Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 03:23:37 on May 31, 2007

    Entry number 203787

    keyword=End_of_Run_3926
    ****************************
     Run Number: 3926
     End of Run Comment:
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=2.094
    beam_raster=on
    leftarm_p=2.015
    leftarm_theta=20.851
    leftarm_colli=6msrd
    rightarm_p=0.5920
    rightarm_theta=63.039
    rightarm_colli=out
    comment_text=5 uA
     
    
    PRESCALE FACTORS:ps1=99999   ps2=99999   ps3=1   ps4=10   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 578512       [+]: 6195         [-]: 5064         
    TIME  [0]: 9.994 mins  [+]: 0.107 mins  [-]: 0.090 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       587.62665 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  85.94%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/1659.6 Hz   T2[0] : 0.3/29724.3 Hz   T3[0] :1116.5/1116.5 Hz   T4[0] : 5.9/58.6 Hz   
    T5[0] : 0.0/4.3  Hz   T6[0] : 0.0/10.6 Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 0.0/1699.8 Hz   T2[+] : 0.2/30072.4 Hz   T3[+] :1121.0/1121.0 Hz   T4[+] : 5.9/60.8 Hz   
    T5[+] : 0.0/3.1  Hz   T6[+] : 0.0/10.3 Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 0.0/1607.2 Hz   T2[-] : 0.2/29048.3 Hz   T3[-] :1083.8/1083.8 Hz   T4[-] : 6.3/64.5 Hz   
    T5[-] : 0.0/5.2  Hz   T6[-] : 0.0/12.8 Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      9/995118   T2[0] :    178/17823094  T3[0] : 669489/669489   T4[0] :   3513/35134    
    T5[0] :      0/2576     T6[0] :      0/6370     T7[0] :      0/23       T8[0] :      9/614005   
    
    T1[+] :      0/10878    T2[+] :      1/192446   T3[+] :   7174/7174     T4[+] :     38/389      
    T5[+] :      0/20       T6[+] :      0/66       T7[+] :      0/0        T8[+] :      0/6553     
    
    T1[-] :      0/8678     T2[-] :      1/156844   T3[-] :   5852/5852     T4[-] :     34/348      
    T5[-] :      0/28       T6[-] :      0/69       T7[-] :      0/0        T8[-] :      0/5529     
    
    
    AVERAGE CURRENT
    BCM x1 : 4.6519 uA  BCM x3 : 4.5720 uA  BCM x10: 4.7990 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :1.743E+04 ppm     BCM u3 :1.823E+04 ppm     BCM u10:1.629E+04 ppm     
    BCM d1 :1.614E+04 ppm     BCM d3 :1.615E+04 ppm     BCM d10:1.602E+04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002705       BCM u3 [0]:0.002607       BCM u10[0]:0.002882       
    BCM u1 [+]:2.931E-05      BCM u3 [+]:2.827E-05      BCM u10[+]:3.038E-05      
    BCM u1 [-]:2.388E-05      BCM u3 [-]:2.3E-05        BCM u10[-]:2.481E-05      
    
    BCM d1 [0]:0.002874       BCM d3 [0]:0.002875       BCM d10[0]:0.002873       
    BCM d1 [+]:3.11E-05       BCM d3 [+]:3.112E-05      BCM d10[+]:3.108E-05      
    BCM d1 [-]:2.541E-05      BCM d3 [-]:2.542E-05      BCM d10[-]:2.54E-05       
    
    
    
    
    Right S1 scintillators
    S1R [0]:3.873E+04      S1R [1]:3.267E+05      S1R [2]:3.029E+05      
    S1R [3]:2.646E+05      S1R [4]:5.694E+05      S1R [5]:1.458E+05      
    
    
    Right S1 scintillators rates 
    S1L [0]:66.5 Hz   S1L [1]:2915.9 Hz   S1L [2]:492.6 Hz   
    S1L [3]:447.1 Hz   S1L [4]:381.4 Hz   S1L [5]:592.7 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:14747099.000000   S1L [1]:646406760.000000   S1L [2]:109195010.000000   
    S1L [3]:99118121.000000   S1L [4]:84552181.000000   S1L [5]:131382580.000000   
    S1R [0]:14320081.000000   S1R [1]:120781070.000000   S1R [2]:111968960.000000   
    S1R [3]:97823387.000000   S1R [4]:210498870.000000   S1R [5]:53906327.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:4.331E+05      S2  [1]:5.153E+05      S2  [2]:7.658E+05      S2  [3]:1.247E+06      
    S2  [4]:1.654E+06      S2  [5]:1.799E+06      S2  [6]:1.677E+06      S2  [7]:1.778E+06      
    S2  [8]:1.741E+06      S2  [9]:1.664E+06      S2  [10]:1.698E+06      S2  [11]:1.74E+06       
    S2  [12]:2.343E+06      S2  [13]:1.499E+06      S2  [14]:1.026E+06      S2  [15]:7.45E+05       
    S2  [16]:4.324E+05      S2  [17]:6.15E+05       S2  [18]:9.547E+05      S2  [19]:1.23E+06       
    S2  [20]:1.655E+06      S2  [21]:1.756E+06      S2  [22]:1.718E+06      S2  [23]:1.997E+06      
    S2  [24]:1.677E+06      S2  [25]:1.751E+06      S2  [26]:1.607E+06      S2  [27]:1.568E+06      
    S2  [28]:1.451E+06      S2  [29]:1.267E+06      S2  [30]:1.175E+06      S2  [31]:7.015E+05      
    
    Right arm S2 scintillators rates
    S2  [0]:722.3 Hz   S2  [1]:859.4 Hz   S2  [2]:1277.2 Hz   S2  [3]:2079.0 Hz   
    S2  [4]:2759.1 Hz   S2  [5]:2999.6 Hz   S2  [6]:2796.6 Hz   S2  [7]:2965.1 Hz   
    S2  [8]:2902.8 Hz   S2  [9]:2774.4 Hz   S2  [10]:2831.5 Hz   S2  [11]:2901.2 Hz   
    S2  [12]:3907.8 Hz   S2  [13]:2500.8 Hz   S2  [14]:1711.3 Hz   S2  [15]:1242.4 Hz   
    S2  [16]:721.2 Hz   S2  [17]:1025.7 Hz   S2  [18]:1592.2 Hz   S2  [19]:2051.2 Hz   
    S2  [20]:2759.6 Hz   S2  [21]:2928.9 Hz   S2  [22]:2865.9 Hz   S2  [23]:3330.3 Hz   
    S2  [24]:2797.4 Hz   S2  [25]:2920.5 Hz   S2  [26]:2680.7 Hz   S2  [27]:2614.4 Hz   
    S2  [28]:2419.4 Hz   S2  [29]:2113.4 Hz   S2  [30]:1959.6 Hz   S2  [31]:1169.9 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:160118490.000000   S2  [ 1]:190508510.000000   S2  [ 2]:283138910.000000   
    S2  [ 3]:460879390.000000   S2  [ 4]:611653030.000000   S2  [ 5]:664955980.000000   
    S2  [ 6]:619959360.000000   S2  [ 7]:657309580.000000   S2  [ 8]:643507840.000000   
    S2  [ 9]:615039960.000000   S2  [10]:627702620.000000   S2  [11]:643161050.000000   
    S2  [12]:866305940.000000   S2  [13]:554381200.000000   S2  [14]:379363660.000000   
    S2  [15]:275418940.000000   S2  [16]:159873740.000000   S2  [17]:227374040.000000   
    S2  [18]:352959890.000000   S2  [19]:454720350.000000   S2  [20]:611758390.000000   
    S2  [21]:649290150.000000   S2  [22]:635337930.000000   S2  [23]:738275920.000000   
    S2  [24]:620143850.000000   S2  [25]:647437150.000000   S2  [26]:594276530.000000   
    S2  [27]:579567510.000000   S2  [28]:536337380.000000   S2  [29]:468512480.000000   
    S2  [30]:434407220.000000   S2  [31]:259355660.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 141225040.000000   
    Right arm S2m  : 506969780.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:4.883E+05      S1R [1]:7.125E+05      S1R [2]:6.761E+05      
    S1R [3]:4.921E+05      S1R [4]:5.186E+05      S1R [5]:4.027E+05      
    S1L [0]:4.626E+05      S1L [1]:6.569E+05      S1L [2]:6.178E+05      
    S1L [3]:5.318E+05      S1L [4]:5.247E+05      S1L [5]:4.24E+05       
    
    
    Left arm S1 scintillators rates
    S1R [0]:814.4 Hz   S1R [1]:1188.2 Hz   S1R [2]:1127.6 Hz   
    S1R [3]:820.6 Hz   S1R [4]:864.8 Hz   S1R [5]:671.5 Hz   
    S1L [0]:771.4 Hz   S1L [1]:1095.5 Hz   S1L [2]:1030.4 Hz   
    S1L [3]:886.9 Hz   S1L [4]:875.1 Hz   S1L [5]:707.1 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:180545120.0    S1R [1]:263404020.0    S1R [2]:249967180.0    
    S1R [3]:181917490.0    S1R [4]:191720060.0    S1R [5]:148866290.0    
    S1L [0]:171012820.0    S1L [1]:242866850.0    S1L [2]:228425130.0    
    S1L [3]:196622080.0    S1L [4]:194002290.0    S1L [5]:156748190.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.004E+06      S2R [1]:1.089E+06      S2R [2]:1.225E+06      
    S2R [3]:1.775E+06      S2R [4]:1.627E+06      S2R [5]:1.194E+06      
    S2L [0]:1.86E+06       S2L [1]:1.159E+06      S2L [2]:1.41E+06       
    S2L [3]:1.065E+06      S2L [4]:1.092E+06      S2L [5]:1.307E+06      
    
    
    Left arm S2 scintillators rates
    S2R [0]:1675.1 Hz   S2R [1]:1815.8 Hz   S2R [2]:2043.6 Hz   
    S2R [3]:2960.1 Hz   S2R [4]:2713.7 Hz   S2R [5]:1991.1 Hz   
    S2L [0]:3102.4 Hz   S2L [1]:1933.4 Hz   S2L [2]:2350.9 Hz   
    S2L [3]:1776.5 Hz   S2L [4]:1821.6 Hz   S2L [5]:2180.0 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:371351250.0    S2R [1]:402535030.0    S2R [2]:453029280.0    
    S2R [3]:656216340.0    S2R [4]:601593880.0    S2R [5]:441391830.0    
    S2L [0]:687749880.0    S2L [1]:428596450.0    S2L [2]:521165110.0    
    S2L [3]:393825340.0    S2L [4]:403821630.0    S2L [5]:483283240.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.622E+06      GasC  [1]:1.226E+06      GasC  [2]:1.477E+06      
    GasC  [3]:1.615E+06      GasC  [4]:1.549E+06      GasC  [5]:1.359E+06      
    GasC  [6]:1.281E+06      GasC  [7]:1.33E+06       GasC  [8]:1.186E+06      
    GasC  [9]:8.956E+06      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:2705.5 Hz   GasC  [1]:2045.1 Hz   GasC  [2]:2463.6 Hz   
    GasC  [3]:2693.9 Hz   GasC  [4]:2583.4 Hz   GasC  [5]:2265.8 Hz   
    GasC  [6]:2135.8 Hz   GasC  [7]:2218.3 Hz   GasC  [8]:1977.3 Hz   
    GasC  [9]:14936.1 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:599771940.0 GasC  [1]:453376440.0 GasC  [2]:546135500.0 
    GasC  [3]:597198370.0 GasC  [4]:572700470.0 GasC  [5]:502297190.0 
    GasC  [6]:473464780.0 GasC  [7]:491757790.0 GasC  [8]:438346880.0 
    GasC  [9]:3311111600.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  200508120.000000   
    Left S2 :   487046610.000000   
    Gas Cerenkov :  798616110.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3926 at Thu May 31 03:23:35 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.015
    Left Arm arm angle : 20.851
    Right Arm D1 momentum : 0.592001
    Right Arm arm angle : 63.0391
    HALLA:p : 2094.07
    HALLA:dpp : -2.94429e-05
    Tiefenbach Hall A energy : 2094.07
    Left Arm Top VDC Current : -1.31836
    Left Arm Bottom VDC Current : -1.61133
    Left Arm Q1 momentum : 2.01507
    Left Arm Q1 power supply : 1515.95
    Left Arm Q1 gauss meter : -0.12783
    Left Arm Q2 gauss meter : 0.4574
    Left Arm Q2 power supply current : 867.635
    Left Arm Q2 momentum : 2.01494
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 681.924
    Left Arm D1 momentum : 2.015
    Left Arm D1 NMR : 0.745618
    Left Arm Q3 gauss meter : -0.4007
    Left Arm Q3 power supply current : 802.19
    Left Arm Q3 momentum : 2.01495
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.591998
    Right Arm Q1 power supply : 445.144
    Right Arm Q1 gauss meter : 0.011288
    Right Arm Q2 power supply current : 254.782
    Right Arm Q2 momentum : 0.59201
    Right Arm Q2 gauss meter : -0.1349
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 203.388
    Right Arm D1 momentum : 0.592001
    Right Arm D1 NMR : 0.219684
    Right Arm Q3 power supply current : 235.551
    Right Arm Q3 momentum : 0.591974
    Right Arm Q3 gauss meter : -0.10628
    Right Arm Q3 power supply polarity : enabled