Run Number: 3931
End of Run Comment:
Run_type=4He Production
target_type=Dummy Al 20cm
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=1.867
leftarm_theta=36.099
leftarm_colli=out
rightarm_p=0.5920
rightarm_theta=63.039
rightarm_colli=out
comment_text=40 uA
PRESCALE FACTORS:ps1=76 ps2=7100 ps3=1 ps4=25 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 175461 [+]: 1784 [-]: 1606
TIME [0]: 21.139 mins [+]: 0.217 mins [-]: 0.200 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 1242.96090 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 97.73%
TRIGGER RATES: PRES/REAL
T1[0] : 9.7/733.8 Hz T2[0] : 4.6/32641.6 Hz T3[0] :122.6/122.6 Hz T4[0] : 4.6/115.5 Hz
T5[0] : 3.8/3.8 Hz T6[0] : 4.5/4.5 Hz T7[0] : 0.0/0.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 9.5/720.3 Hz T2[+] : 4.5/32627.2 Hz T3[+] :121.1/121.1 Hz T4[+] : 4.5/112.6 Hz
T5[+] : 3.8/3.8 Hz T6[+] : 4.5/4.5 Hz T7[+] : 0.1/0.1 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 9.6/736.3 Hz T2[-] : 4.6/32764.9 Hz T3[-] :119.4/119.4 Hz T4[-] : 4.7/117.9 Hz
T5[-] : 3.8/3.8 Hz T6[-] : 4.7/4.7 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 12246/930703 T2[0] : 5831/41400149 T3[0] : 155550/155550 T4[0] : 5859/146492
T5[0] : 4784/4784 T6[0] : 5699/5699 T7[0] : 42/42 T8[0] : 19/1298763
T1[+] : 123/9357 T2[+] : 59/423835 T3[+] : 1573/1573 T4[+] : 58/1463
T5[+] : 49/49 T6[+] : 59/59 T7[+] : 1/1 T8[+] : 0/13302
T1[-] : 115/8815 T2[-] : 55/392283 T3[-] : 1429/1429 T4[-] : 56/1412
T5[-] : 46/46 T6[-] : 56/56 T7[-] : 0/0 T8[-] : 0/12260
AVERAGE CURRENT
BCM x1 : 37.2086uA BCM x3 : 37.1885uA BCM x10: 31.4026uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1622 ppm BCM u3 : -1630 ppm BCM u10: -461.6 ppm
BCM d1 : -1605 ppm BCM d3 : -1604 ppm BCM d10: -1374 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.04736 BCM u3 [0]:0.04745 BCM u10[0]:0.03645
BCM u1 [+]:0.0004851 BCM u3 [+]:0.0004859 BCM u10[+]:0.0003124
BCM u1 [-]:0.0004485 BCM u3 [-]:0.0004493 BCM u10[-]:0.0002881
BCM d1 [0]:0.04702 BCM d3 [0]:0.04689 BCM d10[0]:0.04321
BCM d1 [+]:0.0004815 BCM d3 [+]:0.0004802 BCM d10[+]:0.0004425
BCM d1 [-]:0.0004452 BCM d3 [-]:0.000444 BCM d10[-]:0.000409
Right S1 scintillators
S1R [0]:5.996E+04 S1R [1]:3.735E+05 S1R [2]:3.234E+05
S1R [3]:2.752E+05 S1R [4]:5.299E+05 S1R [5]:1.669E+05
Right S1 scintillators rates
S1L [0]:50.8 Hz S1L [1]:863.2 Hz S1L [2]:256.6 Hz
S1L [3]:226.4 Hz S1L [4]:195.1 Hz S1L [5]:256.3 Hz
Right S1 scintillators normalized by charge
S1L [0]:1360077.000000 S1L [1]:23114131.000000 S1L [2]:6870944.700000
S1L [3]:6062613.200000 S1L [4]:5224512.400000 S1L [5]:6862774.000000
S1R [0]:1265870.900000 S1R [1]:7885719.000000 S1R [2]:6828191.000000
S1R [3]:5809869.700000 S1R [4]:11187789.000000 S1R [5]:3523080.700000
Right arm S2 scintillators
S2 [0]:3.022E+06 S2 [1]:2.871E+06 S2 [2]:2.68E+06 S2 [3]:3.363E+06
S2 [4]:3.46E+06 S2 [5]:3.608E+06 S2 [6]:3.134E+06 S2 [7]:3.52E+06
S2 [8]:3.403E+06 S2 [9]:3.242E+06 S2 [10]:3.455E+06 S2 [11]:3.447E+06
S2 [12]:4.663E+06 S2 [13]:3.511E+06 S2 [14]:2.657E+06 S2 [15]:2.418E+06
S2 [16]:3.031E+06 S2 [17]:3.456E+06 S2 [18]:3.721E+06 S2 [19]:3.37E+06
S2 [20]:3.62E+06 S2 [21]:3.627E+06 S2 [22]:3.42E+06 S2 [23]:4.135E+06
S2 [24]:3.27E+06 S2 [25]:3.589E+06 S2 [26]:3.22E+06 S2 [27]:3.248E+06
S2 [28]:2.925E+06 S2 [29]:2.785E+06 S2 [30]:3.137E+06 S2 [31]:2.189E+06
Right arm S2 scintillators rates
S2 [0]:2382.7 Hz S2 [1]:2263.7 Hz S2 [2]:2113.0 Hz S2 [3]:2651.4 Hz
S2 [4]:2728.1 Hz S2 [5]:2844.8 Hz S2 [6]:2470.7 Hz S2 [7]:2775.1 Hz
S2 [8]:2683.1 Hz S2 [9]:2555.8 Hz S2 [10]:2723.7 Hz S2 [11]:2717.4 Hz
S2 [12]:3676.8 Hz S2 [13]:2768.4 Hz S2 [14]:2094.7 Hz S2 [15]:1906.8 Hz
S2 [16]:2389.6 Hz S2 [17]:2724.6 Hz S2 [18]:2933.8 Hz S2 [19]:2657.4 Hz
S2 [20]:2853.8 Hz S2 [21]:2859.6 Hz S2 [22]:2696.2 Hz S2 [23]:3260.6 Hz
S2 [24]:2578.3 Hz S2 [25]:2829.5 Hz S2 [26]:2538.9 Hz S2 [27]:2560.6 Hz
S2 [28]:2306.4 Hz S2 [29]:2196.2 Hz S2 [30]:2473.5 Hz S2 [31]:1725.8 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:63803762.000000 S2 [ 1]:60616357.000000 S2 [ 2]:56583229.000000
S2 [ 3]:71000037.000000 S2 [ 4]:73052831.000000 S2 [ 5]:76177742.000000
S2 [ 6]:66159401.000000 S2 [ 7]:74313107.000000 S2 [ 8]:71847153.000000
S2 [ 9]:68439159.000000 S2 [10]:72935886.000000 S2 [11]:72768059.000000
S2 [12]:98458480.000000 S2 [13]:74132042.000000 S2 [14]:56092647.000000
S2 [15]:51059778.000000 S2 [16]:63989767.000000 S2 [17]:72960820.000000
S2 [18]:78562875.000000 S2 [19]:71161087.000000 S2 [20]:76418873.000000
S2 [21]:76573568.000000 S2 [22]:72198642.000000 S2 [23]:87312600.000000
S2 [24]:69041977.000000 S2 [25]:75768889.000000 S2 [26]:67987890.000000
S2 [27]:68568687.000000 S2 [28]:61760216.000000 S2 [29]:58809529.000000
S2 [30]:66234879.000000 S2 [31]:46213821.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 7166297.800000
Right arm S2m : 69406372.000000
Left arm S1 scintillators
S1R [0]:1.981E+06 S1R [1]:1.951E+06 S1R [2]:2.256E+06
S1R [3]:1.551E+06 S1R [4]:1.601E+06 S1R [5]:1.317E+06
S1L [0]:1.912E+06 S1L [1]:1.715E+06 S1L [2]:1.952E+06
S1L [3]:1.708E+06 S1L [4]:1.644E+06 S1L [5]:1.429E+06
Left arm S1 scintillators rates
S1R [0]:1561.6 Hz S1R [1]:1538.0 Hz S1R [2]:1778.4 Hz
S1R [3]:1222.8 Hz S1R [4]:1262.6 Hz S1R [5]:1038.0 Hz
S1L [0]:1507.3 Hz S1L [1]:1352.1 Hz S1L [2]:1539.0 Hz
S1L [3]:1347.0 Hz S1L [4]:1295.9 Hz S1L [5]:1126.3 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:41815438.0 S1R [1]:41185807.0 S1R [2]:47622563.0
S1R [3]:32744437.0 S1R [4]:33808869.0 S1R [5]:27795765.0
S1L [0]:40362506.0 S1L [1]:36207303.0 S1L [2]:41212642.0
S1L [3]:36069879.0 S1L [4]:34701673.0 S1L [5]:30161454.0
Left arm S2 scintillators
S2R [0]:5.826E+06 S2R [1]:4.65E+06 S2R [2]:5.535E+06
S2R [3]:8.265E+06 S2R [4]:7.569E+06 S2R [5]:5.884E+06
S2L [0]:1.039E+07 S2L [1]:5.125E+06 S2L [2]:6.752E+06
S2L [3]:4.836E+06 S2L [4]:4.805E+06 S2L [5]:6.544E+06
Left arm S2 scintillators rates
S2R [0]:4593.4 Hz S2R [1]:3666.1 Hz S2R [2]:4363.8 Hz
S2R [3]:6516.3 Hz S2R [4]:5968.1 Hz S2R [5]:4639.6 Hz
S2L [0]:8195.9 Hz S2L [1]:4041.0 Hz S2L [2]:5323.5 Hz
S2L [3]:3813.1 Hz S2L [4]:3788.1 Hz S2L [5]:5159.5 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:123003310.0 S2R [1]:98170013.0 S2R [2]:116854510.0
S2R [3]:174493460.0 S2R [4]:159813070.0 S2R [5]:124239010.0
S2L [0]:219469340.0 S2L [1]:108210000.0 S2L [2]:142554010.0
S2L [3]:102106950.0 S2L [4]:101439190.0 S2L [5]:138162580.0
Left arm Gas Cerenkov
GasC [0]:6.477E+06 GasC [1]:4.779E+06 GasC [2]:5.387E+06
GasC [3]:5.348E+06 GasC [4]:5.796E+06 GasC [5]:5.22E+06
GasC [6]:5.147E+06 GasC [7]:5.26E+06 GasC [8]:4.579E+06
GasC [9]:4.243E+07
Left arm Gas Cerenkov rates
GasC [0]:5106.4 Hz GasC [1]:3767.7 Hz GasC [2]:4247.1 Hz
GasC [3]:4216.3 Hz GasC [4]:4569.6 Hz GasC [5]:4115.6 Hz
GasC [6]:4058.0 Hz GasC [7]:4146.8 Hz GasC [8]:3610.2 Hz
GasC [9]:33454.8 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:136739820.0 GasC [1]:100891690.0 GasC [2]:113729460.0
GasC [3]:112903830.0 GasC [4]:122366400.0 GasC [5]:110207410.0
GasC [6]:108664520.0 GasC [7]:111044080.0 GasC [8]:96674771.0
GasC [9]:895855980.0
Average of detectors sum of detectors charge normalized
Left S1 : 36974029.000000
Left S2 : 134042960.000000
Gas Cerenkov : 190907800.000000
****************************
End-of-run EPICS data for Run Number 3931 at Thu May 31 06:54:51 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 1.86699
Left Arm arm angle : 36.0991
Right Arm D1 momentum : 0.592002
Right Arm arm angle : 63.0391
HALLA:p : 2094.08
HALLA:dpp : -2.45099e-05
Tiefenbach Hall A energy : 2094.07
Left Arm Top VDC Current : 2.44141
Left Arm Bottom VDC Current : 0.195312
Left Arm Q1 momentum : 1.86706
Left Arm Q1 power supply : 1404.65
Left Arm Q1 gauss meter : -0.11848
Left Arm Q2 gauss meter : 0.4241
Left Arm Q2 power supply current : 804.059
Left Arm Q2 momentum : 1.8673
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 628.41
Left Arm D1 momentum : 1.86699
Left Arm D1 NMR : 0.690882
Left Arm Q3 gauss meter : -0.3713
Left Arm Q3 power supply current : 743.399
Left Arm Q3 momentum : 1.86728
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.591998
Right Arm Q1 power supply : 445.144
Right Arm Q1 gauss meter : 0.011282
Right Arm Q2 power supply current : 254.976
Right Arm Q2 momentum : 0.592462
Right Arm Q2 gauss meter : -0.1349
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 203.388
Right Arm D1 momentum : 0.592003
Right Arm D1 NMR : 0.219685
Right Arm Q3 power supply current : 235.638
Right Arm Q3 momentum : 0.592192
Right Arm Q3 gauss meter : -0.10626
Right Arm Q3 power supply polarity : enabled