Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:35:20 on April 30, 2007

    Entry number 200668

    keyword=End_of_Run_3036
    ****************************
     Run Number: 3036
     End of Run Comment:
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=4.057
    beam_raster=on
    leftarm_p=3.728
    leftarm_theta=21.55
    leftarm_colli=out
    rightarm_p=.7272
    rightarm_theta=68.30
    rightarm_colli=out
    comment_text=100uA
     
    
    PRESCALE FACTORS:ps1=500   ps2=20000   ps3=2   ps4=100   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1253394      [+]: 616412       [-]: 615311       
    TIME  [0]: 30.396 mins  [+]: 14.942 mins  [-]: 14.944 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         1.89221 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  95.11%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :23.3/11628.5 Hz   T2[0] : 8.6/172825.1 Hz   T3[0] :648.1/1296.3 Hz   T4[0] : 8.4/843.1 Hz   
    T5[0] : 6.8/6.8  Hz   T6[0] :54.5/54.5 Hz   T7[0] : 3.5/3.5  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :23.2/11622.6 Hz   T2[+] : 8.6/172762.5 Hz   T3[+] :648.7/1297.3 Hz   T4[+] : 8.4/842.9 Hz   
    T5[+] : 6.8/6.8  Hz   T6[+] :54.5/54.5 Hz   T7[+] : 3.5/3.5  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :23.3/11625.3 Hz   T2[-] : 8.6/172733.6 Hz   T3[-] :647.0/1294.0 Hz   T4[-] : 8.4/842.3 Hz   
    T5[-] : 6.8/6.8  Hz   T6[-] :54.5/54.5 Hz   T7[-] :686.2/686.2 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42415/21207535  T2[0] :  15759/315191396  T3[0] :1182034/2364069  T4[0] :  15375/1537585  
    T5[0] :  12416/12416    T6[0] :  99413/99413    T7[0] :   6398/6398     T8[0] :     28/1867529  
    
    T1[+] :  20840/10420168  T2[+] :   7744/154888830  T3[+] : 581547/1163095  T4[+] :   7556/755660   
    T5[+] :   6066/6066     T6[+] :  48836/48836    T7[+] :   3121/3121     T8[+] :     14/918059   
    
    T1[-] :  20847/10423678  T2[-] :   7743/154878752  T3[-] : 580103/1160206  T4[-] :   7552/755245   
    T5[-] :   6130/6130     T6[-] :  48871/48871    T7[-] : 615311/615311   T8[-] :     14/918153   
    
    
    AVERAGE CURRENT
    BCM x1 : 78.3631uA  BCM x3 : 78.0870uA  BCM x10: 44.3846uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    86.04 ppm     BCM u3 :    86.48 ppm     BCM u10:    98.27 ppm     
    BCM d1 :    85.85 ppm     BCM d3 :    87.19 ppm     BCM d10:    98.58 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1432         BCM u3 [0]:0.143          BCM u10[0]:0.08352        
    BCM u1 [+]:0.07038        BCM u3 [+]:0.07028        BCM u10[+]:0.04104        
    BCM u1 [-]:0.07038        BCM u3 [-]:0.07028        BCM u10[-]:0.04103        
    
    BCM d1 [0]:0.1426         BCM d3 [0]:0.1418         BCM d10[0]:0.07837        
    BCM d1 [+]:0.07006        BCM d3 [+]:0.06967        BCM d10[+]:0.03851        
    BCM d1 [-]:0.07006        BCM d3 [-]:0.06966        BCM d10[-]:0.03851        
    
    
    
    
    Right S1 scintillators
    S1R [0]:9.775E+05      S1R [1]:8.335E+06      S1R [2]:6.86E+06       
    S1R [3]:4.816E+06      S1R [4]:1.604E+07      S1R [5]:3.066E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:591.3 Hz   S1L [1]:15606.1 Hz   S1L [2]:3632.4 Hz   
    S1L [3]:2788.7 Hz   S1L [4]:2236.4 Hz   S1L [5]:5366.2 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:7528352.400000   S1L [1]:198703980.000000   S1L [2]:46249748.000000   
    S1L [3]:35506468.000000   S1L [4]:28474613.000000   S1L [5]:68324680.000000   
    S1R [0]:6824604.900000   S1R [1]:58191814.000000   S1R [2]:47889075.000000   
    S1R [3]:33620411.000000   S1R [4]:111977300.000000   S1R [5]:21408507.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.036E+07      S2  [1]:1.159E+07      S2  [2]:1.569E+07      S2  [3]:2.412E+07      
    S2  [4]:3.083E+07      S2  [5]:3.3E+07        S2  [6]:3.052E+07      S2  [7]:3.294E+07      
    S2  [8]:3.139E+07      S2  [9]:2.965E+07      S2  [10]:3.047E+07      S2  [11]:3.048E+07      
    S2  [12]:4.178E+07      S2  [13]:2.628E+07      S2  [14]:1.854E+07      S2  [15]:1.41E+07       
    S2  [16]:1.022E+07      S2  [17]:1.375E+07      S2  [18]:2.007E+07      S2  [19]:2.421E+07      
    S2  [20]:3.114E+07      S2  [21]:3.303E+07      S2  [22]:3.15E+07       S2  [23]:3.402E+07      
    S2  [24]:3.048E+07      S2  [25]:3.095E+07      S2  [26]:2.803E+07      S2  [27]:2.782E+07      
    S2  [28]:2.516E+07      S2  [29]:2.226E+07      S2  [30]:2.145E+07      S2  [31]:1.295E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:5682.1 Hz   S2  [1]:6355.7 Hz   S2  [2]:8603.3 Hz   S2  [3]:13223.9 Hz   
    S2  [4]:16903.1 Hz   S2  [5]:18093.9 Hz   S2  [6]:16736.1 Hz   S2  [7]:18059.0 Hz   
    S2  [8]:17212.3 Hz   S2  [9]:16260.2 Hz   S2  [10]:16704.9 Hz   S2  [11]:16713.3 Hz   
    S2  [12]:22908.6 Hz   S2  [13]:14411.2 Hz   S2  [14]:10167.2 Hz   S2  [15]:7732.3 Hz   
    S2  [16]:5606.1 Hz   S2  [17]:7538.9 Hz   S2  [18]:11007.4 Hz   S2  [19]:13272.3 Hz   
    S2  [20]:17073.7 Hz   S2  [21]:18109.6 Hz   S2  [22]:17274.4 Hz   S2  [23]:18656.2 Hz   
    S2  [24]:16710.4 Hz   S2  [25]:16970.2 Hz   S2  [26]:15370.2 Hz   S2  [27]:15254.0 Hz   
    S2  [28]:13796.4 Hz   S2  [29]:12203.2 Hz   S2  [30]:11759.1 Hz   S2  [31]:7100.0 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:72347113.000000   S2  [ 1]:80922908.000000   S2  [ 2]:109541190.000000   
    S2  [ 3]:168372110.000000   S2  [ 4]:215217790.000000   S2  [ 5]:230378800.000000   
    S2  [ 6]:213091080.000000   S2  [ 7]:229934890.000000   S2  [ 8]:219154770.000000   
    S2  [ 9]:207031800.000000   S2  [10]:212693430.000000   S2  [11]:212800450.000000   
    S2  [12]:291681600.000000   S2  [13]:183489970.000000   S2  [14]:129452950.000000   
    S2  [15]:98451397.000000   S2  [16]:71379014.000000   S2  [17]:95988305.000000   
    S2  [18]:140151040.000000   S2  [19]:168988850.000000   S2  [20]:217389370.000000   
    S2  [21]:230578380.000000   S2  [22]:219944550.000000   S2  [23]:237538630.000000   
    S2  [24]:212763170.000000   S2  [25]:216071570.000000   S2  [26]:195699440.000000   
    S2  [27]:194220740.000000   S2  [28]:175661270.000000   S2  [29]:155376030.000000   
    S2  [30]:149721750.000000   S2  [31]:90400206.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 55391629.000000   
    Right arm S2m  : 176451080.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.05E+06       S1R [1]:1.098E+07      S1R [2]:1.666E+07      
    S1R [3]:1.362E+07      S1R [4]:1.621E+07      S1R [5]:1.001E+07      
    S1L [0]:7.381E+06      S1L [1]:9.106E+06      S1L [2]:1.377E+07      
    S1L [3]:1.435E+07      S1L [4]:1.562E+07      S1L [5]:1.057E+07      
    
    
    Left arm S1 scintillators rates
    S1R [0]:4413.9 Hz   S1R [1]:6018.5 Hz   S1R [2]:9137.2 Hz   
    S1R [3]:7466.4 Hz   S1R [4]:8889.4 Hz   S1R [5]:5486.2 Hz   
    S1L [0]:4047.3 Hz   S1L [1]:4993.1 Hz   S1L [2]:7549.0 Hz   
    S1L [3]:7865.7 Hz   S1L [4]:8562.6 Hz   S1L [5]:5794.1 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:56199562.0    S1R [1]:76629548.0    S1R [2]:116338870.0    
    S1R [3]:95065145.0    S1R [4]:113183510.0    S1R [5]:69852333.0    
    S1L [0]:51531768.0    S1L [1]:63574763.0    S1L [2]:96116833.0    
    S1L [3]:100148910.0    S1L [4]:109022070.0    S1L [5]:73773200.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.141E+07      S2R [1]:2.137E+07      S2R [2]:3.062E+07      
    S2R [3]:4.877E+07      S2R [4]:4.828E+07      S2R [5]:3.477E+07      
    S2L [0]:4.052E+07      S2L [1]:2.452E+07      S2L [2]:4.057E+07      
    S2L [3]:3.405E+07      S2L [4]:3.305E+07      S2L [5]:3.932E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:11737.5 Hz   S2R [1]:11720.3 Hz   S2R [2]:16791.4 Hz   
    S2R [3]:26739.1 Hz   S2R [4]:26472.0 Hz   S2R [5]:19065.2 Hz   
    S2L [0]:22218.1 Hz   S2L [1]:13447.3 Hz   S2L [2]:22244.9 Hz   
    S2L [3]:18667.6 Hz   S2L [4]:18122.5 Hz   S2L [5]:21561.4 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:149447220.0    S2R [1]:149227200.0    S2R [2]:213794470.0    
    S2R [3]:340453690.0    S2R [4]:337052010.0    S2R [5]:242746240.0    
    S2L [0]:282890240.0    S2L [1]:171216650.0    S2L [2]:283231630.0    
    S2L [3]:237684030.0    S2L [4]:230743490.0    S2L [5]:274528810.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.883E+07      GasC  [1]:1.421E+07      GasC  [2]:1.615E+07      
    GasC  [3]:1.594E+07      GasC  [4]:1.714E+07      GasC  [5]:1.579E+07      
    GasC  [6]:1.56E+07       GasC  [7]:1.574E+07      GasC  [8]:1.358E+07      
    GasC  [9]:3.572E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:10325.0 Hz   GasC  [1]:7793.2 Hz   GasC  [2]:8853.0 Hz   
    GasC  [3]:8742.8 Hz   GasC  [4]:9399.3 Hz   GasC  [5]:8658.7 Hz   
    GasC  [6]:8556.1 Hz   GasC  [7]:8632.3 Hz   GasC  [8]:7443.9 Hz   
    GasC  [9]:19587.8 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:131461900.0 GasC  [1]:99226292.0 GasC  [2]:112720520.0 
    GasC  [3]:111316480.0 GasC  [4]:119675220.0 GasC  [5]:110245840.0 
    GasC  [6]:108939410.0 GasC  [7]:109910340.0 GasC  [8]:94779228.0 
    GasC  [9]:249399950.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  85119708.000000   
    Left S2 :   242751310.000000   
    Gas Cerenkov :  124767520.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3036 at Mon Apr 30 22:35:18 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.72799
    Left Arm arm angle : 21.5458
    Right Arm D1 momentum : 0.7272
    Right Arm arm angle : 68.3281
    HALLA:p : 4051.27
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 4051.27
    Left Arm Top VDC Current : -3.71094
    Left Arm Bottom VDC Current : -1.26953
    Left Arm Q1 momentum : 3.72787
    Left Arm Q1 power supply : 2804.59
    Left Arm Q1 gauss meter : -0.23634
    Left Arm Q2 gauss meter : 0.8443
    Left Arm Q2 power supply current : 1605.19
    Left Arm Q2 momentum : 3.72734
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1357.53
    Left Arm D1 momentum : 3.72799
    Left Arm D1 NMR : 1.38097
    Left Arm Q3 gauss meter : -0.7408
    Left Arm Q3 power supply current : 1484.12
    Left Arm Q3 momentum : 3.72782
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.727373
    Right Arm Q1 power supply : 546.937
    Right Arm Q1 gauss meter : 0.0137947
    Right Arm Q2 power supply current : 312.956
    Right Arm Q2 momentum : 0.727183
    Right Arm Q2 gauss meter : -0.1654
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 249.979
    Right Arm D1 momentum : 0.7272
    Right Arm D1 NMR : 0.269855
    Right Arm Q3 power supply current : 289.342
    Right Arm Q3 momentum : 0.727157
    Right Arm Q3 gauss meter : -0.13022
    Right Arm Q3 power supply polarity : enabled