Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name atrig

    Log entry time 06:57:26 on May 31, 2007

    Entry number 203809

    keyword=Trigger-Download
     
    Download of trigger at Thu May 31 06:57:26 EDT 2007
    Database directory = /adaqfs/halla/atrig/trigger
    Momentum of Left Spectrometer  1919.00 MeV/c
    Momentum of Right Spectrometer   970.70 MeV/c
    Delay assumed 252.3 nsec
    PID of Left Spectrometer: 
      Electron
    PID of Right Spectrometer: 
      Helium-4
    
    -----------------------
    Detailed Dump of Data:
    
    
    0) s1L_disc LeCroy4413 
    crate: 1   slot: 2  -- display-X 1 -Y 1 
    Descriminator setting  45 mV 
    Module state: none
    -----------------------
    1) s1L_delay1 LeCroy4418/32 
    crate: 1   slot: 4  -- display-X 2 -Y 1 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    2) s1L_logic LeCroy4516 
    crate: 1   slot: 7  -- display-X 4 -Y 1 
    Module state: and-or
    -----------------------
    3) s1L_delay2 LeCroy4418/32 
    crate: 1   slot: 8  -- display-X 4 -Y 2 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 4 [3]: 15 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    4) s2L_disc LeCroy4413 
    crate: 1   slot: 12  -- display-X 1 -Y 14 
    Descriminator setting  45 mV 
    Module state: none
    -----------------------
    5) s2L_delay1 LeCroy4418/32 
    crate: 1   slot: 13  -- display-X 2 -Y 14 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    6) s2L_delay2 LeCroy4418/32 
    crate: 1   slot: 21  -- display-X 2 -Y 4 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 9 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    7) s2L_logic LeCroy4516 
    crate: 1   slot: 15  -- display-X 4 -Y 3 
    Module state: and-or
    -----------------------
    8) cherL_disc LeCroy4413 
    crate: 2   slot: 7  -- display-X 1 -Y 9 
    Descriminator setting  50 mV 
    Module state: none
    -----------------------
    9) cherL_delay LeCroy4418/32 
    crate: 2   slot: 8  -- display-X 2 -Y 9 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    10) aro2L_r_disc LeCroy3412 
    crate: 2   slot: 13  -- display-X 1 -Y 11 
    Module state: none
    -----------------------
    11) aro2L_r_delay LeCroy4418/16 
    crate: 2   slot: 14  -- display-X 2 -Y 11 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    12) mlogL_mlu LeCroy2373 
    crate: 2   slot: 16  -- display-X 2 -Y 5 
    Module state: pulse
    MLU file 1 mlu2_2of3_t2t4.data 
    -----------------------
    13) Ldelay1 LeCroy4518/300 
    crate: 2   slot: 17  -- display-X 4 -Y 5 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 6 [3]: 0 [4]: 0 [5]: 3 [6]: 0 [7]: 11 
    [8]: 3 [9]: 0 [10]: 0 [11]: 3 [12]: 15 [13]: 15 [14]: 15 [15]: 5 
    Module state: none
    -----------------------
    14) Ldelay2 LeCroy4518/300 
    crate: 2   slot: 18  -- display-X 5 -Y 5 
    Delay settings (in units of leastcount):
    [0]: 15 [1]: 15 [2]: 15 [3]: 0 [4]: 0 [5]: 14 [6]: 15 [7]: 3 
    [8]: 7 [9]: 15 [10]: 3 [11]: 0 [12]: 0 [13]: 7 [14]: 15 [15]: 0 
    Module state: none
    -----------------------
    15) edtL_l_edtm EDTM 
    crate: 1   slot: 1  -- display-X 1 -Y 2 
    Module state: none
    -----------------------
    16) edtL_r_edtm EDTM 
    crate: 1   slot: 10  -- display-X 1 -Y 13 
    Module state: none
    -----------------------
    0) s1R_disc LeCroy4413 
    crate: 1   slot: 2  -- display-X 1 -Y 1 
    Descriminator setting  45 mV 
    Module state: none
    -----------------------
    1) s1R_delay1 LeCroy4418/32 
    crate: 1   slot: 4  -- display-X 2 -Y 1 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    2) s1R_logic LeCroy4516 
    crate: 1   slot: 7  -- display-X 3 -Y 2 
    Module state: and-or
    -----------------------
    3) s1R_delay2 LeCroy4418/32 
    crate: 1   slot: 8  -- display-X 4 -Y 2 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    4) Rcoin_log LeCroy4516 
    crate: 1   slot: 14  -- display-X 5 -Y 2 
    Module state: and-or
    -----------------------
    5) stbR_delay LeCroy4418/32 
    crate: 1   slot: 21  -- display-X 3 -Y 3 
    Delay settings (in units of leastcount):
    [0]: 15 [1]: 15 [2]: 15 [3]: 15 [4]: 15 [5]: 15 [6]: 15 [7]: 15 
    [8]: 6 [9]: 6 [10]: 6 [11]: 6 [12]: 6 [13]: 6 [14]: 6 [15]: 0 
    Module state: none
    -----------------------
    6) stbR_logic LeCroy4564 
    crate: 1   slot: 23  -- display-X 5 -Y 3 
    Module state: none
    -----------------------
    7) cherR_disc LeCroy4413 
    crate: 2   slot: 6  -- display-X 1 -Y 7 
    Descriminator setting  30 mV 
    Module state: none
    -----------------------
    8) cherR_delay LeCroy4418/32 
    crate: 2   slot: 7  -- display-X 2 -Y 7 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0 
    [8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0 
    Module state: none
    -----------------------
    9) mlogR_mlu LeCroy2373 
    crate: 2   slot: 9  -- display-X 2 -Y 5 
    Module state: pulse
    MLU file 1 mlu2_t2t4_ors1s2.data 
    -----------------------
    10) Rdelay1 LeCroy4518/300 
    crate: 2   slot: 11  -- display-X 4 -Y 5 
    Delay settings (in units of leastcount):
    [0]: 0 [1]: 0 [2]: 9 [3]: 0 [4]: 7 [5]: 0 [6]: 0 [7]: 0 
    [8]: 10 [9]: 0 [10]: 0 [11]: 0 [12]: 5 [13]: 2 [14]: 2 [15]: 5 
    Module state: none
    -----------------------
    11) Rdelay2 LeCroy4518/300 
    crate: 2   slot: 12  -- display-X 5 -Y 5 
    Delay settings (in units of leastcount):
    [0]: 15 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 15 [6]: 15 [7]: 13 
    [8]: 0 [9]: 15 [10]: 15 [11]: 15 [12]: 15 [13]: 15 [14]: 10 [15]: 9 
    Module state: none
    -----------------------