Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 16:29:14 on May 13, 2007

    Entry number 201962

    keyword=End_of_Run_3412
    ****************************
     Run Number: 3412
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=1.0544
    beam_raster=on
    leftarm_p=0.6198
    leftarm_theta=140.5
    leftarm_colli=out
    rightarm_p=0.7795
    rightarm_theta=14.627
    rightarm_colli=out
    comment_text=PRODUCTION 100uA
     61bQ2
     good  run but a short one
    
    PRESCALE FACTORS:ps1=1200   ps2=180000   ps3=4   ps4=500   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 37700        [+]: 17201        [-]: 17256        
    TIME  [0]: 1.268 mins  [+]: 0.594 mins  [-]: 0.594 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         3.68023 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  91.62%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :16.5/19811.4 Hz   T2[0] : 3.5/629690.4 Hz   T3[0] :332.7/1331.0 Hz   T4[0] : 3.6/1823.0 Hz   
    T5[0] : 9.9/9.9  Hz   T6[0] :217.7/217.7 Hz   T7[0] :13.7/13.7 Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :16.1/19369.8 Hz   T2[+] : 3.4/616120.4 Hz   T3[+] :325.1/1300.7 Hz   T4[+] : 3.6/1792.0 Hz   
    T5[+] : 8.7/8.7  Hz   T6[+] :210.8/210.8 Hz   T7[+] :13.4/13.4 Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :16.1/19381.6 Hz   T2[-] : 3.4/616013.4 Hz   T3[-] :324.7/1298.8 Hz   T4[-] : 3.5/1777.1 Hz   
    T5[-] :10.5/10.5 Hz   T6[-] :214.1/214.1 Hz   T7[-] :13.0/13.0 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1255/1507153  T2[0] :    266/47903818  T3[0] :  25314/101259   T4[0] :    277/138682   
    T5[0] :    756/756      T6[0] :  16564/16564    T7[0] :   1045/1045     T8[0] :      1/77901    
    
    T1[+] :    575/690087   T2[+] :    121/21950494  T3[+] :  11584/46339    T4[+] :    127/63844    
    T5[+] :    310/310      T6[+] :   7510/7510     T7[+] :    479/479      T8[+] :      0/36482    
    
    T1[-] :    575/690527   T2[-] :    121/21947281  T3[-] :  11568/46275    T4[-] :    126/63315    
    T5[-] :    374/374      T6[-] :   7628/7628     T7[-] :    464/464      T8[-] :      0/36483    
    
    
    AVERAGE CURRENT
    BCM x1 : 73.2558uA  BCM x3 : 72.9452uA  BCM x10: 38.0934uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    27.39 ppm     BCM u3 :    30.87 ppm     BCM u10:       53 ppm     
    BCM d1 :    25.54 ppm     BCM d3 :    41.28 ppm     BCM d10:    61.19 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005584       BCM u3 [0]:0.00557        BCM u10[0]:0.002995       
    BCM u1 [+]:0.002557       BCM u3 [+]:0.002551       BCM u10[+]:0.001372       
    BCM u1 [-]:0.002557       BCM u3 [-]:0.002551       BCM u10[-]:0.001372       
    
    BCM d1 [0]:0.005562       BCM d3 [0]:0.005528       BCM d10[0]:0.0028         
    BCM d1 [+]:0.002547       BCM d3 [+]:0.002532       BCM d10[+]:0.001283       
    BCM d1 [-]:0.002547       BCM d3 [-]:0.002532       BCM d10[-]:0.001283       
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.161E+04      S1R [1]:5.699E+05      S1R [2]:4.493E+05      
    S1R [3]:3.317E+05      S1R [4]:1.312E+06      S1R [5]:2.465E+05      
    
    
    Right S1 scintillators rates 
    S1L [0]:1358.4 Hz   S1L [1]:41401.8 Hz   S1L [2]:6135.1 Hz   
    S1L [3]:4741.0 Hz   S1L [4]:3703.5 Hz   S1L [5]:11285.8 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:18506302.000000   S1L [1]:564022630.000000   S1L [2]:83578845.000000   
    S1L [3]:64587609.000000   S1L [4]:50453059.000000   S1L [5]:153748030.000000   
    S1R [0]:14613754.000000   S1R [1]:102061330.000000   S1R [2]:80453811.000000   
    S1R [3]:59398201.000000   S1R [4]:234958260.000000   S1R [5]:44140853.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.183E+06      S2  [1]:1.524E+06      S2  [2]:2.287E+06      S2  [3]:3.639E+06      
    S2  [4]:4.845E+06      S2  [5]:5.363E+06      S2  [6]:5.094E+06      S2  [7]:5.598E+06      
    S2  [8]:5.601E+06      S2  [9]:5.504E+06      S2  [10]:5.791E+06      S2  [11]:5.897E+06      
    S2  [12]:7.704E+06      S2  [13]:5.206E+06      S2  [14]:3.638E+06      S2  [15]:2.625E+06      
    S2  [16]:1.192E+06      S2  [17]:1.76E+06       S2  [18]:2.766E+06      S2  [19]:3.61E+06       
    S2  [20]:4.894E+06      S2  [21]:5.347E+06      S2  [22]:5.308E+06      S2  [23]:5.545E+06      
    S2  [24]:5.373E+06      S2  [25]:5.76E+06       S2  [26]:5.342E+06      S2  [27]:5.547E+06      
    S2  [28]:4.921E+06      S2  [29]:4.384E+06      S2  [30]:4.127E+06      S2  [31]:2.431E+06      
    
    Right arm S2 scintillators rates
    S2  [0]:15556.0 Hz   S2  [1]:20038.4 Hz   S2  [2]:30057.6 Hz   S2  [3]:47835.9 Hz   
    S2  [4]:63691.4 Hz   S2  [5]:70496.3 Hz   S2  [6]:66958.1 Hz   S2  [7]:73585.1 Hz   
    S2  [8]:73619.3 Hz   S2  [9]:72344.5 Hz   S2  [10]:76125.5 Hz   S2  [11]:77511.4 Hz   
    S2  [12]:101262.8 Hz   S2  [13]:68435.8 Hz   S2  [14]:47818.8 Hz   S2  [15]:34507.6 Hz   
    S2  [16]:15668.2 Hz   S2  [17]:23131.9 Hz   S2  [18]:36360.8 Hz   S2  [19]:47459.0 Hz   
    S2  [20]:64331.8 Hz   S2  [21]:70287.8 Hz   S2  [22]:69766.9 Hz   S2  [23]:72884.0 Hz   
    S2  [24]:70624.6 Hz   S2  [25]:75713.0 Hz   S2  [26]:70218.8 Hz   S2  [27]:72915.3 Hz   
    S2  [28]:64690.8 Hz   S2  [29]:57630.9 Hz   S2  [30]:54251.8 Hz   S2  [31]:31950.4 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:211921010.000000   S2  [ 1]:272985680.000000   S2  [ 2]:409479140.000000   
    S2  [ 3]:651675960.000000   S2  [ 4]:867677540.000000   S2  [ 5]:960380960.000000   
    S2  [ 6]:912180660.000000   S2  [ 7]:1002461000.000000   S2  [ 8]:1002926600.000000   
    S2  [ 9]:985559950.000000   S2  [10]:1037069200.000000   S2  [11]:1055949400.000000   
    S2  [12]:1379517400.000000   S2  [13]:932310460.000000   S2  [14]:651442630.000000   
    S2  [15]:470101500.000000   S2  [16]:213450840.000000   S2  [17]:315128950.000000   
    S2  [18]:495348180.000000   S2  [19]:646540810.000000   S2  [20]:876401710.000000   
    S2  [21]:957541200.000000   S2  [22]:950445000.000000   S2  [23]:992909540.000000   
    S2  [24]:962128910.000000   S2  [25]:1031448800.000000   S2  [26]:956600520.000000   
    S2  [27]:993336090.000000   S2  [28]:881292420.000000   S2  [29]:785114050.000000   
    S2  [30]:739080920.000000   S2  [31]:435264650.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 122543560.000000   
    Right arm S2m  : 782364780.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:6.464E+05      S1R [1]:6.389E+05      S1R [2]:7.26E+05       
    S1R [3]:4.446E+05      S1R [4]:4.742E+05      S1R [5]:4.041E+05      
    S1L [0]:6.034E+05      S1L [1]:5.138E+05      S1L [2]:5.705E+05      
    S1L [3]:4.768E+05      S1L [4]:4.698E+05      S1L [5]:4.343E+05      
    
    
    Left arm S1 scintillators rates
    S1R [0]:8496.6 Hz   S1R [1]:8398.3 Hz   S1R [2]:9542.9 Hz   
    S1R [3]:5843.9 Hz   S1R [4]:6233.3 Hz   S1R [5]:5312.1 Hz   
    S1L [0]:7931.8 Hz   S1L [1]:6754.3 Hz   S1L [2]:7499.0 Hz   
    S1L [3]:6268.1 Hz   S1L [4]:6175.1 Hz   S1L [5]:5709.3 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:115750520.0    S1R [1]:114410680.0    S1R [2]:130004870.0    
    S1R [3]:79612876.0    S1R [4]:84917608.0    S1R [5]:72368049.0    
    S1L [0]:108056750.0    S1L [1]:92014161.0    S1L [2]:102159460.0    
    S1L [3]:85391440.0    S1L [4]:84124844.0    S1L [5]:77778434.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.873E+06      S2R [1]:1.504E+06      S2R [2]:1.696E+06      
    S2R [3]:2.449E+06      S2R [4]:2.306E+06      S2R [5]:1.85E+06       
    S2L [0]:3.556E+06      S2L [1]:1.794E+06      S2L [2]:2.374E+06      
    S2L [3]:1.629E+06      S2L [4]:1.503E+06      S2L [5]:2.135E+06      
    
    
    Left arm S2 scintillators rates
    S2R [0]:24626.6 Hz   S2R [1]:19769.1 Hz   S2R [2]:22288.9 Hz   
    S2R [3]:32191.3 Hz   S2R [4]:30317.6 Hz   S2R [5]:24317.4 Hz   
    S2L [0]:46743.5 Hz   S2L [1]:23579.5 Hz   S2L [2]:31210.2 Hz   
    S2L [3]:21417.8 Hz   S2L [4]:19754.5 Hz   S2L [5]:28061.1 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:335491540.0    S2R [1]:269317510.0    S2R [2]:303644890.0    
    S2R [3]:438546560.0    S2R [4]:413021780.0    S2R [5]:331278990.0    
    S2L [0]:636793420.0    S2L [1]:321226450.0    S2L [2]:425181310.0    
    S2L [3]:291777600.0    S2L [4]:269118740.0    S2L [5]:382281090.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.674E+06      GasC  [1]:1.303E+06      GasC  [2]:1.389E+06      
    GasC  [3]:1.418E+06      GasC  [4]:1.415E+06      GasC  [5]:1.353E+06      
    GasC  [6]:1.262E+06      GasC  [7]:1.305E+06      GasC  [8]:1.072E+06      
    GasC  [9]:2.171E+06      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:22010.4 Hz   GasC  [1]:17123.7 Hz   GasC  [2]:18262.9 Hz   
    GasC  [3]:18645.0 Hz   GasC  [4]:18604.7 Hz   GasC  [5]:17783.1 Hz   
    GasC  [6]:16584.7 Hz   GasC  [7]:17150.8 Hz   GasC  [8]:14087.7 Hz   
    GasC  [9]:28542.9 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:299851370.0 GasC  [1]:233278720.0 GasC  [2]:248798770.0 
    GasC  [3]:254003220.0 GasC  [4]:253454890.0 GasC  [5]:242261820.0 
    GasC  [6]:225935760.0 GasC  [7]:233647970.0 GasC  [8]:191919070.0 
    GasC  [9]:388844540.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  95549142.000000   
    Left S2 :   368139990.000000   
    Gas Cerenkov :  257199620.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3412 at Sun May 13 16:29:12 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.619784
    Left Arm arm angle : 140.5
    Right Arm D1 momentum : 0.779499
    Right Arm arm angle : 14.625
    HALLA:p : 1054.36
    HALLA:dpp : -2.71623e-06
    Tiefenbach Hall A energy : 1054.36
    Left Arm Top VDC Current : 4.05273
    Left Arm Bottom VDC Current : -0.78125
    Left Arm Q1 momentum : 0.619797
    Left Arm Q1 power supply : 466.293
    Left Arm Q1 gauss meter : -0.03922
    Left Arm Q2 gauss meter : 0.14122
    Left Arm Q2 power supply current : 266.903
    Left Arm Q2 momentum : 0.61984
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 205.459
    Left Arm D1 momentum : 0.619784
    Left Arm D1 NMR : 0.229558
    Left Arm Q3 gauss meter : -0.12269
    Left Arm Q3 power supply current : 246.637
    Left Arm Q3 momentum : 0.619507
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.779434
    Right Arm Q1 power supply : 586.084
    Right Arm Q1 gauss meter : 0.014792
    Right Arm Q2 power supply current : 335.411
    Right Arm Q2 momentum : 0.779359
    Right Arm Q2 gauss meter : -0.17725
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 267.56
    Right Arm D1 momentum : 0.779498
    Right Arm D1 NMR : 0.289262
    Right Arm Q3 power supply current : 310.243
    Right Arm Q3 momentum : 0.779429
    Right Arm Q3 gauss meter : -0.13958
    Right Arm Q3 power supply polarity : enabled