.F : -1649.2
MF7b1461_1ch2property.F : -1789.3
MF7b1461_1ch3property.F : -1644
MF7b1461_1ch4property.F : -1993.7
MF7b1461_1ch5property.F : -1750.3
MF7b1461_1ch6property.F : -2098.4
MF7b1461_1ch7property.F : -2059.9
MF7b1461_1ch8property.F : -2182.2
MF7b1461_1ch9property.F : -1939
MF7b1461_1ch10property.F : -1857
MF7b1461_1ch11property.F : -2012.7
MF7b1461_2ch0property.F : -1616.9
MF7b1461_2ch1property.F : -1598.6
MF7b1461_2ch2property.F : -1515
MF7b1461_2ch3property.F : -1466.6
MF7b1461_2ch4property.F : -1852.1
MF7b1461_2ch5property.F : -1952.1
MF7b1461_2ch6property.F : -1801.3
MF7b1461_2ch7property.F : -1799.6
MF7b1461_2ch8property.F : -1961.6
MF7b1461_2ch9property.F : -1898
MF7b1461_2ch10property.F : -18.8
MF7b1461_2ch11property.F : -22.8
MF7b1461_3ch0property.F : -860.4
MF7b1461_3ch1property.F : -785.2
MF7b1461_3ch2property.F : -905.8
MF7b1461_3ch3property.F : -981.2
MF7b1461_3ch4property.F : -760.2
MF7b1461_3ch5property.F : -860.9
MF7b1461_3ch6property.F : -1081.3
MF7b1461_3ch7property.F : -990.8
MF7b1461_3ch8property.F : -810.5
MF7b1461_3ch9property.F : -790.9
MF7b1461_3ch10property.F : -860
MF7b1461_3ch11property.F : -785.3
MF7b1461_4ch0property.F : -870.1
MF7b1461_4ch1property.F : -901.3
MF7b1461_4ch2property.F : -750.8
MF7b1461_4ch3property.F : -895.1
MF7b1461_4ch4property.F : -921.7
MF7b1461_4ch5property.F : -822
MF7b1461_4ch6property.F : -810.4
MF7b1461_4ch7property.F : -801.1
MF7b1461_4ch8property.F : -1160.4
MF7b1461_4ch9property.F : -991.4
MF7b1461_4ch10property.F : -1030.9
MF7b1461_4ch11property.F : -836.3
MF7b1461_5ch0property.F : -1041.1
MF7b1461_5ch1property.F : -871
MF7b1461_5ch2property.F : -917
MF7b1461_5ch3property.F : -735.8
MF7b1461_5ch4property.F : -890.7
MF7b1461_5ch5property.F : -810.3
MF7b1461_5ch6property.F : -821.1
MF7b1461_5ch7property.F : -871
MF7b1461_5ch8property.F : -741.3
MF7b1461_5ch9property.F : -841.4
MF7b1461_5ch10property.F : -16.5
MF7b1461_5ch11property.F : -25.6
MF7b1461_9ch0property.F : -921.4
MF7b1461_9ch1property.F : -881.5
MF7b1461_9ch2property.F : -798.8
MF7b1461_9ch3property.F : -870.2
MF7b1461_9ch4property.F : -810.5
MF7b1461_9ch5property.F : -941.2
MF7b1461_9ch6property.F : -850.1
MF7b1461_9ch7property.F : -889.8
MF7b1461_9ch8property.F : -810.4
MF7b1461_9ch9property.F : -780.3
MF7b1461_9ch10property.F : -819.7
MF7b1461_9ch11property.F : -850.3
MF7b1461_10ch0property.F : -755.7
MF7b1461_10ch1property.F : -812.4
MF7b1461_10ch2property.F : -871
MF7b1461_10ch3property.F : -900.8
MF7b1461_10ch4property.F : -881.4
MF7b1461_10ch5property.F : -871
MF7b1461_10ch6property.F : -815.2
MF7b1461_10ch7property.F : -824.8
MF7b1461_10ch8property.F : -760.3
MF7b1461_10ch9property.F : -715.7
MF7b1461_10ch10property.F : -911
MF7b1461_10ch11property.F : -781.3
MF7b1461_11ch0property.F : -1000.7
MF7b1461_11ch1property.F : -900.4
MF7b1461_11ch2property.F : -850.6
MF7b1461_11ch3property.F : -1079.9
MF7b1461_11ch4property.F : -1050.2
MF7b1461_11ch5property.F : -800
MF7b1461_11ch6property.F : -860.4
MF7b1461_11ch7property.F : -1031.3
MF7b1461_11ch8property.F : -911.3
MF7b1461_11ch9property.F : -880.3
MF7b1461_11ch10property.F : -12.9
MF7b1461_11ch11property.F : -24.7
MF3b1461_1ch0property.F : -1978.8
MF3b1461_1ch1property.F : -1888.6
MF3b1461_1ch2property.F : -1986.4
MF3b1461_1ch3property.F : -2000.5
MF3b1461_1ch4property.F : -1770.7
MF3b1461_1ch5property.F : -1627.6
MF3b1461_1ch6property.F : -1969.4
MF3b1461_1ch7property.F : -1800.6
MF3b1461_1ch8property.F : -1846.2
MF3b1461_1ch9property.F : -1806.8
MF3b1461_1ch10property.F : -1859.1
MF3b1461_1ch11property.F : -1804.7
MF3b1461_10ch0property.F : -1785.8
MF3b1461_10ch1property.F : -1896.5
MF3b1461_10ch2property.F : -2003.5
MF3b1461_10ch3property.F : -1890.8
MF3b1461_10ch4property.F : -1999.4
MF3b1461_10ch5property.F : -1896.9
MF3b1461_10ch6property.F : -1969.5
MF3b1461_10ch7property.F : -1789.4
MF3b1461_10ch8property.F : -1978.9
MF3b1461_10ch9property.F : -1968.8
MF3b1461_10ch10property.F : -17.9
MF3b1461_10ch11property.F : -20.6
MF3b1461_11ch0property.F : -1790.8
MF3b1461_11ch1property.F : -1807.8
MF3b1461_11ch2property.F : -2000.3
MF3b1461_11ch3property.F : -1872.8
MF3b1461_11ch4property.F : -1891.5
MF3b1461_11ch5property.F : -1680.1
MF3b1461_11ch6property.F : -1803.8
MF3b1461_11ch7property.F : -1778.2
MF3b1461_11ch8property.F : -1731
MF3b1461_11ch9property.F : -1900.6
MF3b1461_11ch10property.F : -16.7
MF3b1461_11ch11property.F : -22.2
MF3b1461_14ch0property.F : -19.3
MF3b1461_14ch1property.F : -21
MF3b1461_14ch2property.F : -18.8
MF3b1461_14ch3property.F : -18.9
MF3b1461_14ch4property.F : -16.6
MF3b1461_14ch5property.F : -16.7
MF3b1461_14ch6property.F : -18.8
MF3b1461_14ch7property.F : -19.2
MF3b1461_14ch8property.F : -19.6
MF3b1461_14ch9property.F : -17.7
MF3b1461_14ch10property.F : -20.3
MF3b1461_14ch11property.F : -26.9
LVDT Position Ch1 : -752
LVDT Position Ch2 : 1378
LVDT Position Ch2 : 827
L_VMIC1182 for iocha18 : 233905
RVDT Position Ch1 : -3154
RVDT Position Ch2 : -2019
RVDT Position Ch2 : 3214
R_VMIC1182 for iocha19 : 107066