keyword=End_of_Run_3932
****************************
Run Number: 3932
End of Run Comment:
Run_type=4He Production
target_type=Dummy Al 20cm
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=1.919
leftarm_theta=30.51
leftarm_colli=out
rightarm_p=0.4853
rightarm_theta=66.941
rightarm_colli=out
comment_text=40 uA
PRESCALE FACTORS:ps1=50 ps2=7000 ps3=1 ps4=25 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 136741 [+]: 1414 [-]: 1303
TIME [0]: 13.971 mins [+]: 0.141 mins [-]: 0.134 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 821.51630 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 97.35%
TRIGGER RATES: PRES/REAL
T1[0] : 8.7/436.7 Hz T2[0] : 4.3/30310.0 Hz T3[0] :149.8/149.8 Hz T4[0] : 4.6/115.4 Hz
T5[0] : 3.8/3.8 Hz T6[0] : 4.5/4.5 Hz T7[0] : 0.0/0.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 8.9/445.7 Hz T2[+] : 4.4/30663.4 Hz T3[+] :154.0/154.0 Hz T4[+] : 4.7/119.2 Hz
T5[+] : 3.7/3.7 Hz T6[+] : 4.4/4.4 Hz T7[+] : 0.2/0.2 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 8.5/424.6 Hz T2[-] : 4.2/29953.0 Hz T3[-] :148.6/148.6 Hz T4[-] : 4.5/114.1 Hz
T5[-] : 3.9/3.9 Hz T6[-] : 5.1/5.1 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 7321/366093 T2[0] : 3629/25408193 T3[0] : 125614/125614 T4[0] : 3869/96748
T5[0] : 3151/3151 T6[0] : 3780/3780 T7[0] : 21/21 T8[0] : 13/858397
T1[+] : 75/3772 T2[+] : 37/259501 T3[+] : 1303/1303 T4[+] : 40/1009
T5[+] : 31/31 T6[+] : 37/37 T7[+] : 2/2 T8[+] : 0/8666
T1[-] : 68/3412 T2[-] : 34/240677 T3[-] : 1194/1194 T4[-] : 36/917
T5[-] : 31/31 T6[-] : 41/41 T7[-] : 0/0 T8[-] : 0/8228
AVERAGE CURRENT
BCM x1 : 35.2132uA BCM x3 : 35.1897uA BCM x10: 30.6154uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.344E+04 ppm BCM u3 :1.351E+04 ppm BCM u10:1.871E+04 ppm
BCM d1 :1.331E+04 ppm BCM d3 : 1.33E+04 ppm BCM d10:1.358E+04 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.02962 BCM u3 [0]:0.02967 BCM u10[0]:0.02426
BCM u1 [+]:0.0003026 BCM u3 [+]:0.000303 BCM u10[+]:0.0002137
BCM u1 [-]:0.0002796 BCM u3 [-]:0.00028 BCM u10[-]:0.0001954
BCM d1 [0]:0.02941 BCM d3 [0]:0.02933 BCM d10[0]:0.02707
BCM d1 [+]:0.0003004 BCM d3 [+]:0.0002995 BCM d10[+]:0.0002765
BCM d1 [-]:0.0002777 BCM d3 [-]:0.0002769 BCM d10[-]:0.0002555
Right S1 scintillators
S1R [0]:2.19E+04 S1R [1]:1.608E+05 S1R [2]:1.316E+05
S1R [3]:1.139E+05 S1R [4]:2.218E+05 S1R [5]:6.654E+04
Right S1 scintillators rates
S1L [0]:28.6 Hz S1L [1]:845.4 Hz S1L [2]:163.2 Hz
S1L [3]:139.0 Hz S1L [4]:124.1 Hz S1L [5]:155.3 Hz
Right S1 scintillators normalized by charge
S1L [0]:809107.620000 S1L [1]:23924510.000000 S1L [2]:4617429.500000
S1L [3]:3933563.400000 S1L [4]:3510746.600000 S1L [5]:4396079.400000
S1R [0]:739228.920000 S1R [1]:5429339.000000 S1R [2]:4443745.400000
S1R [3]:3846299.400000 S1R [4]:7486102.200000 S1R [5]:2246313.400000
Right arm S2 scintillators
S2 [0]:1.821E+06 S2 [1]:1.734E+06 S2 [2]:1.623E+06 S2 [3]:2.039E+06
S2 [4]:2.111E+06 S2 [5]:2.197E+06 S2 [6]:1.919E+06 S2 [7]:2.151E+06
S2 [8]:2.083E+06 S2 [9]:1.986E+06 S2 [10]:2.117E+06 S2 [11]:2.13E+06
S2 [12]:2.935E+06 S2 [13]:2.152E+06 S2 [14]:1.624E+06 S2 [15]:1.468E+06
S2 [16]:1.827E+06 S2 [17]:2.089E+06 S2 [18]:2.249E+06 S2 [19]:2.045E+06
S2 [20]:2.208E+06 S2 [21]:2.204E+06 S2 [22]:2.082E+06 S2 [23]:2.516E+06
S2 [24]:2.004E+06 S2 [25]:2.193E+06 S2 [26]:1.98E+06 S2 [27]:1.991E+06
S2 [28]:1.809E+06 S2 [29]:1.716E+06 S2 [30]:1.918E+06 S2 [31]:1.334E+06
Right arm S2 scintillators rates
S2 [0]:2172.5 Hz S2 [1]:2068.9 Hz S2 [2]:1935.7 Hz S2 [3]:2432.2 Hz
S2 [4]:2518.7 Hz S2 [5]:2620.6 Hz S2 [6]:2288.8 Hz S2 [7]:2565.4 Hz
S2 [8]:2484.6 Hz S2 [9]:2369.1 Hz S2 [10]:2525.4 Hz S2 [11]:2541.0 Hz
S2 [12]:3501.7 Hz S2 [13]:2566.8 Hz S2 [14]:1937.7 Hz S2 [15]:1750.9 Hz
S2 [16]:2179.3 Hz S2 [17]:2491.5 Hz S2 [18]:2683.0 Hz S2 [19]:2440.0 Hz
S2 [20]:2633.6 Hz S2 [21]:2629.2 Hz S2 [22]:2483.3 Hz S2 [23]:3001.6 Hz
S2 [24]:2390.3 Hz S2 [25]:2615.9 Hz S2 [26]:2361.8 Hz S2 [27]:2374.8 Hz
S2 [28]:2158.5 Hz S2 [29]:2047.3 Hz S2 [30]:2287.6 Hz S2 [31]:1591.6 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:61478980.000000 S2 [ 1]:58546572.000000 S2 [ 2]:54777409.000000
S2 [ 3]:68828768.000000 S2 [ 4]:71274826.000000 S2 [ 5]:74157610.000000
S2 [ 6]:64770807.000000 S2 [ 7]:72596310.000000 S2 [ 8]:70309791.000000
S2 [ 9]:67041460.000000 S2 [10]:71464174.000000 S2 [11]:71907718.000000
S2 [12]:99091411.000000 S2 [13]:72635537.000000 S2 [14]:54833583.000000
S2 [15]:49549132.000000 S2 [16]:61669441.000000 S2 [17]:70504878.000000
S2 [18]:75924596.000000 S2 [19]:69047113.000000 S2 [20]:74527359.000000
S2 [21]:74402658.000000 S2 [22]:70272725.000000 S2 [23]:84940130.000000
S2 [24]:67640391.000000 S2 [25]:74026899.000000 S2 [26]:66834760.000000
S2 [27]:67202991.000000 S2 [28]:61082629.000000 S2 [29]:57935218.000000
S2 [30]:64734855.000000 S2 [31]:45039930.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 5448538.800000
Right arm S2m : 67782834.000000
Left arm S1 scintillators
S1R [0]:1.248E+06 S1R [1]:1.248E+06 S1R [2]:1.461E+06
S1R [3]:1.025E+06 S1R [4]:1.074E+06 S1R [5]:8.714E+05
S1L [0]:1.206E+06 S1L [1]:1.103E+06 S1L [2]:1.276E+06
S1L [3]:1.133E+06 S1L [4]:1.095E+06 S1L [5]:9.444E+05
Left arm S1 scintillators rates
S1R [0]:1488.4 Hz S1R [1]:1488.8 Hz S1R [2]:1742.5 Hz
S1R [3]:1222.7 Hz S1R [4]:1281.3 Hz S1R [5]:1039.5 Hz
S1L [0]:1439.1 Hz S1L [1]:1315.7 Hz S1L [2]:1522.2 Hz
S1L [3]:1351.8 Hz S1L [4]:1306.2 Hz S1L [5]:1126.6 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:42119574.0 S1R [1]:42130647.0 S1R [2]:49310363.0
S1R [3]:34601166.0 S1R [4]:36257494.0 S1R [5]:29415187.0
S1L [0]:40724600.0 S1L [1]:37231981.0 S1L [2]:43075427.0
S1L [3]:38254269.0 S1L [4]:36963269.0 S1L [5]:31881467.0
Left arm S2 scintillators
S2R [0]:3.626E+06 S2R [1]:2.921E+06 S2R [2]:3.536E+06
S2R [3]:5.371E+06 S2R [4]:4.924E+06 S2R [5]:3.814E+06
S2L [0]:6.477E+06 S2L [1]:3.206E+06 S2L [2]:4.282E+06
S2L [3]:3.102E+06 S2L [4]:3.094E+06 S2L [5]:4.234E+06
Left arm S2 scintillators rates
S2R [0]:4326.1 Hz S2R [1]:3484.5 Hz S2R [2]:4218.6 Hz
S2R [3]:6406.7 Hz S2R [4]:5874.2 Hz S2R [5]:4550.3 Hz
S2L [0]:7726.2 Hz S2L [1]:3824.0 Hz S2L [2]:5108.3 Hz
S2L [3]:3700.0 Hz S2L [4]:3691.4 Hz S2L [5]:5051.3 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:122422120.0 S2R [1]:98605265.0 S2R [2]:119379430.0
S2R [3]:181300030.0 S2R [4]:166231920.0 S2R [5]:128765050.0
S2L [0]:218638920.0 S2L [1]:108214190.0 S2L [2]:144557570.0
S2L [3]:104703720.0 S2L [4]:104460800.0 S2L [5]:142943030.0
Left arm Gas Cerenkov
GasC [0]:4.173E+06 GasC [1]:3.098E+06 GasC [2]:3.497E+06
GasC [3]:3.461E+06 GasC [4]:3.771E+06 GasC [5]:3.392E+06
GasC [6]:3.355E+06 GasC [7]:3.439E+06 GasC [8]:2.997E+06
GasC [9]:1.965E+07
Left arm Gas Cerenkov rates
GasC [0]:4978.3 Hz GasC [1]:3696.0 Hz GasC [2]:4171.8 Hz
GasC [3]:4128.9 Hz GasC [4]:4498.6 Hz GasC [5]:4046.7 Hz
GasC [6]:4001.9 Hz GasC [7]:4102.9 Hz GasC [8]:3575.7 Hz
GasC [9]:23444.4 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:140877760.0 GasC [1]:104591640.0 GasC [2]:118054330.0
GasC [3]:116841920.0 GasC [4]:127302490.0 GasC [5]:114514960.0
GasC [6]:113246950.0 GasC [7]:116106270.0 GasC [8]:101186930.0
GasC [9]:663441580.0
Average of detectors sum of detectors charge normalized
Left S1 : 38497120.000000
Left S2 : 136685170.000000
Gas Cerenkov : 171616480.000000
****************************
End-of-run EPICS data for Run Number 3932 at Thu May 31 07:48:53 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 1.91901
Left Arm arm angle : 30.51
Right Arm D1 momentum : 0.485293
Right Arm arm angle : 66.9405
HALLA:p : 2094.1
HALLA:dpp : -1.33464e-05
Tiefenbach Hall A energy : 2094.1
Left Arm Top VDC Current : 4.98047
Left Arm Bottom VDC Current : -1.80664
Left Arm Q1 momentum : 1.91902
Left Arm Q1 power supply : 1443.74
Left Arm Q1 gauss meter : -0.12176
Left Arm Q2 gauss meter : 0.4358
Left Arm Q2 power supply current : 826.462
Left Arm Q2 momentum : 1.91933
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 647.191
Left Arm D1 momentum : 1.91901
Left Arm D1 NMR : 0.710117
Left Arm Q3 gauss meter : -0.3816
Left Arm Q3 power supply current : 764.078
Left Arm Q3 momentum : 1.91922
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.485317
Right Arm Q1 power supply : 364.927
Right Arm Q1 gauss meter : 0.009293
Right Arm Q2 power supply current : 208.897
Right Arm Q2 momentum : 0.485393
Right Arm Q2 gauss meter : -0.11074
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 164.999
Right Arm D1 momentum : 0.485292
Right Arm D1 NMR : 0.180086
Right Arm Q3 power supply current : 193.104
Right Arm Q3 momentum : 0.485297
Right Arm Q3 gauss meter : -0.08723
Right Arm Q3 power supply polarity : enabled