    keyword=End_of_Run_3925
    ****************************
     Run Number: 3925
     End of Run Comment:
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=2.094
    beam_raster=on
    leftarm_p=2.015
    leftarm_theta=20.851
    leftarm_colli=6msrd
    rightarm_p=0.5920
    rightarm_theta=63.039
    rightarm_colli=out
    comment_text=5 uA
     
    
    PRESCALE FACTORS:ps1=99999   ps2=99999   ps3=1   ps4=10   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 676992       [+]: 6295         [-]: 7008         
    TIME  [0]: 12.735 mins  [+]: 0.116 mins  [-]: 0.135 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       748.82002 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  86.22%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/1511.4 Hz   T2[0] : 0.3/27212.4 Hz   T3[0] :1022.0/1022.0 Hz   T4[0] : 5.4/54.0 Hz   
    T5[0] : 0.0/4.3  Hz   T6[0] : 0.0/9.8  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 0.0/1527.4 Hz   T2[+] : 0.1/27535.3 Hz   T3[+] :1043.6/1043.6 Hz   T4[+] : 5.2/53.2 Hz   
    T5[+] : 0.0/5.0  Hz   T6[+] : 0.0/12.7 Hz   T7[+] : 0.0/0.3  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 0.0/1487.3 Hz   T2[-] : 0.2/26884.4 Hz   T3[-] :997.4/997.4 Hz   T4[-] : 5.9/60.0 Hz   
    T5[-] : 0.0/4.3  Hz   T6[-] : 0.0/11.4 Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :     11/1154844  T2[0] :    207/20792825  T3[0] : 780920/780920   T4[0] :   4129/41297    
    T5[0] :      0/3255     T6[0] :      0/7505     T7[0] :      0/21       T8[0] :     11/782432   
    
    T1[+] :      0/10595    T2[+] :      1/190999   T3[+] :   7239/7239     T4[+] :     36/369      
    T5[+] :      0/35       T6[+] :      0/88       T7[+] :      0/2        T8[+] :      0/7103     
    
    T1[-] :      0/12042    T2[-] :      2/217674   T3[-] :   8076/8076     T4[-] :     48/486      
    T5[-] :      0/35       T6[-] :      0/92       T7[-] :      0/0        T8[-] :      0/8291     
    
    
    AVERAGE CURRENT
    BCM x1 : 4.2218 uA  BCM x3 : 4.1410 uA  BCM x10: 4.3586 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :1.473E+04 ppm     BCM u3 :1.545E+04 ppm     BCM u10:1.403E+04 ppm     
    BCM d1 :1.348E+04 ppm     BCM d3 :1.349E+04 ppm     BCM d10:1.337E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.003117       BCM u3 [0]:0.00299        BCM u10[0]:0.003323       
    BCM u1 [+]:2.875E-05      BCM u3 [+]:2.76E-05       BCM u10[+]:2.923E-05      
    BCM u1 [-]:3.258E-05      BCM u3 [-]:3.123E-05      BCM u10[-]:3.317E-05      
    
    BCM d1 [0]:0.003335       BCM d3 [0]:0.003338       BCM d10[0]:0.003337       
    BCM d1 [+]:3.071E-05      BCM d3 [+]:3.074E-05      BCM d10[+]:3.073E-05      
    BCM d1 [-]:3.49E-05       BCM d3 [-]:3.493E-05      BCM d10[-]:3.493E-05      
    
    
    
    
    Right S1 scintillators
    S1R [0]:4.474E+04      S1R [1]:3.768E+05      S1R [2]:3.519E+05      
    S1R [3]:3.072E+05      S1R [4]:6.613E+05      S1R [5]:1.69E+05       
    
    
    Right S1 scintillators rates 
    S1L [0]:60.3 Hz   S1L [1]:2655.3 Hz   S1L [2]:448.5 Hz   
    S1L [3]:406.8 Hz   S1L [4]:348.6 Hz   S1L [5]:534.8 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:14775625.000000   S1L [1]:650983540.000000   S1L [2]:109950720.000000   
    S1L [3]:99723517.000000   S1L [4]:85470563.000000   S1L [5]:131115180.000000   
    S1R [0]:14353382.000000   S1R [1]:120899850.000000   S1R [2]:112896800.000000   
    S1R [3]:98569728.000000   S1R [4]:212189730.000000   S1R [5]:54226489.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:5.097E+05      S2  [1]:6.023E+05      S2  [2]:8.932E+05      S2  [3]:1.448E+06      
    S2  [4]:1.92E+06       S2  [5]:2.086E+06      S2  [6]:1.944E+06      S2  [7]:2.067E+06      
    S2  [8]:2.02E+06       S2  [9]:1.928E+06      S2  [10]:1.969E+06      S2  [11]:2.023E+06      
    S2  [12]:2.719E+06      S2  [13]:1.744E+06      S2  [14]:1.193E+06      S2  [15]:8.698E+05      
    S2  [16]:5.087E+05      S2  [17]:7.195E+05      S2  [18]:1.117E+06      S2  [19]:1.43E+06       
    S2  [20]:1.921E+06      S2  [21]:2.038E+06      S2  [22]:1.993E+06      S2  [23]:2.309E+06      
    S2  [24]:1.947E+06      S2  [25]:2.031E+06      S2  [26]:1.863E+06      S2  [27]:1.822E+06      
    S2  [28]:1.684E+06      S2  [29]:1.471E+06      S2  [30]:1.369E+06      S2  [31]:8.181E+05      
    
    Right arm S2 scintillators rates
    S2  [0]:667.0 Hz   S2  [1]:788.3 Hz   S2  [2]:1168.9 Hz   S2  [3]:1895.4 Hz   
    S2  [4]:2512.3 Hz   S2  [5]:2729.9 Hz   S2  [6]:2544.3 Hz   S2  [7]:2705.8 Hz   
    S2  [8]:2643.3 Hz   S2  [9]:2523.5 Hz   S2  [10]:2576.9 Hz   S2  [11]:2647.6 Hz   
    S2  [12]:3559.1 Hz   S2  [13]:2282.0 Hz   S2  [14]:1561.3 Hz   S2  [15]:1138.3 Hz   
    S2  [16]:665.7 Hz   S2  [17]:941.6 Hz   S2  [18]:1462.3 Hz   S2  [19]:1871.2 Hz   
    S2  [20]:2514.7 Hz   S2  [21]:2667.7 Hz   S2  [22]:2608.8 Hz   S2  [23]:3022.3 Hz   
    S2  [24]:2547.6 Hz   S2  [25]:2657.5 Hz   S2  [26]:2438.7 Hz   S2  [27]:2385.1 Hz   
    S2  [28]:2203.3 Hz   S2  [29]:1924.5 Hz   S2  [30]:1792.0 Hz   S2  [31]:1070.6 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:163523310.000000   S2  [ 1]:193249750.000000   S2  [ 2]:286573840.000000   
    S2  [ 3]:464676420.000000   S2  [ 4]:615929010.000000   S2  [ 5]:669261280.000000   
    S2  [ 6]:623772270.000000   S2  [ 7]:663349880.000000   S2  [ 8]:648040030.000000   
    S2  [ 9]:618670380.000000   S2  [10]:631755430.000000   S2  [11]:649079920.000000   
    S2  [12]:872557920.000000   S2  [13]:559469060.000000   S2  [14]:382769900.000000   
    S2  [15]:279079350.000000   S2  [16]:163205030.000000   S2  [17]:230844800.000000   
    S2  [18]:358493800.000000   S2  [19]:458741270.000000   S2  [20]:616502050.000000   
    S2  [21]:654028120.000000   S2  [22]:639575270.000000   S2  [23]:740942840.000000   
    S2  [24]:624567990.000000   S2  [25]:651509740.000000   S2  [26]:597867840.000000   
    S2  [27]:584733390.000000   S2  [28]:540167470.000000   S2  [29]:471821510.000000   
    S2  [30]:439319040.000000   S2  [31]:262478390.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 142096260.000000   
    Right arm S2m  : 511142380.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:5.831E+05      S1R [1]:8.386E+05      S1R [2]:7.955E+05      
    S1R [3]:5.832E+05      S1R [4]:6.097E+05      S1R [5]:4.755E+05      
    S1L [0]:5.499E+05      S1L [1]:7.759E+05      S1L [2]:7.29E+05       
    S1L [3]:6.308E+05      S1L [4]:6.197E+05      S1L [5]:5.024E+05      
    
    
    Left arm S1 scintillators rates
    S1R [0]:763.1 Hz   S1R [1]:1097.5 Hz   S1R [2]:1041.0 Hz   
    S1R [3]:763.3 Hz   S1R [4]:798.0 Hz   S1R [5]:622.3 Hz   
    S1L [0]:719.7 Hz   S1L [1]:1015.5 Hz   S1L [2]:954.1 Hz   
    S1L [3]:825.5 Hz   S1L [4]:811.0 Hz   S1L [5]:657.5 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:187092890.0    S1R [1]:269062300.0    S1R [2]:255225810.0    
    S1R [3]:187121770.0    S1R [4]:195638500.0    S1R [5]:152569690.0    
    S1L [0]:176447610.0    S1L [1]:248964680.0    S1L [2]:233899000.0    
    S1L [3]:202390220.0    S1L [4]:198832920.0    S1L [5]:161183970.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.195E+06      S2R [1]:1.288E+06      S2R [2]:1.435E+06      
    S2R [3]:2.098E+06      S2R [4]:1.92E+06       S2R [5]:1.416E+06      
    S2L [0]:2.211E+06      S2L [1]:1.363E+06      S2L [2]:1.655E+06      
    S2L [3]:1.254E+06      S2L [4]:1.288E+06      S2L [5]:1.561E+06      
    
    
    Left arm S2 scintillators rates
    S2R [0]:1563.8 Hz   S2R [1]:1685.1 Hz   S2R [2]:1877.5 Hz   
    S2R [3]:2745.6 Hz   S2R [4]:2513.1 Hz   S2R [5]:1852.7 Hz   
    S2L [0]:2893.6 Hz   S2L [1]:1783.2 Hz   S2L [2]:2166.1 Hz   
    S2L [3]:1641.7 Hz   S2L [4]:1685.9 Hz   S2L [5]:2043.0 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:383393960.0    S2R [1]:413112690.0    S2R [2]:460302220.0    
    S2R [3]:673117620.0    S2R [4]:616112220.0    S2R [5]:454210500.0    
    S2L [0]:709405190.0    S2L [1]:437178950.0    S2L [2]:531047210.0    
    S2L [3]:402481530.0    S2L [4]:413320930.0    S2L [5]:500870300.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.981E+06      GasC  [1]:1.492E+06      GasC  [2]:1.802E+06      
    GasC  [3]:1.961E+06      GasC  [4]:1.894E+06      GasC  [5]:1.655E+06      
    GasC  [6]:1.576E+06      GasC  [7]:1.643E+06      GasC  [8]:1.466E+06      
    GasC  [9]:1.088E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:2592.3 Hz   GasC  [1]:1952.9 Hz   GasC  [2]:2358.5 Hz   
    GasC  [3]:2566.4 Hz   GasC  [4]:2479.0 Hz   GasC  [5]:2166.1 Hz   
    GasC  [6]:2062.5 Hz   GasC  [7]:2150.6 Hz   GasC  [8]:1918.6 Hz   
    GasC  [9]:14244.8 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:635524500.0 GasC  [1]:478774400.0 GasC  [2]:578216530.0 
    GasC  [3]:629192130.0 GasC  [4]:607764890.0 GasC  [5]:531057160.0 
    GasC  [6]:505649410.0 GasC  [7]:527256650.0 GasC  [8]:470365150.0 
    GasC  [9]:3492284800.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  205702450.000000   
    Left S2 :   499546100.000000   
    Gas Cerenkov :  845608570.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3925 at Thu May 31 03:12:52 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.015
    Left Arm arm angle : 20.851
    Right Arm D1 momentum : 0.592
    Right Arm arm angle : 63.0391
    HALLA:p : 2094.09
    HALLA:dpp : -1.63295e-05
    Tiefenbach Hall A energy : 2094.09
    Left Arm Top VDC Current : -1.02539
    Left Arm Bottom VDC Current : -0.830078
    Left Arm Q1 momentum : 2.01507
    Left Arm Q1 power supply : 1516
    Left Arm Q1 gauss meter : -0.12782
    Left Arm Q2 gauss meter : 0.4574
    Left Arm Q2 power supply current : 867.473
    Left Arm Q2 momentum : 2.01457
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 681.929
    Left Arm D1 momentum : 2.015
    Left Arm D1 NMR : 0.745618
    Left Arm Q3 gauss meter : -0.4007
    Left Arm Q3 power supply current : 802.211
    Left Arm Q3 momentum : 2.015
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.591998
    Right Arm Q1 power supply : 445.144
    Right Arm Q1 gauss meter : 0.011277
    Right Arm Q2 power supply current : 254.88
    Right Arm Q2 momentum : 0.592239
    Right Arm Q2 gauss meter : -0.13492
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 203.38
    Right Arm D1 momentum : 0.591998
    Right Arm D1 NMR : 0.219683
    Right Arm Q3 power supply current : 235.533
    Right Arm Q3 momentum : 0.591926
    Right Arm Q3 gauss meter : -0.10627
    Right Arm Q3 power supply polarity : enabled