keyword=End_of_Run_3928
****************************
Run Number: 3928
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=1.867
leftarm_theta=36.099
leftarm_colli=out
rightarm_p=0.5920
rightarm_theta=63.039
rightarm_colli=out
comment_text=50 uA
PRESCALE FACTORS:ps1=1670 ps2=55000 ps3=1 ps4=90 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 977750 [+]: 9788 [-]: 9501
TIME [0]: 49.002 mins [+]: 0.499 mins [-]: 0.466 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 2881.25580 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 93.82%
TRIGGER RATES: PRES/REAL
T1[0] : 7.0/11707.6 Hz T2[0] : 3.5/193586.1 Hz T3[0] :338.7/338.7 Hz T4[0] : 3.8/337.8 Hz
T5[0] : 4.7/4.7 Hz T6[0] :20.4/20.4 Hz T7[0] : 1.5/1.5 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 6.9/11520.1 Hz T2[+] : 3.4/190865.7 Hz T3[+] :331.1/331.1 Hz T4[+] : 3.7/331.4 Hz
T5[+] : 5.0/5.0 Hz T6[+] :19.6/19.6 Hz T7[+] : 1.5/1.5 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 7.1/11913.0 Hz T2[-] : 3.5/196525.1 Hz T3[-] :345.7/345.7 Hz T4[-] : 3.9/348.8 Hz
T5[-] : 4.3/4.3 Hz T6[-] :19.9/19.9 Hz T7[-] : 1.7/1.7 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 20611/34421573 T2[0] : 10348/569164447 T3[0] : 995693/995693 T4[0] : 11036/993262
T5[0] : 13747/13747 T6[0] : 59976/59976 T7[0] : 4549/4549 T8[0] : 45/3010673
T1[+] : 206/344963 T2[+] : 103/5715346 T3[+] : 9915/9915 T4[+] : 110/9923
T5[+] : 150/150 T6[+] : 586/586 T7[+] : 45/45 T8[+] : 0/30663
T1[-] : 199/333367 T2[-] : 99/5499441 T3[-] : 9674/9674 T4[-] : 108/9762
T5[-] : 121/121 T6[-] : 556/556 T7[-] : 47/47 T8[-] : 0/28655
AVERAGE CURRENT
BCM x1 : 35.3566uA BCM x3 : 35.3269uA BCM x10: 13.1205uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-1.509E+04 ppm BCM u3 :-1.517E+04 ppm BCM u10:-1.244E+04 ppm
BCM d1 :-1.492E+04 ppm BCM d3 :-1.491E+04 ppm BCM d10:-1.438E+04 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1044 BCM u3 [0]:0.1045 BCM u10[0]:-0.01122
BCM u1 [+]:0.001047 BCM u3 [+]:0.001049 BCM u10[+]:0.0008151
BCM u1 [-]:0.001009 BCM u3 [-]:0.00101 BCM u10[-]:0.0007809
BCM d1 [0]:0.1035 BCM d3 [0]:0.1032 BCM d10[0]:0.08837
BCM d1 [+]:0.001039 BCM d3 [+]:0.001036 BCM d10[+]:0.0008874
BCM d1 [-]:0.001001 BCM d3 [-]:0.0009976 BCM d10[-]:0.0008535
Right S1 scintillators
S1R [0]:1.294E+06 S1R [1]:1.136E+07 S1R [2]:1.014E+07
S1R [3]:8.949E+06 S1R [4]:1.891E+07 S1R [5]:5.114E+06
Right S1 scintillators rates
S1L [0]:458.8 Hz S1L [1]:19066.1 Hz S1L [2]:3437.9 Hz
S1L [3]:3123.7 Hz S1L [4]:2640.4 Hz S1L [5]:4217.2 Hz
Right S1 scintillators normalized by charge
S1L [0]:12926483.000000 S1L [1]:537129290.000000 S1L [2]:96852868.000000
S1L [3]:88000551.000000 S1L [4]:74385376.000000 S1L [5]:118805450.000000
S1R [0]:12400204.000000 S1R [1]:108898510.000000 S1R [2]:97133494.000000
S1R [3]:85753212.000000 S1R [4]:181217910.000000 S1R [5]:49002309.000000
Right arm S2 scintillators
S2 [0]:1.277E+07 S2 [1]:1.571E+07 S2 [2]:2.453E+07 S2 [3]:4.042E+07
S2 [4]:5.418E+07 S2 [5]:5.91E+07 S2 [6]:5.517E+07 S2 [7]:5.817E+07
S2 [8]:5.732E+07 S2 [9]:5.453E+07 S2 [10]:5.555E+07 S2 [11]:5.688E+07
S2 [12]:7.838E+07 S2 [13]:4.867E+07 S2 [14]:3.317E+07 S2 [15]:2.377E+07
S2 [16]:1.278E+07 S2 [17]:1.861E+07 S2 [18]:3.004E+07 S2 [19]:3.975E+07
S2 [20]:5.4E+07 S2 [21]:5.751E+07 S2 [22]:5.623E+07 S2 [23]:6.016E+07
S2 [24]:5.493E+07 S2 [25]:5.719E+07 S2 [26]:5.248E+07 S2 [27]:5.127E+07
S2 [28]:4.759E+07 S2 [29]:4.136E+07 S2 [30]:3.783E+07 S2 [31]:2.234E+07
Right arm S2 scintillators rates
S2 [0]:4341.8 Hz S2 [1]:5344.9 Hz S2 [2]:8342.9 Hz S2 [3]:13749.2 Hz
S2 [4]:18427.2 Hz S2 [5]:20102.8 Hz S2 [6]:18763.9 Hz S2 [7]:19785.9 Hz
S2 [8]:19494.8 Hz S2 [9]:18547.9 Hz S2 [10]:18893.4 Hz S2 [11]:19346.4 Hz
S2 [12]:26660.2 Hz S2 [13]:16552.9 Hz S2 [14]:11282.4 Hz S2 [15]:8085.0 Hz
S2 [16]:4348.0 Hz S2 [17]:6328.9 Hz S2 [18]:10216.5 Hz S2 [19]:13518.8 Hz
S2 [20]:18365.4 Hz S2 [21]:19561.9 Hz S2 [22]:19126.4 Hz S2 [23]:20460.7 Hz
S2 [24]:18681.8 Hz S2 [25]:19452.2 Hz S2 [26]:17850.4 Hz S2 [27]:17438.2 Hz
S2 [28]:16187.5 Hz S2 [29]:14068.5 Hz S2 [30]:12867.3 Hz S2 [31]:7599.5 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:122318220.000000 S2 [ 1]:150577360.000000 S2 [ 2]:235035980.000000
S2 [ 3]:387343300.000000 S2 [ 4]:519129210.000000 S2 [ 5]:566336370.000000
S2 [ 6]:528617120.000000 S2 [ 7]:557407620.000000 S2 [ 8]:549208030.000000
S2 [ 9]:522531860.000000 S2 [10]:532263340.000000 S2 [11]:545026280.000000
S2 [12]:751069750.000000 S2 [13]:466326660.000000 S2 [14]:317846420.000000
S2 [15]:227771440.000000 S2 [16]:122492310.000000 S2 [17]:178297110.000000
S2 [18]:287817850.000000 S2 [19]:380849890.000000 S2 [20]:517389350.000000
S2 [21]:551097560.000000 S2 [22]:538827190.000000 S2 [23]:576419480.000000
S2 [24]:526302960.000000 S2 [25]:548006900.000000 S2 [26]:502881580.000000
S2 [27]:491268690.000000 S2 [28]:456033270.000000 S2 [29]:396336650.000000
S2 [30]:362496480.000000 S2 [31]:214091980.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 121875480.000000
Right arm S2m : 425919340.000000
Left arm S1 scintillators
S1R [0]:7.914E+06 S1R [1]:8.765E+06 S1R [2]:1.128E+07
S1R [3]:8.394E+06 S1R [4]:9.102E+06 S1R [5]:6.705E+06
S1L [0]:7.663E+06 S1L [1]:7.555E+06 S1L [2]:9.644E+06
S1L [3]:9.164E+06 S1L [4]:9.338E+06 S1L [5]:7.215E+06
Left arm S1 scintillators rates
S1R [0]:2691.6 Hz S1R [1]:2981.0 Hz S1R [2]:3835.0 Hz
S1R [3]:2854.9 Hz S1R [4]:3095.7 Hz S1R [5]:2280.6 Hz
S1L [0]:2606.3 Hz S1L [1]:2569.7 Hz S1L [2]:3280.0 Hz
S1L [3]:3117.0 Hz S1L [4]:3176.0 Hz S1L [5]:2454.0 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:75826826.0 S1R [1]:83981185.0 S1R [2]:108038800.0
S1R [3]:80428114.0 S1R [4]:87210731.0 S1R [5]:64250075.0
S1L [0]:73424489.0 S1L [1]:72394765.0 S1L [2]:92404307.0
S1L [3]:87812017.0 S1L [4]:89474954.0 S1L [5]:69133129.0
Left arm S2 scintillators
S2R [0]:2.341E+07 S2R [1]:1.976E+07 S2R [2]:2.551E+07
S2R [3]:3.924E+07 S2R [4]:3.693E+07 S2R [5]:2.697E+07
S2L [0]:4.216E+07 S2L [1]:2.232E+07 S2L [2]:3.154E+07
S2L [3]:2.375E+07 S2L [4]:2.397E+07 S2L [5]:3.039E+07
Left arm S2 scintillators rates
S2R [0]:7963.5 Hz S2R [1]:6719.5 Hz S2R [2]:8677.3 Hz
S2R [3]:13345.6 Hz S2R [4]:12560.9 Hz S2R [5]:9173.6 Hz
S2L [0]:14338.4 Hz S2L [1]:7590.7 Hz S2L [2]:10726.6 Hz
S2L [3]:8077.9 Hz S2L [4]:8152.0 Hz S2L [5]:10337.5 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:224347250.0 S2R [1]:189301320.0 S2R [2]:244455940.0
S2R [3]:375972350.0 S2R [4]:353865930.0 S2R [5]:258437520.0
S2L [0]:403942040.0 S2L [1]:213844760.0 S2L [2]:302188560.0
S2L [3]:227571690.0 S2L [4]:229656740.0 S2L [5]:291226930.0
Left arm Gas Cerenkov
GasC [0]:2.311E+07 GasC [1]:1.723E+07 GasC [2]:1.939E+07
GasC [3]:1.916E+07 GasC [4]:2.037E+07 GasC [5]:1.864E+07
GasC [6]:1.83E+07 GasC [7]:1.853E+07 GasC [8]:1.597E+07
GasC [9]:7.059E+07
Left arm Gas Cerenkov rates
GasC [0]:7858.8 Hz GasC [1]:5861.1 Hz GasC [2]:6596.1 Hz
GasC [3]:6515.5 Hz GasC [4]:6929.6 Hz GasC [5]:6338.4 Hz
GasC [6]:6223.5 Hz GasC [7]:6301.4 Hz GasC [8]:5431.8 Hz
GasC [9]:24009.4 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:221398400.0 GasC [1]:165118880.0 GasC [2]:185826430.0
GasC [3]:183554930.0 GasC [4]:195219580.0 GasC [5]:178564730.0
GasC [6]:175329380.0 GasC [7]:177522710.0 GasC [8]:153025030.0
GasC [9]:676392440.0
Average of detectors sum of detectors charge normalized
Left S1 : 82031615.000000
Left S2 : 276234250.000000
Gas Cerenkov : 231195250.000000
****************************
End-of-run EPICS data for Run Number 3928 at Thu May 31 04:54:46 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 1.86699
Left Arm arm angle : 36.0991
Right Arm D1 momentum : 0.592003
Right Arm arm angle : 63.0391
HALLA:p : 2094.13
HALLA:dpp : 0
Tiefenbach Hall A energy : 2094.13
Left Arm Top VDC Current : 3.07617
Left Arm Bottom VDC Current : 1.07422
Left Arm Q1 momentum : 1.86706
Left Arm Q1 power supply : 1404.65
Left Arm Q1 gauss meter : -0.11848
Left Arm Q2 gauss meter : 0.4241
Left Arm Q2 power supply current : 803.974
Left Arm Q2 momentum : 1.8671
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 628.412
Left Arm D1 momentum : 1.86699
Left Arm D1 NMR : 0.690881
Left Arm Q3 gauss meter : -0.3713
Left Arm Q3 power supply current : 743.376
Left Arm Q3 momentum : 1.86722
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.591998
Right Arm Q1 power supply : 445.144
Right Arm Q1 gauss meter : 0.011279
Right Arm Q2 power supply current : 254.774
Right Arm Q2 momentum : 0.591993
Right Arm Q2 gauss meter : -0.13491
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 203.38
Right Arm D1 momentum : 0.592
Right Arm D1 NMR : 0.219684
Right Arm Q3 power supply current : 235.621
Right Arm Q3 momentum : 0.592149
Right Arm Q3 gauss meter : -0.10625
Right Arm Q3 power supply polarity : enabled