    keyword=Start_Run_3927,Run_type=4He Production,target_type=4He 20cm,target_colli=out,beam_e0=2.094,beam_raster=on,leftarm_p=1.867,leftarm_theta=36.099,leftarm_colli=out,rightarm_p=0.5920,rightarm_theta=63.039,rightarm_colli=out,comment_text=50 uA
    Run Timestamp:       Thu May 31 03:58:26 EDT 2007
    Beginning-of-run EPICS data for Run Number 3927 at Thu May 31 03:59:16 EDT 2007
    
    
    
    Run_type=4He Production
    target_type=4He 20cm
    target_colli=out
    beam_e0=2.094
    beam_raster=on
    leftarm_p=1.867
    leftarm_theta=36.099
    leftarm_colli=out
    rightarm_p=0.5920
    rightarm_theta=63.039
    rightarm_colli=out
    comment_text=50 uA
    
    
    ; Spectrometer DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = Right arm trigger 
    ; T2 = Right arm efficiency trigger 
    ; T3 = Left arm trigger.
    ; T4 = Left arm efficiency trigger
    ; T5 = T1.and.T3 (main coincidence trigger)
    ; T6 = T3.and.R-arm-retiming 
    ; T7 = T1.and.T4
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return.
    
    ps1=1670,ps2=60000,ps3=1,ps4=10,ps5=1,ps6=1,ps7=1,ps8=65535
    
    
    
    
    Left Arm Q1 momentum : 1.86706
    Left Arm Q1 power supply : 1404.65
    Left Arm Q1 gauss meter : -0.11848
    Left Arm Q2 power supply current : 803.947
    Left Arm Q2 momentum : 1.86704
    Left Arm Q2 gauss meter : 0.424
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 628.404
    Left Arm D1 momentum : 1.86699
    Left Arm D1 NMR : 0.690881
    Left Arm Q3 power supply current : 743.323
    Left Arm Q3 momentum : 1.86709
    Left Arm Q3 gauss meter : -0.3713
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -0.6704
    Right Arm Q1 momentum : 0.591998
    Right Arm Q1 power supply : 445.144
    Right Arm Q1 gauss meter : 0.011286
    Right Arm Q2 power supply current : 254.791
    Right Arm Q2 momentum : 0.592032
    Right Arm Q2 gauss meter : -0.13492
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 203.38
    Right Arm D1 momentum : 0.592002
    Right Arm D1 NMR : 0.219685
    Right Arm Q3 power supply current : 235.548
    Right Arm Q3 momentum : 0.591965
    Right Arm Q3 gauss meter : -0.10629
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : 0.21729
    Left Arm Top VDC Current : 0.390625
    Left Arm Bottom VDC Current : -1.36719
    Left Arm Top VDC voltage : 3.98584
    Left Arm Bottom VDC voltage : 4.00146
    Right Arm Top VDC voltage : 3.5957
    Right Arm Bottom VDC voltage : 3.6001
    -----
    Average current of the two cavities : 49.7163
    Current on Unser monitor : 46.4595
    Current on Upstream bcm : 50.2551
    Current on Downstream bcm : 49.1776
    Upstream Cavity Coefficient : 43.47
    Downstream Cavity Coefficient : 42.89
    Current on IBC0L02 (source) : 103.123
    Hall C Current : 53.7503
    Hall A momentum (Tiefenbach) (HALLA:p) : 2094.08
    Hall A momentum orbit correction (dpp) : -2.31836e-05
    Hall A setup momentum (MMSHLAE) : 2097.38
    Hall A energy (halla_MeV) : 2094.08
    Hall C energy (hallc_MeV) : 3114.28
    Delta(E)/E width (MV_AI_DXWID) : 0.83809
    MBSY1c magnet current (amp) : 87.2286
    MBSY1c Bdl : 523175
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.182129
    HacL_HPE1313A:0_Ch55 : 24.0723
    HacL_HPE1313A:0_Ch54 : -0.248047
    Left Arm Angle Floor Angle : 36.5
    Left Arm Angle Vernier : -38.5
    Left Arm Scattering Angle : 36.0991
    Right Arm Arm Collimator : 0.863232
    HacR_HPE1313A:0_Ch58 : -0.563965
    HacR_HPE1313A:0_Ch55 : 22.0703
    HacR_HPE1313A:0_Ch54 : -0.942383
    Right Arm Angle Floor Angle : 63
    Right Arm Angle Vernier : -27.4
    Right Arm Scattering Angle : 63.0391
    -----
    IPM1C12.XPOS : 0.0111069
    IPM1C12.YPOS : 0.0418152
    IPM1H04A.XPOS : -4.51191
    IPM1H04A.YPOS : 2.0273
    IPM1H04B.XPOS : -4.50275
    IPM1H04B.YPOS : 1.98919
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 235
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 8500
    Beam Half-wave plate (off=out) : OUT
    Arc OTR x-position : -1.91418
    Arc OTR y-position : -1.29772
    Arc OTR x-width : 2.85274
    Arc OTR y-width : 2.14764
    Arc OTR data valid flag : No
    Arc OTR In/Out : Sources bin crl doc lib ped tcl tcp tir tmp vme
    -----
    Target : Loop1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 2 : 35
    Encoder position : 3.30505e+07
    Target type : 3.30505e+07
    temperature loop 1(1) : 7.03
    temperature loop 1(2) : 7
    temperature loop 1(3) : 7.28
    Heat exchange He : 150.8
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 120.47
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 254.3
    pressure loop He : 203.986
    pressure loop H2 before : 25.6336
    pressure loop H2 return : 25.803
    HPH He loop : 56.654
    Fan speed He loop : 60
    HPH H2 loop : 0.011068
    Fan speed H2 loop : 0
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.13168
    SLI vert. size mm : 0
    SLI y position : 2.89202
    MF7b1461_0ch0property.F : -2340.4
    MF7b1461_0ch1property.F : -2132.7
    MF7b1461_0ch2property.F : -2223.5
    MF7b1461_0ch3property.F : -2181.2
    MF7b1461_0ch4property.F : -2400.7
    MF7b1461_0ch5property.F : -2096.7
    MF7b1461_0ch6property.F : -1907.1
    MF7b1461_0ch7property.F : -1836.9
    MF7b1461_0ch8property.F : -2004
    MF7b1461_0ch9property.F : -1909.3
    MF7b1461_0ch10property.F : -2086.2
    MF7b1461_0ch11property.F : -1887
    MF7b1461_1ch0property.F : -1718.6
    MF7b1461_1ch1property.F : -1649.2
    MF7b1461_1ch2property.F : -1790.1
    MF7b1461_1ch3property.F : -1643.2
    MF7b1461_1ch4property.F : -1993.7
    MF7b1461_1ch5property.F : -1750.3
    MF7b1461_1ch6property.F : -2098.4
    MF7b1461_1ch7property.F : -2059.9
    MF7b1461_1ch8property.F : -2182.2
    MF7b1461_1ch9property.F : -1939
    MF7b1461_1ch10property.F : -1856.2
    MF7b1461_1ch11property.F : -2012.7
    MF7b1461_2ch0property.F : -1616.9
    MF7b1461_2ch1property.F : -1599.3
    MF7b1461_2ch2property.F : -1515
    MF7b1461_2ch3property.F : -1467.4
    MF7b1461_2ch4property.F : -1852.1
    MF7b1461_2ch5property.F : -1952.1
    MF7b1461_2ch6property.F : -1802.1
    MF7b1461_2ch7property.F : -1799.6
    MF7b1461_2ch8property.F : -1961.6
    MF7b1461_2ch9property.F : -1898
    MF7b1461_2ch10property.F : -18.8
    MF7b1461_2ch11property.F : -22.8
    MF7b1461_3ch0property.F : -860.4
    MF7b1461_3ch1property.F : -784.5
    MF7b1461_3ch2property.F : -905.8
    MF7b1461_3ch3property.F : -980.5
    MF7b1461_3ch4property.F : -760.2
    MF7b1461_3ch5property.F : -860.9
    MF7b1461_3ch6property.F : -1081.3
    MF7b1461_3ch7property.F : -990.8
    MF7b1461_3ch8property.F : -811.2
    MF7b1461_3ch9property.F : -790.9
    MF7b1461_3ch10property.F : -860
    MF7b1461_3ch11property.F : -785.3
    MF7b1461_4ch0property.F : -870.1
    MF7b1461_4ch1property.F : -901.3
    MF7b1461_4ch2property.F : -750.8
    MF7b1461_4ch3property.F : -895.1
    MF7b1461_4ch4property.F : -921.7
    MF7b1461_4ch5property.F : -821.2
    MF7b1461_4ch6property.F : -810.4
    MF7b1461_4ch7property.F : -801.1
    MF7b1461_4ch8property.F : -1160.4
    MF7b1461_4ch9property.F : -991.4
    MF7b1461_4ch10property.F : -1030.9
    MF7b1461_4ch11property.F : -836.3
    MF7b1461_5ch0property.F : -1041.1
    MF7b1461_5ch1property.F : -871
    MF7b1461_5ch2property.F : -916.2
    MF7b1461_5ch3property.F : -735.8
    MF7b1461_5ch4property.F : -890.7
    MF7b1461_5ch5property.F : -810.3
    MF7b1461_5ch6property.F : -821.1
    MF7b1461_5ch7property.F : -870.3
    MF7b1461_5ch8property.F : -741.3
    MF7b1461_5ch9property.F : -840.6
    MF7b1461_5ch10property.F : -16.5
    MF7b1461_5ch11property.F : -25.6
    MF7b1461_9ch0property.F : -921.4
    MF7b1461_9ch1property.F : -881.5
    MF7b1461_9ch2property.F : -798.8
    MF7b1461_9ch3property.F : -870.2
    MF7b1461_9ch4property.F : -810.5
    MF7b1461_9ch5property.F : -941.2
    MF7b1461_9ch6property.F : -850.1
    MF7b1461_9ch7property.F : -889.8
    MF7b1461_9ch8property.F : -810.4
    MF7b1461_9ch9property.F : -780.3
    MF7b1461_9ch10property.F : -820.4
    MF7b1461_9ch11property.F : -850.3
    MF7b1461_10ch0property.F : -755.7
    MF7b1461_10ch1property.F : -812.4
    MF7b1461_10ch2property.F : -871
    MF7b1461_10ch3property.F : -900.8
    MF7b1461_10ch4property.F : -881.4
    MF7b1461_10ch5property.F : -871
    MF7b1461_10ch6property.F : -815.2
    MF7b1461_10ch7property.F : -824.8
    MF7b1461_10ch8property.F : -760.3
    MF7b1461_10ch9property.F : -715.7
    MF7b1461_10ch10property.F : -911
    MF7b1461_10ch11property.F : -781.3
    MF7b1461_11ch0property.F : -1000.7
    MF7b1461_11ch1property.F : -900.4
    MF7b1461_11ch2property.F : -850.6
    MF7b1461_11ch3property.F : -1079.9
    MF7b1461_11ch4property.F : -1050.2
    MF7b1461_11ch5property.F : -800
    MF7b1461_11ch6property.F : -860.4
    MF7b1461_11ch7property.F : -1030.5
    MF7b1461_11ch8property.F : -911.3
    MF7b1461_11ch9property.F : -881.1
    MF7b1461_11ch10property.F : -12.9
    MF7b1461_11ch11property.F : -25.5
    MF3b1461_1ch0property.F : -1978.8
    MF3b1461_1ch1property.F : -1889.3
    MF3b1461_1ch2property.F : -1986.4
    MF3b1461_1ch3property.F : -2000.5
    MF3b1461_1ch4property.F : -1770.7
    MF3b1461_1ch5property.F : -1627.6
    MF3b1461_1ch6property.F : -1970.2
    MF3b1461_1ch7property.F : -1800.6
    MF3b1461_1ch8property.F : -1846.2
    MF3b1461_1ch9property.F : -1806.8
    MF3b1461_1ch10property.F : -1859.1
    MF3b1461_1ch11property.F : -1804.7
    MF3b1461_10ch0property.F : -1785.8
    MF3b1461_10ch1property.F : -1896.5
    MF3b1461_10ch2property.F : -2003.5
    MF3b1461_10ch3property.F : -1890.8
    MF3b1461_10ch4property.F : -1999.4
    MF3b1461_10ch5property.F : -1896.9
    MF3b1461_10ch6property.F : -1968.8
    MF3b1461_10ch7property.F : -1789.4
    MF3b1461_10ch8property.F : -1978.9
    MF3b1461_10ch9property.F : -1968.8
    MF3b1461_10ch10property.F : -17.2
    MF3b1461_10ch11property.F : -19.1
    MF3b1461_11ch0property.F : -1791.5
    MF3b1461_11ch1property.F : -1807.8
    MF3b1461_11ch2property.F : -2001.1
    MF3b1461_11ch3property.F : -1872
    MF3b1461_11ch4property.F : -1890.7
    MF3b1461_11ch5property.F : -1679.3
    MF3b1461_11ch6property.F : -1804.6
    MF3b1461_11ch7property.F : -1778.9
    MF3b1461_11ch8property.F : -1731
    MF3b1461_11ch9property.F : -1899.8
    MF3b1461_11ch10property.F : -17.4
    MF3b1461_11ch11property.F : -21.5
    MF3b1461_14ch0property.F : -19.3
    MF3b1461_14ch1property.F : -21
    MF3b1461_14ch2property.F : -18.8
    MF3b1461_14ch3property.F : -18.9
    MF3b1461_14ch4property.F : -16.6
    MF3b1461_14ch5property.F : -16.7
    MF3b1461_14ch6property.F : -18.8
    MF3b1461_14ch7property.F : -19.2
    MF3b1461_14ch8property.F : -20.4
    MF3b1461_14ch9property.F : -17.7
    MF3b1461_14ch10property.F : -20.3
    MF3b1461_14ch11property.F : -26.9
    LVDT Position Ch1 : -936
    LVDT Position Ch2 : 1327
    LVDT Position Ch2 : 675
    L_VMIC1182 for iocha18 : 215606
    RVDT Position Ch1 : -7040
    RVDT Position Ch2 : -1713
    RVDT Position Ch2 : 3058
    R_VMIC1182 for iocha19 : 100436